Journals / The Journal of Breast Health / 2017 / Cilt: 13 - Sayı: 2

Ultrasound Guided Therapeutic Excisional Vacuum Assisted Biopsy in Breast Fibroadenomas

Pages
74–76
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A multidisciplinary clinical environment is necessary for each step of the treatment.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: fte aim of this study was to evaluate the performance of ultrasound (US) guided Vacuum Assisted Biopsy (VAB) in the therapeutic excision of breast fibroadenomas.Materials and Methods: Patients who underwent excisional US guided VAB of their fibroadenomas between December 1999-May 2001 were retrospectively evaluated.
📊
Key Findings & Data:Seventy-eight patients with BI-RADS category 3 and 4a lesions (one lesion per patient) with a maximum diameter smaller than 3 cm were enrolled in the study.
💡
Conclusion & Impact:A multidisciplinary clinical environment is necessary for each step of the treatment.
🔬Design:Research Article
📍Scope:2001 Verileri
⚙️Variables:Domain Parameters

Özet

Objective: fte aim of this study was to evaluate the performance of ultrasound (US) guided Vacuum Assisted Biopsy (VAB) in the therapeutic excision of breast fibroadenomas.Materials and Methods: Patients who underwent excisional US guided VAB of their fibroadenomas between December 1999-May 2001 were retrospectively evaluated. Seventy-eight patients with BI-RADS category 3 and 4a lesions (one lesion per patient) with a maximum diameter smaller than 3 cm were enrolled in the study. Fifty-one of those were diagnosed with fibroadenoma. Biopsies were performed with a 11G needle using the Mammotome (Johnson & Johnson, New Jersey, USA) vacuum biopsy device. Patients were followed up with US for three years. Follow-ups were done semiannually in the first year and annually afterwards.Results: Ten patients (19%) were found to have residual lesions in the first week after the biopsy. Additional eight patients (15%) were found to have residual-recurrent lesions in their annual follow up. However, none of these eight lesions demonstrated growth during the three year follow-up. fte initial size of the FA was not found to be significantly different between the lesions which were completely excised with no residue or recurrence and those which were not (p>0.05).Conclusion: fte VAB method for the therapeutic excision of small FAs or other benign lesions is practical and easily tolerated by patients. Lesions smaller than 3 cm should be preferred for VAB. A multidisciplinary clinical environment is necessary for each step of the treatment.

🔖

Cite This Article

BUĞDAYCI, O., KAYA, H. (2017). Ultrasound Guided Therapeutic Excisional Vacuum Assisted Biopsy in Breast Fibroadenomas. The Journal of Breast Health, Cilt: 13 - Sayı: 2, 74–76. https://ajindex.com/articles/362635

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. NHS Breast Screening Programme (NHSBSP): An Audit of Screen Detected Breast Cancers for the Year of Screening April 2008 to March 2009. Available from: http://webarchive.nationalarchives. gov. uk/20150506150512/http://www.cancerscreening.nhs.uk/breastscreen/ publications/baso2008-2009.pdf (Accessed on 11.03.2017)
  2. Greenberg R, Skornick Y, Kaplan O. Management of breast fibroadeno- mas. J Gen Intern Med 1998; 13: 640-645. (PMID:9754521) [CrossRef] Park HL, Kim LS. fte current role of vacuum assisted breast biopsy sys- tem in breast disease. J Breast Cancer 2011; 14: 1-7. (PMID: 21847387) [CrossRef] O’Flynn EA, Wilson AR, Michell MJ. Image-guided breast biopsy: state-of-the-art. Clin Radiol 2010; 65: 259-270. (PMID: 20338392) [CrossRef ] Adepoju L, Qu W, Kazan V, Nazzal M, Williams M, Sferra J. fte evalu- ation of national time trends, quality of care, and factors affecting the use of minimally invasive breast biopsy and open biopsy for diagnosis of breast lesions. Am J Surg 2014; 208: 382-390. [CrossRef] Kim MJ, Park BW, Kim SI, Youk JH, Kwak JY, Moon HJ, Kim EK. Long-term follow-up results for ultrasound-guided vacuum-assisted removal of benign palpable breast mass. Am J Surg 2010; 199: 1-7. (PMID:19409529) [CrossRef] Wang ZL, Li JL, Su L, Zhang YF, Tang J. An evaluation of a 10-gauge vacuum-assisted system for ultrasound-guided excision of clinically be- nign breast lesions. fte Breast 2009; 18: 192-196. [CrossRef] Hahn M, Krainick-Strobel U, Toellner T, Gissler J, Kluge S, Krapfl E, Peisker U, Duda V, Degenhardt F, Sinn HP, Wallwiener D, Gruber IV; Minimally Invasive Breast Intervention Study Group (AG MiMi) of the German Society of Senology (DGS); Study Group for Breast Ultrasonography of the German Society for Ultrasound in Medicine (DEGUM). Interdisciplinary consensus recommendations for the use of vacuum-assisted breast biopsy under sonographic guidance: first up- date 2012. Ultraschall Med 2012; 33: 366-371. (PMID:22723042) [CrossRef ] fturley P, Evans A, Hamilton L, James J, Wilson R. Patient satisfaction and efficacy of vacuum-assisted excision biopsy of fibroadenomas. Clin Radiol 2009; 64: 381-385. (PMID:19264182) [CrossRef] Krainick‐Strobel U, Huber B, Majer I, Bergmann A, Gall C, Gruber I, Hoffmann J, Paepke S, Peisker U, Walz-Mattmüller R, Siegmann K, Wallwiener D, Hahn M. Complete extirpation of benign breast lesions with an ultrasound‐guided vacuum biopsy system. Ultrasound Obstet Gynecol 2007; 29: 342-346. (PMID: 17167817) [CrossRef] Johnson