Journals / Turkish Journal of Surgery / 2018 / Cilt: 34 - Sayı: 1

First experience with a new technique: Portable gamma camera usage for sentinel lymph node identification in a patient with breast cancer

Pages
57–59
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this case report, the value of additional portablegamma camera imaging was analyzed.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The newest development in sentinel lymph node imaging is portable gamma probe imaging.
📊
Key Findings & Data:In this case report,results of all SLN detection methods were analyzed.
💡
Conclusion & Impact:In this case report, the value of additional portablegamma camera imaging was analyzed.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

The newest development in sentinel lymph node imaging is portable gamma probe imaging. In this case report,results of all SLN detection methods were analyzed. The patient was imaged using a large field-of-view gammacamera with additional blue dye administration and intraoperative localization of sentinel lymph node using bothgamma probe and portable gamma camera was performed. In this case report, the value of additional portablegamma camera imaging was analyzed.

🔖

Cite This Article

KOÇ, Z. P., KARA, P. P. Ö., BERKEŞOĞLU, M., AKÇA, T. (2018). First experience with a new technique: Portable gamma camera usage for sentinel lymph node identification in a patient with breast cancer. Turkish Journal of Surgery, Cilt: 34 - Sayı: 1, 57–59. https://ajindex.com/articles/390557

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Bao J, Donovan C, Chung A, Giuliano AE. The staging value of sentinel lymph node biopsy for breast cancer: translating pathologic findings to clinical practice. Chin Clin Oncol 2016; 5: 36. [CrossRef] Lee JH. Radionuclide methods for breast cancer staging. Semin Nucl Med 2013; 43: 294-298. [CrossRef] Arslan G, Altintoprak KM, Yirgin IK, Atasoy MM, Celik L. Diagnostic accuracy of metastatic axillary lymph nodes in breast MRI. Springerplus 2016; 5: 735. [CrossRef] Nowikiewicz T, Kurylcio A, Polkowski W, Zegarski W. Imaging methods for the local lymphatic system of the axilla in early breast cancer in patients qualified forsentinel lymph node biopsy. Prz Menopauzalny 2016; 15: 52-55. [CrossRef] Goñi Gironés E, Vicente García F, Serra Arbeloa P, Estébanez Estébanez C, Calvo Benito A, Rodrigo Rincón I, et al. Evaluation of the efficacy of sentinel node detection in breast cancer: chronological course and influence of the incorporation of an intra-operative portable gamma camera. Rev Esp Med Nucl Imagen Mol 2013; 32: 343-349. [CrossRef] Chondrogiannis S, Ferretti A, Facci E, Marzola MC, Rampin L, Tadayyon S, et al. Intraoperative hand-held imaging γ-camera for sentinel node detection in patients with breastcancer: feasibility evaluation and preliminary experience on 16 patients. ClinNucl Med 2013; 38: e132-136. [CrossRef] Rasilla JM, Arboniés JC, Bolton RD, Pereyra LI, Andía GS, Soriano AP, et al. SPECT-CT in sentinel node detection in patients with melanoma. Rev Esp Med Nucl 2009; 28: 229-234.
  2. Silverio AM, McRae MC, Ariyan S, Narayan D. Management of the difficult sentinel lymph node in patients with primary cutaneous melanoma. Ann PlastSurg 2009; 62: 564-569. [CrossRef] Vidal-Sicart S, Paredes P, Zanón G, Pahisa J, Martinez-Román S, Caparrós X, et al. Added value of intraoperative real-time imaging in searches for difficult-to-locate sentinel nodes. J Nucl Med 2010; 51: 1219-1225. [CrossRef] Soluri A, Massari R, Trotta C, Tofani A, Di Santo G, Di Pietro B, et al. Small field of view, high-resolution, portable γ-camera for axillary sentinel node detection. NuclInstrum Methods Phys Res A 2006; 569: 273-276. [CrossRef] Vermeeren L, Valdés Olmos RA, Klop WM, Balm AJ, van den Brekel MW. A portable gamma-camera for intraoperative detection of sentinel nodes in the head and neck region. J Nucl Med 2010; 51: 700-703. [CrossRef] Vidal-Sicart S, Vermeeren L, Solà O, Paredes P, Valdés-Olmos RA. The use of a portable gamma camera for preoperative lymphatic mapping: a comp