Journals / Turkish Journal of Medical Sciences / 2017 / Cilt: 47 - Sayı: 6

Concordance of immunohistochemistry between core needle biopsy and surgical resection of breast cancer

Pages
1791–1796
Publication Date
2017-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results: Concordance rates were 93.3% for ER, 89.4% for PR, 90.1% for HER-2, and 80.9% for Ki-67.Conclusion: CNB is accurate for the evaluation of the surrogate molecular profile of invasive breast cancer despite the heterogeneity of tumors.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: The purpose of this study was to evaluate the concordance of immunohistochemical (IHC) parameters of breast lesions between the core needle biopsy (CNB) and the surgical resection specimen.
📊
Key Findings & Data:ER, PR, HER-2, and Ki-67 parameters were compared for each patient.
💡
Conclusion & Impact:Results: Concordance rates were 93.3% for ER, 89.4% for PR, 90.1% for HER-2, and 80.9% for Ki-67.Conclusion: CNB is accurate for the evaluation of the surrogate molecular profile of invasive breast cancer despite the heterogeneity of tumors.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Breast cancer · image-guided biopsy · immunohistochemistry

Abstract

Background/aim: The purpose of this study was to evaluate the concordance of immunohistochemical (IHC) parameters of breast lesions between the core needle biopsy (CNB) and the surgical resection specimen. Materials and methods: CNB and resection specimens of female patients were retrospectively analyzed. ER, PR, HER-2, and Ki-67 parameters were compared for each patient. A total of 284 cases were assessed. Forty-one and 48 cases were excluded from the HER-2 and Ki-67 examinations, respectively, because the CNBs did not allow for IHC. Results: Concordance rates were 93.3% for ER, 89.4% for PR, 90.1% for HER-2, and 80.9% for Ki-67.Conclusion: CNB is accurate for the evaluation of the surrogate molecular profile of invasive breast cancer despite the heterogeneity of tumors.

🔖

Cite This Article

KOMBAK, F. E., ŞAHİN, H., MOLLAMEMİŞOĞLU, H., ÖNEM, İ., KAYA, H., BUĞDAYCI, O., ARIBAL, M. E. (2017). Concordance of immunohistochemistry between core needle biopsy and surgical resection of breast cancer. Turkish Journal of Medical Sciences, Cilt: 47 - Sayı: 6, 1791–1796. https://ajindex.com/articles/113455

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...