Polyethylene wearing is a common issue but metal wearing and metallosis are rare cases.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Patient suffering from pain and color change in her knee 10 years after a total knee replacement diagnosed as metallosis due to failed total knee replacement (TKR).
📊
Key Findings & Data:Beginning: prosthesis fail and implant wearing is a well known and good identified subjects in arthroplasty surgeries.
💡
Conclusion & Impact:Polyethylene wearing is a common issue but metal wearing and metallosis are rare cases.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Patient suffering from pain and color change in her knee 10 years after a total knee replacement diagnosed as metallosis due to failed total knee replacement (TKR). Beginning: prosthesis fail and implant wearing is a well known and good identified subjects in arthroplasty surgeries. Polyethylene wearing is a common issue but metal wearing and metallosis are rare cases.

Özet

10 yıl önce yapılan total diz protezini takiben ağrı ve ciltte renk değişikliği ile polikliniğe başvuran hastada mevcut protezlerin olağanüstü aşınması sonucu oluşan metalloz bulgusu bildirilmesi amaçlanmıştır

🔖

Cite This Article

MORADİ, R., CENGİZ, B., FRİK, S., IŞİK, M. (2022). Metallosis following to neglected failed total knee replacement. Dicle Tıp Dergisi, Cilt: 45 - Sayı: 3, 353–355. https://ajindex.com/articles/487417

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Weissman BN, Scott RD, Brick GW, Radiographic detection of metal-induced synovitisas a complication of arthroplasty of the knee. J Bone Surg Am 1991: 73-A: 1002-7.
  2. Rader CP, Lohr H, Whittmann R, ResuIts of total knee arthroplasty with a metalhacked patellar component: a 6-year follow-up study. J Arthroplastv 1996: 11: 923- 30. Yukihide M, Akio K, Hiroyoshi I, Polyethylene Wear Particles in Synovial Fluid After Total Knee Arthroplasty Clinical Orthopaedics and related research Number 410, pp. 165–72.
  3. Shinto Y, Uchida A, Yoshikawa H, et al. Inguinal lymphadenopathy due to metal release from a prosthesis: a case report. J Bone Joint Surg Br1993: 75- B: 266-9.