Cardiac computed tomography and radiation

Kardiyak bilgisayarlı tomografi ve radyasyon

Pages
374–378
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The clinicians should be well informed about the radiation reduction techniques and aware of the technical capabilities in their hospital.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:With the recent technological developments, computed tomography is becoming more important in the diagnosis of cardiovascular diseases.
📊
Key Findings & Data:However, potential complications of the radiation dose used during the test have led debates.
💡
Conclusion & Impact:The clinicians should be well informed about the radiation reduction techniques and aware of the technical capabilities in their hospital.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

With the recent technological developments, computed tomography is becoming more important in the diagnosis of cardiovascular diseases. However, potential complications of the radiation dose used during the test have led debates. In the current situation, the data about undesir- able effects of radiation dose used in cardiac computed tomography is not clear. In this paper, we reviewed the data about computed tomogra- phy and the risk of radiation. In order to reduce the risk of radiation due to computed tomography, the test should be performed with proper indication and in suitable patients. Besides, recently developed radiation dose reduction technologies and patient specific protocols have sig- nificantly reduced the radiation exposure. The clinicians should be well informed about the radiation reduction techniques and aware of the technical capabilities in their hospital.

Özet

Son yıllardaki teknik gelişmeler nedeniyle kardiyovasküler hastalıkların tanısında bilgisayarlı tomografinin yeri gün geçtikçe artmaktadır. Ancak bu işlem sırasında kullanılan radyasyon dozu, buna bağlı oluşabilecek potansiyel sonuçlar konusunda tartışma yaratmaktadır. Elimizde henüz bilgisayarlı tomografide kullanılan radyasyon dozunun yol açabileceği istenmeyen etkiler konusunda net veriler bulunmamaktadır. Bu derlemede bilgisayarlı tomografi ve radyasyon riski ile ilgili literatürdeki veriler gözden geçirilmiştir. Bilgisayarlı tomografide kullanılan radyasyon dozunu azaltmak için alınabilecek önlemlerin başında testin doğru endikasyonla, uygun hastada yapılması gelmektedir. Bunun yanında son yıllarda geliştirilen radyasyon azaltıcı teknolojiler ve kişiye özgü çekim teknikleri sayesinde kullanılan radyasyon dozu belirgin ölçüde azaltılabilmektedir. Klinisyenlerin radyasyon riskinin azaltılması açısından kullanılması gereken teknikler konusunda bilgi sahibi olmaları ve çalıştıkları merkezdeki teknik olanakların farkında olmaları önem taşımaktadır.

🔖

Cite This Article

SEZENÖZ, B., ŞAHİNARSLAN, A. (2022). Cardiac computed tomography and radiation. Anadolu Kardiyoloji Dergisi, Cilt: 13 - Sayı: 4, 374–378. https://ajindex.com/articles/436279

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery dise- ase: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 2008
  2. [CrossRef] 2. Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, mul- tivendor study. J Am Coll Cardiol 2008
  3. [CrossRef] 3. Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 2008
  4. [CrossRef] 4. Desai MY. Cardiac CT beyond coronary angiography: current and emerging non-coronary cardiac applications. Heart 2011
  5. [CrossRef] 5. Smith-Bindman R, Lipson J, Marcus R, Kim KP Mahesh M, Gould R, et al. Radiation dose associated with common computed tomog- raphy examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 2009
  6. [CrossRef] 6. Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 2007
  7. [CrossRef] 7. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med 2007
  8. [CrossRef] 8. Roobottom CA, Mitchell G, Morgan-Hughes G. Radiation reduction strategies in cardiac computed tomographic angiography. Clin Radiol 2010
  9. [CrossRef] 9. Suzuki K, Yamashita S. Low-dose radiation exposure and carcino- genesis. Jpn J Clin Oncol 2012
  10. [CrossRef] 10. Hallibutton SS, Schoenhagen P Cardiovascular imaging with com- puted tomography: responsible steps to balancing diagnostic yield and radiation. JACC Cardiovasc Imaging 2010
  11. [CrossRef] 11. Shapiro BP Young PM, Kantor B, Choe YH, McCollough CH, Gerber TC. Radiation dose reduction in CT coronary angiography. Curr Cardiol Rep 2010
  12. [CrossRef] 12. Coles DR, Smail MA, Negus IS, Wilde P Oberhoff M, Karsch KR, et al. Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am