Journals / Cumhuriyet Dental Journal / 2015 / Cilt: 18 - Sayı: 4

Investigation of thermal stress in differentmetal-ceramic restorations by mathematicalanalysis

Pages
311–317
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In metallic frameworks CrCoMo had the highestand semiprecious metal alloy had the lowest thermal stress deposition in its structures.Conclusions: Thermal stresses are not capable of breaking the metal-ceramic bond strength butshorten the life span of the prosthetics.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The aim of this study was to investigate the effect of heat changes in oralenvironment producing thermal stresses (TS) in prosthetic restorations by a mathematicalmethod.Material and Methods: Three different metals, commercial pure titanium (cpTi), preciousmetal alloy (Minigold, Bego dental, Bremen, Germany), chrome-cobalt-molybdenum (Wirobond,Bego dental, Bremen, Germany) were chosen for the frameworks.
📊
Key Findings & Data:Titankeramik, VM13, andOmega 900 ceramics (Vita, Bad Sackingen, Germany) were used in theoretical analysis.
💡
Conclusion & Impact:In metallic frameworks CrCoMo had the highestand semiprecious metal alloy had the lowest thermal stress deposition in its structures.Conclusions: Thermal stresses are not capable of breaking the metal-ceramic bond strength butshorten the life span of the prosthetics.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objectives: The aim of this study was to investigate the effect of heat changes in oralenvironment producing thermal stresses (TS) in prosthetic restorations by a mathematicalmethod.Material and Methods: Three different metals, commercial pure titanium (cpTi), preciousmetal alloy (Minigold, Bego dental, Bremen, Germany), chrome-cobalt-molybdenum (Wirobond,Bego dental, Bremen, Germany) were chosen for the frameworks. Titankeramik, VM13, andOmega 900 ceramics (Vita, Bad Sackingen, Germany) were used in theoretical analysis. Thephysical properties of the materials were obtained from manufacturers and from the literaturesreports. The calculation method was based on Boley’s equation.Results: In ceramics, the highest thermal stress was in titankeramik and the lowest was in VM13.Both commercial and theoretical samples were compared and at interface of the restoration,thermal stress accumulation was the highest in cpTi and titankeramik and the lowest was inprecious metal alloy and VM13 respectively. In metallic frameworks CrCoMo had the highestand semiprecious metal alloy had the lowest thermal stress deposition in its structures.Conclusions: Thermal stresses are not capable of breaking the metal-ceramic bond strength butshorten the life span of the prosthetics.

🔖

Cite This Article

COŞKUN, E., TUĞUT, F., BOYRAZ, T., AKİN, H. (2022). Investigation of thermal stress in differentmetal-ceramic restorations by mathematicalanalysis. Cumhuriyet Dental Journal, Cilt: 18 - Sayı: 4, 311–317. https://ajindex.com/articles/477111

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Kim M, Oh S, Kim J, Ju S, Seo D, Jun S, Ahn J, Ryu J. Wear evolution of the human enamel opposing different Y-TZP dental ceramics and other porcelains. J of Dent 2012;40:979‑988
  2. Kırmalı O. Dental ceramics used in dentistry. Cumhuriyet Dent J 2014;17(3):316-324
  3. Rosenblum MA, Schulman A. A review of all-ceramic restorations. JADA 1997;128:297-307
  4. Yamaguchi H, Ino S, Hamano N, Okada S, Teranaka T. Examination of bond strength and mechanical properties of Y-TZP zirconia ceramics with different surface modifications. Dent Mater J 2012;31:472–480
  5. Vásquez VZC, Özcan M, Kimpara ET. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading. Dent Mater 2009;25:221–231
  6. Etman MK, Woolford MJ. Threeyear clinical evalution of two ceramic crown system. A preliminary study. Prosthet Dent 2010;103:80-90
  7. Vasquez V, Özcan M, Nıshıoka R, Souza R, Mesquita A, Pavanelli C. Mechanical and Thermal Cycling Effects on the Flexural Strenght of Glass Ceramics Fused to Titanium. Dent Mater J 2008;27:7-15
  8. Shillinburg HT, Hobo S, Whitsett LD, Jacobi R, Bracett, SE. Susan E, Fundamentals of fixed prosthodontics: 3 Ed. Quintessence books, 1997:400-454
  9. IPS in line instruction for use, ivoclar vıvadent technical catalogue 2013;18
  10. Oyafuso DK, Ozcan M, Bottino MA, Itinoche MK. Influence of thermal and mechanical cycling on the flexural strength of ceramics with titanium and gold alloy frameworks. Dent Mater 2008;24:351–356
  11. Lin M, Xu F, Lu TJ, Bai BF. A review of heat transfer in human tooth- Experimental characterization and mathematical modeling. Dent Mater 2010;26:501-513
  12. Haskan H, Boyraz T, Kilicarslan MA. Investigation of thermal stresses in dental restoration by mathematical method. J Eur Ceram Soci 2007; 27:899–902
  13. Vojdani M, Shaghaghian S, Khaledi A, Adibi S. The effect of thermal and mechanical cycling on bond strength of a ceramic to nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys. Indian J Dent Res 2012;23:509-13. 14. http://www.mipis.com/Datasheets/ New_Katalog_na_Vita_VM_13.pdf. 15. http://www.mipis.com/Datasheets/ Katalog_na_Omega_900.pdf
  14. Mill LL. Framework design in ceramco-metal restorations. Dent Clin North Am 1977;21:699-716
  15. Phillips RW. Science of dental materials: 9th Ed. USA: WB Saunders Company, 1991;437-440
  16. Güngör MA, Küçük M, Dündar M, Karacaoğlu C, Artunç C. Effect of temperature and stress dis