Journals / Laparoscopic Endoscopic Surgical Science / 2020 / Cilt: 27 - Sayı: 4

Bladeless optical trocar insertion technique for initial access in morbidly obese patients: Technique and results

Pages
193–198
Publication Date
2022-09-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Initial access to the abdomen by a bladeless optical trocar without producing pneumoperitoneum is a practical, fast, safe, and effective method in morbidly obese patients

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Introduction: The initial access into the abdomen during laparoscopic surgery can become difficult and complex, especially in morbidly obese patients.
📊
Key Findings & Data:Materials and Methods: The study included 170 patients who underwent surgery to treat morbid obesity from January 2015 to December 2017.
💡
Conclusion & Impact:Conclusion: Initial access to the abdomen by a bladeless optical trocar without producing pneumoperitoneum is a practical, fast, safe, and effective method in morbidly obese patients
🔬Design:Research Article
📍Scope:2015 Verileri
⚙️Variables:Domain Parameters

Abstract

Introduction: The initial access into the abdomen during laparoscopic surgery can become difficult and complex, especially in morbidly obese patients. No ideal technique to solve this issue has been elucidated. In this study, we aimed to evaluate the safety and feasibility of using a bladeless optical trocar for abdominal entry without producing pneumoperitoneum in morbidly obese patients. Materials and Methods: The study included 170 patients who underwent surgery to treat morbid obesity from January 2015 to December 2017. Demographic data, data about the initial access to the abdomen, and the complications were recorded. Results: All surgical procedures were performed by the same team of two surgeons. The mean body mass index (BMI) of the patients was 45.8±6.0 kg/m². The Veress needle access failed in the first five patients. The initial access was successfully achieved in all patients, including the first five patients, by using a bladeless optical trocar without producing pneumoperitoneum. After the skin incision, insufflation and trocar insertion were completed in a mean period of 58±35.3 (range; 23–272) seconds. Omental injury due to trocar insertion occurred in two patients. No other complications developed. Fascial defect closures were not performed for any patient. The mean operating times for sleeve gastrectomy and the Roux-en-Y gastric bypass were 76±19 (range: 45–135) and 203±61.4 (range: 100–345) minutes, respectively. During the follow-up period of 24 months, no patient developed trocar site hernia. Conclusion: Initial access to the abdomen by a bladeless optical trocar without producing pneumoperitoneum is a practical, fast, safe, and effective method in morbidly obese patients

🔖

Cite This Article

Yüksel, A., Coşkun, M. (2022). Bladeless optical trocar insertion technique for initial access in morbidly obese patients: Technique and results. Laparoscopic Endoscopic Surgical Science, Cilt: 27 - Sayı: 4, 193–198. https://ajindex.com/articles/423562

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Chapron CM, Pierre F, Lacroix S, Querleu D, Lansac J, Dubuisson JB. Major vascular injuries during gynecologic laparoscopy. J Am Coll Surg 1997;185:461−5. [CrossRef] 2. Ambardar S, Cabot J, Cekic V, Baxter K, Arnell TD, Forde KA, et al. Abdominal wall dimensions and umbilical position vary widely with BMI and should be taken into account when choosing port locations. Surg Endosc 2009;23:1995−2000. 3. Ahmad G, Baker J, Finnerty J, Phillips K, Watson A. Laparoscopic entry techniques. Cochrane Database Syst Rev 2019;18;1:CD006583. [CrossRef] 4. Curet MJ. Special problems in laparoscopic surgery. Previous abdominal surgery, obesity, and pregnancy. Surg Clin North Am 2000;80:1093−110. [CrossRef] 5. Ahmad G, O’Flynn H, Duffy JM, Phillips K, Watson A. Laparoscopic entry techniques. Cochrane Database Syst Rev 2012 15;CD006583. [CrossRef] 6. Marcovich R, Del Terzo MA, Wolf JS Jr. Comparison of transperitoneal laparoscopic access techniques: Optiview visualizing trocar and Veress needle. J Endourol 2000;14:175−9. [CrossRef] 7. Teoh B, Sen R, Abbott J. An evaluation of four tests used to ascertain Veres needle placement at closed laparoscopy. J Minim Invasive Gynecol 2005;12:153−8. [CrossRef] 8. Poindexter AN, Ritter M, Fahim A, Humphrey H. Trocar introduction performed during laparoscopy of the obese patient. Surg Gynecol Obstet 1987;165:57−9. 9. Vakili C, Knight R. A technique for needle insufflation in obese patients. Surg Laparosc Endosc 1993;3:489−91. 10. Hashizume M, Sugimachi K. Needle and trocar injury during laparoscopic surgery in Japan. Surg Endosc 1997;11:1198−201. [CrossRef] 11. Mayol J, Garcia-Aguilar J, Ortiz-Oshiro E, De-Diego Carmona JA, Fernandez-Represa JA. Risks of the minimal access approach for laparoscopic surgery: multivariate analysis of morbidity related to umbilical trocar insertion. World J Surg 1997;21:529−33. [CrossRef] 12. Larobina M, Nottle P. Complete evidence regarding major vascular injuries during laparoscopic access. Surg Laparosc Endosc Percutan Tech 2005;15:119−23. [CrossRef] 13. Hasson HM. Open laparoscopy as a method of access in laparoscopic surgery. Gynaecological Endoscopy 1999;8:353−62. [CrossRef] 14. Altun H, Banli O, Karakoyun R, Boyuk A, Okuducu M, Onur E, et al. Direct trocar insertion technique for initial access in morbid obesity surgery: technique and results. Surg Laparosc Endosc Percutan Tech 2010;20:228-30. [CrossRef] 15. Ertugrul I, Kayaalp C, Yagci MA, Sumer F, Karagul S, Tolan K. Comparison of Direct Trocar