Journals / Anadolu Kardiyoloji Dergisi / 2012 / Cilt: 12 - Sayı: 3

Atriyal septal defektlerin perkütan kapatılması sonrası maksimum P dalga süresi ve dispersiyon analizi: İki septal oklüderin karşılaştırılması

Analysis of maximum P-wave duration and dispersion after percutaneous closure of atrial septal defects: Comparison of two septal occluders

Pages
249–254
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results: Pmax and Pd were significantly increased immediate after procedure (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Amplatzer septal occluder (ASO) is the most widely used device for closure of atrial septal defect (ASD).
📊
Key Findings & Data:Between December 2005 and March 2010, 121 patients underwent percutaneous closure of secundum ASD were included in this study.
💡
Conclusion & Impact:Results: Pmax and Pd were significantly increased immediate after procedure (p
🔬Design:Research Article
📍Scope:2005 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: Amplatzer septal occluder (ASO) is the most widely used device for closure of atrial septal defect (ASD). Figulla septal occluder (FSO) is a similar device to ASO with some structural innovations. The aim of study is to assess the maximum P-wave duration (Pmax) and dispersion (Pd) in patients who underwent ASD closure with both devices, to determine the effects of structural innovations on atrial electrical inhomogeneity. Methods: The study is a retrospective cohort analysis. Between December 2005 and March 2010, 121 patients underwent percutaneous closure of secundum ASD were included in this study. FSO was used in 79 patients, ASO in 42 patients. Pmax and Pd were measured on the surface electrocardiography before and soon after procedure. For comparison of P-wave parameters initially and after procedure paired t-test was used. Correlation analysis was performed using Pearson correlation test. Results: Pmax and Pd were significantly increased immediate after procedure (p

Özet

Amaç: Amplatzer septal okluder (ASO) atriyal septal defektin (ASD) kapatılmasında yaygın kullanılan bir cihazdır. Bazı yapısal yenilikleri olan Figulla septal okluder (FSO) ASOya benzer bir cihazdır. Çalışmanın amacı, ASO ve FSO ile ASD kapatılan hastalarda maksimum P dalga süresi (Pmax) ve dispersiyonunu (Pd) ve bazı yeniliklerin atriyal elektriksel inhomojenite üzerine etkisini değerlendirmek. Yöntemler: Aralık 2005, Mart 2010 tarihleri arasında sekundum ASD`li 121 hastaya transkateter kapatma işlemi uygulandı ve 79 hastada FSO ve 42 hastada ASO kullanıldı. Pmax ve Pd işlemden önce ve hemen sonra yüzeysel elektrokardiyografi de ölçüldü. İki cihazla ilgili işlem öncesi ve sonrası sonuçların karşılaştırılmasında eşleştirilmiş t-testi kullanıldı. Korelasyon analizi Pearson korelasyon testi ile yapıldı. Bulgular: Pmax ve Pd işlemden hemen sonra önemli ölçüde arttı (p

🔖

Cite This Article

ECE, İ., TOPALOĞLU, S., BALLI, Ş., PAÇ, F. A., OFLAZ, M. B. (2022). Atriyal septal defektlerin perkütan kapatılması sonrası maksimum P dalga süresi ve dispersiyon analizi: İki septal oklüderin karşılaştırılması. Anadolu Kardiyoloji Dergisi, Cilt: 12 - Sayı: 3, 249–254. https://ajindex.com/articles/436399

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Kaya MG, Ozdoğru I, Baykan A, Doğan A, İnanc T, Doğdu O, et al. Transcatheter closure of secundum atrial septal defects using the ASO in adult patients: our first clinical experiences. Turk Kardiyol Dern Ars 2008; 36: 287-93
  2. Guray U, Guray Y, Mecit B, Yılmaz MB, Şaşmaz H, Korkmaz S. Maximum p wave duration and p wave dispersion in adult patients with secundum atrial septal defect: the impact of surgical repair. Ann Noninvasive Electrocardiol 2004; 9: 136-41
  3. Başpınar O, Sucu M, Koruk S, Kervancıoğlu M, Ustunsoy H, Deniz H, et al. P-wave dispersion between transcatheter and surgical closure of secundum-type atrial septal defect in childhood. Cardiol Young 2011; 21: 15-8
  4. Berger F, Vogel M, Alexi-Meskishvili V, Lange PE. Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. J Thorac Cardiovasc Surg 1999; 118: 674-8
  5. Oliver JM, Gallego P, Gonzalez A, Benito F, Mesa JM, Sobrino JA. Predisposing conditions for atrial fibrillation in atrial septal defect with and without operative closure. Am J Cardiol 2002; 89: 39-43
  6. Silversides CK, Siu SC, McLaughlin PR, Haberer KL, Webb GD, Benson L, et al. Symptomatic atrial arrhythmias and transcatheter closure of atrial septal defects in adult patients. Heart 2004; 90: 1194-8
  7. Alaeddini J, Feghali G, Jenkins S, Ramee S, White C, Abi-Samra F. Frequency of atrial tachyarrhythmias following transcatheter closure of patent foramen ovale. J Invasive Cardiol 2006; 18: 365-8
  8. Spies C, Khandelwal A, Timmermanns I, Schrader R. Incidence of atrial fibrillation following transcatheter closure of atrial septal defects in adults. Am J Cardiol 2008; 102: 902-6
  9. Klein M, Evans SJ, Blumberg S, Cataldo L, Bodenheimer MM. Use of P-wave-triggered, P-wave signal-averaged electrocardiogram to predict atrial fibrillation after coronary artery bypass surgery. Am Heart J 1995; 129: 895-901
  10. Steinberg JS, Zelenkofske S, Wong SC, Gelernt M, Sciacca R, Menchavez E. Value of the P-wave signal-averaged ECG for predicting atrial fibrillation after cardiac surgery. Circulation 1993; 88: 2618-22
  11. Rao PS, Langhough R, Beekman RH, Lloyd TR, Sideris EB. Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion. Am Heart J 1992; 124: 172-5
  12. Spies C, Timmermanns I, Schrader R. Transcatheter closure of secundum atrial septal defects in adults with the Amplatzer septal occluder: intermediate and long-term re