Journals / Akdeniz Tıp Dergisi / 2016 / Cilt: 2 - Sayı: 2

Report of a Humeral Non-Union that Occurred After Inflatable Nail Fixation. A Systematic Review of the Literature and Case Presentation

Şişebilen İntramedüller Çivi ile Tedavi Sonrası Oluşan Bir Kaynamama Olgusu. Literatürün Sistematik Gözden Geçirilmesi ve Olgu Sunumu

Pages
55–62
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The aim of this study was to present a didactic case of humeral non-union that occurred after inflatable nail fixation and to share the implications of this case with a systematic review of the literature regarding inflatable intramedullary choices for humeral diaphysis fracture

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Dynamic compression plate with screw ostesynthesis is still the gold standard for the surgical approach to humeral diaphysis fractures.
📊
Key Findings & Data:However, inflatable intramedullary nails are now preferred by surgeons as they offer the technical advantage of not using a distal locking bolt.
💡
Conclusion & Impact:The aim of this study was to present a didactic case of humeral non-union that occurred after inflatable nail fixation and to share the implications of this case with a systematic review of the literature regarding inflatable intramedullary choices for humeral diaphysis fracture
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Humerus diafiz kırığı · Şişebilen intramedüller çivi · Kaynamama

Abstract

Dynamic compression plate with screw ostesynthesis is still the gold standard for the surgical approach to humeral diaphysis fractures. However, inflatable intramedullary nails are now preferred by surgeons as they offer the technical advantage of not using a distal locking bolt. The aim of this study was to present a didactic case of humeral non-union that occurred after inflatable nail fixation and to share the implications of this case with a systematic review of the literature regarding inflatable intramedullary choices for humeral diaphysis fracture

Özet

Humerus diafiz kırıklarının cerrahi tedavisinde halen altın standart plaklı osteosentezdir, ancak intramedüller şişebilen çivilemenin geliştirilmesi skopi kontrolündeki anterotasyon distal vida konulmasının teknik zorluğunu ortadan kaldırabildiği için cerrahlar tarafından tercih edilir olmuştur. Bu makalede humeral diafiz kırığı nedeni ile şişebilen intramedüller çivi ile opere edilmiş bir didaktik olgunun sunulması ve literatürün gözden geçirilip elde edilen bulguları ve bu olgunun bize verdiği klinik dersi okuyucuyla paylaşmayı hedefledik

🔖

Cite This Article

SAĞTAŞ, E., DELİAĞA, P., DEMİRCİ, E., SAYLİK, M., AYDIN, A. T., GÖKKUŞ, K. (2022). Report of a Humeral Non-Union that Occurred After Inflatable Nail Fixation. A Systematic Review of the Literature and Case Presentation. Akdeniz Tıp Dergisi, Cilt: 2 - Sayı: 2, 55–62. https://ajindex.com/articles/434521

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Böhler L. Conservative treatment of fresh closed fractures of the shaft of the humerus. J Trauma 1965; 5: 464-68. Charnley J. The closed Treatment of Common Fractures. London: Churchill Livingstone 1974.
  2. Jupiter JB, Van Deck M. Ununited humeral diaphyses. J Shoulder Elbow Surg 1998; 7:644-53.
  3. Sarmiento A, Waddell JP, Latta LL. Diaphyseal humeral fractures: Treatment options. J Bone Joint Surg 2001; 83- A: 1566-79.
  4. Farragos AF, Schemitsch EH, McKee MD. Complications of intramedullary nailing for fractures of the humeral shaft: A review. J Orthop Trauma 1999;13(4):258-67. Browner: Skeletal Trauma: Basic Science, Management, and Reconstruction. 3rd ed. Fractures of Humerus management. Saunders Elsevier 2003.
  5. Lorich DG, Geller DS,Yacoubian SV, Leo AJ, Helfet DL. Intramedullary fixation of humeral shaft fractures using an inflatable nail. Orthopedics 2003 26(10):1011-4.
  6. Pittlik N, Hartwig T, Berger S, van der Horst W. First experiences with the Fixion nail. A new way of intramedullary nailing system. Eur J Trauma 2002; Suppl 1: 117. Tauber M, Shasha N. Fixion IM nail-an innovative inflatable self-locking intramedullary nailing system for fractures of the long bones. AAOS. San Francisco, USA; February 2001.
  7. Mallick E, Hazarika S,Assad S, Scott M.The fixion nailing system for stabilising diaphyseal fractures of the humerus: A two-year clinical experience. Acta Orthop Belg 2008; 74(3): 308-16.
  8. Smith WR, Ziran B, Agudelo JF, Morgan SJ, Lahti Z, Vanderheiden T, Williams A. Expandable intramedullary nailing for tibial and femoral fractures: A preliminary analysis of perioperative complications. J Orthop Trauma 2006; 20(5): 310-4.
  9. Smith MG, Canty SJ, Khan SA. Fixion-an inflatable or deflatable nail ? Injury 2004; 35(3):329-31.
  10. Ozturk H, Unsaldi T, Oztemur Z, Bulut O, Korkmaz M, Demirel H. Extreme complications of Fixion nail in treatment of long bone fractures. Arch Orthop Trauma Surg 2008; 128(3):301-6.
  11. Dağlar B, Delialioğlu OM, Taşbaş BA, Bayrakçi K, Ağar M, Günel U. Comparison of plate-screw fixation and intramedullary fixation with inflatable nails in the treatment of acute humeral shaft fractures. Acta Orthop Traumatol Turc 2007; 41(1):7-14.
  12. Franck WM, Olivieri M, Jannasch O, Hennig FF. Expandable nail system for osteoporotic humeral shaft fractures: preliminary results. J Trauma. 2003; 54(6): 1152-8.
  13. Panidis G, Sayegh F, Beletsiotis A, et al. The use of an innovativeinflatable self-locking intramedullary nail in treating and stabilizing long bone fractures. Tech