Journals / Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi / 2007 / Cilt: 22 - Sayı: 2

Comparing of hydrometer analysis done with two different calgon (sodium hexametaphosphate)

Farklı iki kalgon (sodyum hegzametafosfat)'la yapılan hidrometre analizlerinin karşılaştırılması

Pages
285–289
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It were observed water tempure and foam increase during mixing lime solition calgon, water, and soil sample by mixer.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, it was used two different calgon in hydrometer analysis (particle size analysis) of a fine particle soil and results were compared.
📊
Key Findings & Data:According to results, it was determined that values which obtained at the end of hydrometer analysis done by lime solition was high.
💡
Conclusion & Impact:It were observed water tempure and foam increase during mixing lime solition calgon, water, and soil sample by mixer.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, it was used two different calgon in hydrometer analysis (particle size analysis) of a fine particle soil and results were compared. According to results, it was determined that values which obtained at the end of hydrometer analysis done by lime solition was high. Cause of this, density of lime solition calgon is high. It were observed water tempure and foam increase during mixing lime solition calgon, water, and soil sample by mixer.

Özet

Bu çalışmada; ince taneli bir zeminin hidrometre analizlerinde (tane boyu analizleri) iki farklı kalgon kullanılmış ve sonuçlar karşılaştırılmıştır. Elde edilen sonuçlardan kireç çözücü kalgon’la yapılan hidrometre analizi sonucunda elde edilen değerlerin yüksek çıktığı belirlenmiştir. Bunun nedeninin kireç çözücü kalgonun yoğunluğunun yüksek olmasıdır. Kireç çözücü kalgon, su ve zemin numunesi karışımını mikserle karıştırma süresince suyun sıcaklığının ve köpüklenme olayının arttığı da gözlenmiştir.

🔖

Cite This Article

GÖKOĞLU, A., ÖZVAN, A. (2007). Comparing of hydrometer analysis done with two different calgon (sodium hexametaphosphate). Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi, Cilt: 22 - Sayı: 2, 285–289. https://ajindex.com/articles/350836

References (8)

  1. Holtz,R. and Kovacs,W.D., “Geoteknik Mühendisliğine Giriş”, (Çeviren: Kayabalı,K.), Gazi Kitabevi, 723s., Ankara, 2002
  2. ASTM D 854-02, “Standard test method for specific gravity of soil solids by water pycnometer”, In: Annual Book of ASTM Standards, Volume 04.08, 93-99, West Conshohocken, PA., 2003
  3. ASTM D 2216-98, “Standard test method for laboratory determination of water (moisture) content of soil and rock by mass”, In: Annual Book of ASTM Standards, Volume 04.08, 219-223, West Conshohocken, PA., 2003
  4. ASTM D 422-63, “Standard test method for particle-size analysis of soils”, In: Annual Book of ASTM Standards, Volume 04.08, 10-17, West Conshohocken, PA., 2003
  5. ASTM D 4318-02, “Standard test method for liquid limit, plastic limit, and plasticity index of soils”, In: Annual Book of ASTM Standards, Volume 04.08, 582-595, West Conshohocken, PA., 2003
  6. ASTM D 2487-00, “Standard practise for classification of soils for engineering purposes (unified soil classification system)”, In: Annual Book of ASTM Standards, Volume 04.08, 248-259, West Conshohocken, PA., 2003
  7. Schmidt,G.C., “Stratigrafic nomenculature of the Adana region petroleum district”, VII:Petroleum Administration Bulletin, Number:6, pp.47-62, Ankara, 1961
  8. Yetiş,C. ve Demirkol,C., “Adana Baseni Batı Kesiminin Detay Jeoloji Etüdü”, MTA Derleme Rapor No:8037, s.138-146, 1986.