Journals / Damar Cerrahi Dergisi / 2002 / Cilt: 11 - Sayı: 1

Follow up sufficiency of extremity circulation in vascular surgery by pulse oximetry and ankle-brachial pressure index

Damar cerrahisinde ekstremite dolaşım yeterliliğinin pulse oksimetre ve ankle-brachial pressure index ile izlenmesi

Pages
33–41
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It is concluded that pulse oximetry and measurement of ABPI can be helpful in order to determine sufficiency of therapeutic interferences in early period for vascular surgery in an easy and a cheap way.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the purpose was to evaluate usage of pulse oximetry which is applied since 1980s' in cardiovascular surgery field for patients to be undergone vascular surgery (grafting, embolectomy) both in order to follow up circulation and to control treatment, and to compare it with anklebrachial pressure index (ABPI).
📊
Key Findings & Data:Significant changes were determined in all data.
💡
Conclusion & Impact:It is concluded that pulse oximetry and measurement of ABPI can be helpful in order to determine sufficiency of therapeutic interferences in early period for vascular surgery in an easy and a cheap way.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, the purpose was to evaluate usage of pulse oximetry which is applied since 1980s' in cardiovascular surgery field for patients to be undergone vascular surgery (grafting, embolectomy) both in order to follow up circulation and to control treatment, and to compare it with anklebrachial pressure index (ABPI). For patients data regarding saturation at preoperation, after operation and first hour of postoperation and ABPI at preoperation, postoperation and first hour of postoperation was recorded. Significant changes were determined in all data. It is concluded that pulse oximetry and measurement of ABPI can be helpful in order to determine sufficiency of therapeutic interferences in early period for vascular surgery in an easy and a cheap way.

Özet

1980'lerden beri kalp ve damar cerrahisi pratiğinde yaygın olarak kullanilan pulse oksimetrenin hem dolaşım izlenmesi, hem de tedavinin kontrolü amacıyla damar cerrahisi (greftleme, embolektomi) uygulanacak hastalarda kullanımını ve anklebrachial pressure index (ABPI) ile korele edilerek karşılaştırılmasının araştırımı amaçlanmıştır. Tüm hastaların; preop, operasyon sonrası ve postop 1. saatte satürasyonları ile preop ve postop 1. saatteki ABPI 'leri kaydedilmiştir. Bütün değerlerde anlamlı değişmeler saptanmıştır. Bu sonuçla pulse oksimetrenin ve ABPI ölçümünün damar cerrahisinde terapötik girişimlerin yeterliliğinin erken dönemde, kolay ve ucuz yoldan anlaşılabilmesinde yardımcı olarak kullanılabileceği gösterilmiştir.

🔖

Cite This Article

YETKİN, U. (2022). Follow up sufficiency of extremity circulation in vascular surgery by pulse oximetry and ankle-brachial pressure index. Damar Cerrahi Dergisi, Cilt: 11 - Sayı: 1, 33–41. https://ajindex.com/articles/486867

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (20)

  1. Severinghaus JW, Astrup P: The history of blood gas analysis: VI. The history of oximetry. J Clin Monit 2: 270-288, 1986
  2. Vegfors M, Tryggvason B., Sjöberg F: Assessment of peripheral blood flow using a pulse oximeter.J Clin Monit 6: 1-4, 1990
  3. Wukitsch MW, Tobler D, Pologe J: Pulse oximetry; an analysis of theory, technology and practice. J Clin Monit 4: 290-301, 1998
  4. Severinghaus JW, Kelleher JF: Recent developments in pulse oximetry. Anesthesiology 76: 1018-1038; 1992
  5. Stephen CR, Slater HM, Johnson AL: The oximeter: a technical aid for the anesthesiologist. Anesthesiology 12: 541-555, 1981
  6. Kagle DM, Alexander CM, Bekro RS: Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient reponse characteristics. Anesthesiology 66: 376-380, 1987
  7. Narang VPS: Utility of the pulse oximeter during cardiopulmonary resuscitation. Anesthesiology 65: 239-240; 1986
  8. Murphy GK, Segunda JA, Rockoff MA: Severe burns from a pulse oximeter. Anesthesiology 73:350-352; 1990
  9. Kelleher JF: Pulse oximeter. J Clin Monit 6: 1-4;1990
  10. Alexander CM, Teller LE, Gross JB: Principles of pulse oximetry: Theoretical practical considerations. Anesth Analg 68: 368-376, 1989
  11. Nellcor N-200 pulse oximetry note number 6. C-LOCK ECG synchronization principles of operation. Calif, Nellcor: Hayward, 1988
  12. Cecil WT, Thorpe KJ, Fibuch EE: A clinical evaluation of the accuracy of the Nellcor N-100 and the Ohmeda 3700 pulse oximeters. J Clin Monit 4: 31-36; 1988
  13. Bland JM, Altman.DG: Statistical methods for assessing agreement between two methods of clinical measurement, Lancet 1: 307-310; 1986
  14. Tremper KK, Barker SJ: Pulse oximetry. Anesthesiology 70: 98-108; 1990
  15. Yao ST, Hobbs JT, Irvine WT: Ankle systolic pressure measurements in arterial disease affecting the lower extremities. Br J Surg 56: 676-9, 1969
  16. Narang VPS: Utility of the pulse oximeter during cardiopulmonary resuscitation. Anesthesiology 65: 239-40, 1986
  17. Nickerson BG, Sakrison C, Tremper KK: Bias and precision of pulse oximeters and arterial oximeters. Chest 93: 515-17, 1988
  18. Mihm FG, Halperin BD: Noninvasive detection of profound arterial desaturations using a pulse oximetry device. Anesthesiology 62: 85-87, 1985
  19. Mok J, Pintan M, Benson L: Evaluation of noninvasive measurements of oxygenation in stable infants. Crit Care Med 14: 960-963, 1986
  20. Boxer RA, Gottesfeld I, Singh S: Non-invasive pulse oximetry in children with cyanotic congenital heart