Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2014 / Cilt: 29 - Sayı: 3

DETERMINATION AND REMOVAL OF COPPER IONS (CU2+) IN THE WASTE ELECTROLYTE IN AN ELECTROCHEMICAL MACHINING APPLICATION

Pages
487–494
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Purification of the electrolyte, contaminated with copper ions, was achieved at 40 % as a result of treatment with the zeolite for two hours, at 90 % as a result of filtering three times using the paper filters, and at 100 % after treatment with the Lewatit TP 207 resin.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Water treatment methods, as part of the peripheral units of a novel electrochemical machining device, were investigated with the aim of preparing the electrolyte, which was contaminated with heavy metal ions after machining of copper work pieces, for refeeding back to the system.
📊
Key Findings & Data:As the ion-exchanger, a paper filter was used in the first step, a natural zeolite with wide reserves in Turkey was used in the second step, and a polymer based cation exchange Lewatit TP 207 resin was used in the final step.
💡
Conclusion & Impact:Purification of the electrolyte, contaminated with copper ions, was achieved at 40 % as a result of treatment with the zeolite for two hours, at 90 % as a result of filtering three times using the paper filters, and at 100 % after treatment with the Lewatit TP 207 resin.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Water treatment methods, as part of the peripheral units of a novel electrochemical machining device, were investigated with the aim of preparing the electrolyte, which was contaminated with heavy metal ions after machining of copper work pieces, for refeeding back to the system. Electrochemical machining (ECM) depends on machining the surface of a metal piece by ionization and removal of metal ions from the work area via the electrolyte. Removal of heavy metal ions in industrial waters and treatment of these waters for reuse is crucial in terms of increasing system efficiency and protecting environmental health. In this study, the ion exchange method was selected and a three-step application is proposed for the treatment of the electrolyte contaminated with copper ions after ECM. As the ion-exchanger, a paper filter was used in the first step, a natural zeolite with wide reserves in Turkey was used in the second step, and a polymer based cation exchange Lewatit TP 207 resin was used in the final step. Purification of the electrolyte, contaminated with copper ions, was achieved at 40 % as a result of treatment with the zeolite for two hours, at 90 % as a result of filtering three times using the paper filters, and at 100 % after treatment with the Lewatit TP 207 resin.

🔖

Cite This Article

ÖNEL, S., ERGİN, G. (2022). DETERMINATION AND REMOVAL OF COPPER IONS (CU2+) IN THE WASTE ELECTROLYTE IN AN ELECTROCHEMICAL MACHINING APPLICATION. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 29 - Sayı: 3, 487–494. https://ajindex.com/articles/523674

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Minczewski, J., Chwastowska, J. ve Dybczynski, D., Separation andPreconcentration Methods, in Inorganic Trace Analysis, E. Horwood, Chichester, 1982
  2. Mizuike, A., Enrichment Techniques for Inorganic Trace Analysis, Springer, Berlin, 1981
  3. Ivanova, E., Benkhedda, K. ve Adams, F., "Determination of Copper, Manganese and Nickel in Biological Samples and Sea-Water by Flow Injection On-line Sorption Preconcentration in a Knotted Reactor Coupled with Electrothermal Atomic Absorption Spectrometry", J. Anal. At. Spect., Cilt 13, 527–531, 1998
  4. Yeager, H. L. ve Steck, A., "Ion-Exchange Selectivity and Metal Ion Separations with a Perfluorinated Cation-Exchange Polymer", Analytical Chemistry, Cilt 51, No 7, 862-865, 1979
  5. Bruhn, C.G., Vilches, C. ve Cid, H.J., "Optimization of Flame Atomic Absorption Spectrometry with Preconcentration by FlowInjection On-line Sorbent Extraction of Cadmium and Lead in Biological Materials", Boletin Soc. Chilena Quimica, Cilt 44, 321–335, 1999
  6. Divrikli, U., Soylak, M. ve Elci, L., "Determination of Chromium by Atomic Absorption Spectrometry Following Coprecipitation with Cerium (IV) Hydroxide", 3rd Mediterranean Basin Conference on Analytical Chemistry, Antalya-Turkey, 145, 4–9 Haziran 2000
  7. Blöcher, C., Dorda, J., Mavrov, V., Chmiel, H., Lazaridis, N.K. ve Matis, K.A., "Hybrid flotationmembrane filtration process for the removal of heavy metal ions from wastewater", Water Research, Cilt 37, 4018-4026, 2003
  8. Soylak, M., Saracoglu, S., Elci, L. ve Dogan, M., "Determination of Trace Metals Ions in Seawater by Atomic Absorption Spectrometry After Separation/Preconcentration with Calmagite on Amberlite XAD-1180", Intern. J. Environ. Anal. Chem., Cilt 82, No 4, 225–231, 2002
  9. Soylak, M. ve Elci, L., "Preconcentration and Separation of Trace Metal Ions from Sea Water Samples by Sorption on Amberlite XAD-16 after Complexation with Sodium Diethyl Dithiocarbamate", Intern. J. Environ. Anal. Chem.,Cilt 66, No 1, 51-59, 1997
  10. Bag, H., Elci, A. ve Elci, L., "Determination of Lead, Iron, Manganese and Zinc in Sea Water Samples by Atomic Absorption Spectrometry after Preconcentration with Chromosorb 105", Eurasian Journal of Analytical Chemistry, Cilt 1, No 1, 42-54, 2006
  11. Narin, İ., Soylak M., Elci, L., Dogan, M., "Separation and Enrichment of Chromium, Copper, Nickel and Lead in Surface Seawater Samples on a Column Filled with Amberlite XAD-2000", Analytical Letters, Cilt 34, No 11, 1935–1947, 2001
  12. Babel,