Journals / Anadolu Kardiyoloji Dergisi / 2014 / Cilt: 14 - Sayı: 6

Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system

Pages
556–557
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
🔖

Cite This Article

GÜLER, E., KARACA, O., KIZILIRMAK, F., BABÜR, G. G., KILIÇASLAN, F. (2022). Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system. Anadolu Kardiyoloji Dergisi, Cilt: 14 - Sayı: 6, 556–557. https://ajindex.com/articles/436110

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Poutiainen AM, Koistinen MJ, Airaksinen KE, Hartikainen EK, Kettunen RV, Karjalainen JE, et al. Prevalence and natural course of ectopic atrial tachycardia. Eur Heart J 1999; 20: 694-700. [CrossRef] 2. Pandozi C, Galeazzi M, Lavalle C, Ficili S, Russo M, Santini M. Navx- guided Cryoablation of Atrial Tachycardia Inside the Left Atrial Appendage. Indian Pacing Electrophysiol J 2011; 10: 556-61. 3. Roberts-Thomson KC, Kistler PM, Kalman JM, Atrial tachycardia: mecha- nisms, diagnosis, and management. Curr Probl Cardiol 2005; 30: 529-73. [CrossRef] 4. Raatikainen MJ, Huikuri HV. Successful catheter ablation of focal atrial tachycardia from the non-coronary aortic cusp. Europace 2007; 9: 216-9. [CrossRef] 5. Casella M, Pelargonio G, Dello Russo A, Riva S, Bartoletti S, Santangeli P, et al "Near-zero" fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literature. J Interv Card Electrophysiol 2011; 31: 109-18. [CrossRef] 6. Jamil-Copley S, Linton N, Koa-Wing M, Kojodjojo P, Lim PB, Malcolme- Lawes L, et al. Application of ripple mapping with an electroanatomic mapping system for diagnosis of atrial tachycardias. J Cardiovasc Electrophysiol 2013; 24: 1361-9. [CrossRef] 7. Duru F. CARTO three-dimensional non-fluoroscopic electroanatomic mapping for catheter ablation of arrhythmias: a useful tool or an expen- sive toy for the electrophysiologist? Anadolu Kardiyol Derg 2002; 2: 330-7. 8. Casella M, Dello Russo A, Pelargonio G, Bongiorni MG, Del Greco M, Piacenti M, et al. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients. Cardiol Young 2012; 22: 539-46. [CrossRef] 9. Banchs JE, Patel P, Naccarelli GV, Gonzalez MD. Intracardiac echocar- diography in complex cardiac catheter ablation procedures. J Interv Card Electrophysiol 2010; 28: 167-84. [CrossRef] 10. Ouyang F, Ma J, Ho SY, Bänsch D, Schmidt B, Ernst S, et al. Focal atrial tachycardia originating from the non-coronary aortic sinus: electrophysi- ological characteristics and catheter ablation. J Am Coll Cardiol 2006; 48: 122-31. [CrossRef]