Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2016 / Cilt: 31 - Sayı: 4

Thermodynamic analysis of a refrigeration system with double evaporators and ejector

Çift buharlaştırıcılı ve ejektörlü bir soğutma sisteminin termodinamik analizi

Pages
1039–1047
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The analyses showed that COP improvements of the proposed system by using ejector as an expansion device were approximately 15% for R134a and about 17% for R1234yf, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, theoretical investigations of double evaporator refrigeration system and with adding an ejector to the current system were carried out using energy and momentum equations.
📊
Key Findings & Data:The relative increase in COP with respect to the conventional double evaporator refrigeration system was analyzed in terms of condenser and evaporator temperatures.
💡
Conclusion & Impact:The analyses showed that COP improvements of the proposed system by using ejector as an expansion device were approximately 15% for R134a and about 17% for R1234yf, respectively.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, theoretical investigations of double evaporator refrigeration system and with adding an ejector to the current system were carried out using energy and momentum equations. The relative increase in COP with respect to the conventional double evaporator refrigeration system was analyzed in terms of condenser and evaporator temperatures. Also exergy analyses of systems were examined and results were showed graphically. In the study, R134a and its potential substitute R1234yf were used. The analyses showed that COP improvements of the proposed system by using ejector as an expansion device were approximately 15% for R134a and about 17% for R1234yf, respectively.

Özet

Bu çalışmada, iki buharlaştırıcılı buhar sıkıştırmalı klasik soğutma sisteminin ve bu sistemin ejektörlü hale getirilmesi ile oluşturulan yeni sistemin termodinamik analizi enerji ve momentum denklemleri kullanılarak yapılmıştır. Çalışmada soğutucu akışkan olarak R134a ve bu soğutucu akışkana alternatif olarak geliştirilen R1234yf kullanılmıştır. Farklı yoğuşturucu ve buharlaştırıcı sıcaklıklarında ejektörlü soğutma sistemi etkinliğinin iki buharlaştırıcılı soğutma sistemi etkinliğine göre artışı analiz edilmiştir. Ayrıca her bir sistemin ekserji analizi yapılmış olup sonuçlar grafikler halinde verilmiştir. Yapılan analizlerde ejektörlü soğutma sisteminde elde edilen soğutma etkinliğinin, iki buharlaştırıcılı sistemin soğutma etkinliğinden R134a için %15 ve R1234yf için ise %17 civarında daha fazla olduğu görülmüştür.

🔖

Cite This Article

ERDİNÇ, M. T., ÜNAL, Ş., KUTLU, Ç. (2022). Thermodynamic analysis of a refrigeration system with double evaporators and ejector. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 31 - Sayı: 4, 1039–1047. https://ajindex.com/articles/523609

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Demir V., Gunhan T., Sencan S.A., Ekren O., Bilgen H., Erek, A., Experimental investigation of cooling performance of milk cooling tank with the vapor compressed and solar absorption (LiCl-H2O) cooling system, Journal of the Faculty of Engineering and Architecture of Gazi University, 31 (1), 29-37, 2016.
  2. Aktaş M., Gönen E., Bay leaves drying in a humidity controlled heat pump dryer, Journal of the Faculty of Engineering and Architecture of Gazi University, 29 (2), 433-441, 2014.
  3. Bolaji B.O., Huan Z., Ozone depletion and global warming: Case for the use of natural refrigerant, Renewable and Sustainable Energy Reviews, 18, 49- 54, 2013.
  4. Park K.J., Seo T., Jung D., Performance of alternative refrigerants for residential air-conditioning applications, Applied Energy, 84 (10), 985-991, 2007.
  5. Esen D.Ö., Hoşöz M., Experimental performance analysis of an automobile air conditioning system using refrigerants R12 and R134a, Journal of the Faculty of Engineering and Architecture of Gazi University, 21 (4), 703-709, 2006. Council Directive 2006/40/EC, Off. J. Eur. Communities, 17 May, 2006.
  6. Araz M., Güngör A., Hepbaşlı A., Düşük küresel ısınma potansiyeline sahip soğutucu akışkanların soğutma uygulamalarındaki kullanımının değerlendirilmesi, 11. Ulusal Tesisat Mühendisliği Kongresi, İzmir-Türkiye, 575-604, 17-20 Nisan, 2013.
  7. Minor B., Spatz M., HFO-1234yf low GWP refrigerant update, International Refrigeration and Air Conditioning Conference, Purdue, 2349, 1-8, 14-17 July, 2008.
  8. Zilio C., Brown J.S., Schiochet G., Cavallini A., The refrigerant R1234yf in air conditioning systems, Energy, 36 (10), 6110-6120, 2011.
  9. Jarall S., Study of refrigeration system with HFO- 1234yf as a working fluid, International Journal of Refrigeration, 35 (6), 1668-1677, 2012.
  10. Özgür A.E., Kabul A., Kizilkan Ö., Exergy analysis of refrigeration systems using an alternative refrigerant (hfo-1234yf) to R134a, International Journal of Low Carbon Technologies, 9 (1), 56-62, 2012.
  11. Özgür A.E., Theoretical investigation of vapor compression cooling cycle using HFO-1234yf and HFO-1234ze, Journal of the Faculty of Engineering and Architecture of Gazi University, 28 (3), 465-472, 2013.
  12. Col D.D., Torresin D., Cavallini A., Heat transfer and pressure drop during condensation of the low GWP refrigerant R1234yf, International Journal of Refrigeration, 33 (7),1307-1318, 2010.
  13. Jarahnejad M., New low GWP synthetic refrigerants, Master of Science Thesis, KTH School of Industrial Engineering and Management Ener