⚡ TL;DR(Too Long; Didn't Read)

More importantly is that these yield line mechanisms can be directly implemented to AISC 358 and Turkish Building Earthquake Code 2018 (TBEC-2018).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Extended end-plated connections are preferred in moment resisting frames due to their advantages such as no required in-situ welding, accurate fabrication and economic feasibility compared to flange welded moment connections.
📊
Key Findings & Data:The thickness of end-plate can be computed using yield line mechanisms.
💡
Conclusion & Impact:More importantly is that these yield line mechanisms can be directly implemented to AISC 358 and Turkish Building Earthquake Code 2018 (TBEC-2018).
🔬Design:Research Article
📍Scope:2018 Verileri
⚙️Variables:Domain Parameters

Özet

Extended end-plated connections are preferred in moment resisting frames due to their advantages such as no required in-situ welding, accurate fabrication and economic feasibility compared to flange welded moment connections. The capacity of the extended end-plated connections depends on bolt configurations, end-plate thickness, bolt diameter and their material properties excluding column part. The thickness of end-plate can be computed using yield line mechanisms. Different yield line patterns are available in the literature and some of these are adopted in seismic codes to estimate the thickness of end-plate. In this study, the accuracy of different yield line patterns is compared using collected experimental data and numerical analysis. A parametric numerical analysis was conducted utilizing the finite element tool, ABAQUS. The results of experimental data and parametric study were evaluated for both unstiffened and stiffened four bolted extended end-plated connections. The results revealed that the capacity of the end-plate connections significantly depends on the yield line mechanism. Therefore, selecting an accurate yield line mechanism is essential in order not to overestimate the thickness of the end-plate. More importantly is that these yield line mechanisms can be directly implemented to AISC 358 and Turkish Building Earthquake Code 2018 (TBEC-2018).

🔖

Cite This Article

ÖZKILIÇ, Y. O. (2021). A comparative study on yield line mechanisms for four bolted extended end-plated connection. Challenge Journal of Structural Mechanics, Cilt: 7 - Sayı: 2, 93–106. https://ajindex.com/articles/351789

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Abel MSM, Murray TM (1994). Analytical and Experimental Investigation of the Extended Unstiffened Moment End-plate Connection with Four Bolts at the Beam Tension Flange. Jr. Department of Civil Engineering, Structures and Materials Research Laboratory, Virginia Polytechnic Institute and State University. Adegoke IO (2009). Ductility of Thin Extended Endplate Connections. Ph.D thesis, University of the Witwatersrand, Johannesburg. Adey BT, Grondin GY, Cheng JJR (1997). Behaviour of extended end plate moment connections under cyclic loading. Structural Engineering Report No. 216, Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alta. AISC 341–16 (2016). Seismic Provisions for Structural Steel Buildings. American Institute of Steel Construction, Chicago, IL. AISC 358–16 (2016). Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications. American Institute of Steel Construction, Chicago, IL. Akgönen Aİ, Güneş B (2017). Alın levhalı moment birleşimlerin sonlu elemanlar ile analizi. Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi, 17(2), 646-657. (in Turkish) Aleksander K, Damian K (2019). Experimental tests of steel unstiffened double side joints with flush and extended end plate. Archives of Civil Engineering, 65(4), 127-154.
  2. Arul Jayachandran S, Marimuthu V, Prabha P, Seetharaman S, Pandian N (2009). Investigations on the behaviour of semi-rigid endplate connections. Advanced Steel Construction, 5(4), 432-451.
  3. Borgsmiller JT (1995). Simplified Method for Design of Moment EndPlate Connections, M.Sc Thesis, Virginia Polytechnic Institute and State University, Blacksburg, Virginia. Borgsmiller J, Sumner E, Murray T (1995). Tests of Extended Moment End-Plate Connections Having Large Inner Pitch Distances. Research Report CE/VPI-ST-95/01 Department of Civil Engineering. Virginia Polytechnic Institute and State University. Blacksburg VA. Bu Y, Wang Y, Zhao Y (2019). Study of stainless steel bolted extended end-plate joints under seismic loading. Thin-Walled Structures, 144, 106255. Bursi OS, Jaspart JP (1997). Calibration of a finite element model for isolated bolted end-plate steel connections. Journal of Constructional Steel Research, 44(3), 225-262.
  4. Chasten CP, Lu LW, Driscoll GC (1992). Prying and shear in end-plate connection design. Journal of Structural Engineering, ASCE, 118(5), 1295-1311.
  5. Coelho AMG, Bijlaard FS, da Silva LS (2004). Experimental assessment of the du