Journals / Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi / 2015 / Cilt: 30 - Sayı: 2

A Computer Aided Control System in Orthopaedic Applications

Ortopedik Uygulamalarda Bilgisayarlı Denetim Sistemi

Pages
93–101
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Furthermore, a 3D simulation belonging to proposed treatment scheme is provided to allow the doctor visually inspect the treatment process before it is initialized

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this work, a computer aided control system enabling effective usage of external fixators that are widely utilized in orthopaedics for various purposes is presented.
📊
Key Findings & Data:With this system, possibility for fixator to fall into a singular position througout the treatment is reduced by cahnging its rod lengths according to various functional models.
💡
Conclusion & Impact:Furthermore, a 3D simulation belonging to proposed treatment scheme is provided to allow the doctor visually inspect the treatment process before it is initialized
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this work, a computer aided control system enabling effective usage of external fixators that are widely utilized in orthopaedics for various purposes is presented. With this system, possibility for fixator to fall into a singular position througout the treatment is reduced by cahnging its rod lengths according to various functional models. Furthermore, a 3D simulation belonging to proposed treatment scheme is provided to allow the doctor visually inspect the treatment process before it is initialized

Özet

Bu çalışmada, ortopedi alanında farklı amaçlar için kullanılmakta olan harici fiksatörlerin etkili kullanımını sağlayacak olan bir bilgisayarlı denetim sistemi tanıtılmıştır. Bu bilgisayar sistemiyle, çubuk boylarını faklı fonksiyonel modellere uygun olacak şekilde değiştirerek, fiksatörün tedavi süresince tekil konuma gelme ihtimali azaltılmıştır. Ayrıca öngörülen tedaviye ait olan 3-boyutlu simülasyon ile doktora, tedaviye başlamadan önce kemiğin izleyeceği yolu görselleştirme olanağı sağlanmıştır

🔖

Cite This Article

AVŞAR, E., AKÇALI, İ. D., AYDIN, A., ÜN, M. K., MUTLU, H., İBRİKÇİ, T., ÖZKAN, C., BİÇER, Ö. (2015). A Computer Aided Control System in Orthopaedic Applications. Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi, Cilt: 30 - Sayı: 2, 93–101. https://ajindex.com/articles/350636

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Stewart, D., 1965. A platform with 6 degrees of freedom, Proc. of The Institutionof Mechanical Engineers, Vol.180, No. 15, pp. 371-386. 2.Burny, F., Bourgouis, R., Donkerwolcke, M., 1982. Elastic Fixation: A Biomechanical Study of the Half-Frame, In Seligson, D., Pope, M.H., (Eds) Concepts in External Fixation, Grune and Stratton, New York, pp:67-77. 3.Behrens, F. 1981. External Skeletal Fixation; In American Academy of Orthopaedic Surgeons Instructional Course Lectures, Vol.30, The CU Mosley Co., St. Louis. 4.Donald, G., Seligson, D., 1982. Fixateur Systems in Current Use in Concepts in External Fixation, (Eds: Seligson, D., Pope, M.) Grune and Stratton, pp:293-308. 5.Pope, M.H., Evans, M., 1982. Design Considerations in External Fixation, in Concept in External Fixation(Eds: Seligson, D., Pope,M.),Grune and Stratton, New York, pp:109 138. 6.Hughes, J.L., Sauer, B.W., 1982. Wagner Apparatus: APortable Traction Device in Concepts inExternalFixation (Eds: Seligson,D., Pope, M.H.) Grune and Stratton, New York, pp:203-218, 7.Letournel, E., 1982. The Judeth Fixateur for Fractures of the Ankle, in Concepts in External Fixation, Grune and Stratton, New York, pp:247-266, 8.Behrens, F., 1982. Unilateral External Fixation ForSevere Lower Extremity Lesions: Experience with the ASIF (AO) Tubular Frame, in Concepts in External Fixation (Eds: Seligson, D. and Pope, M.) Grune and Stratton, New York, pp:279-292. 9.Fernandez, A.A., 1985. External Fixation of the Leg Using Unilateral Biplanar Frames, Arch. Orthop. Trauma Surg., 104 Springer Verlag, pp:182-186. 10.Ilizarov, G., 1992.
  2. Transosseons. Berlin, Springer Verlag. 11.Çakmak, M., Kocaoğlu, M., 1999.
  3. İlizarov Cerrahisi ve Prensipleri, İstanbul. 12.Aydın,A.,İbrikçi, T., Akçalı, İ.D., 2011. A Hybrid Image Processing System for X-ray Images of An External Fixator, Computer Methods in Biomechanics and Biomedical Engineering, 15:7, pp. 753-759, 13.Akçalı, İ.D., ŞahlarM.O., Ün, M.K., Aydın,A.,İbrikçi,T., Esen, R., Gülşen,M.,Bayram, H., 2009. A Mathematical Model in the Implementation of a Stewart Platform as an External Fixator, Medical Physics and Biomedical Engineering World Congress, IFMBE Proceedings,Springer, Vol.25, pp: 708-711, 7-12September, Munich Germany. 14.Mutlu, H., Akçalı, İ.D., Gülşen, M., 2006. A Mathematical Model for the Use of a Gough-Stewart Platform Mechanism as a Fixator. J. of Engineering Mathematics, pp:119-143. 15.Dasgupta, B., Mruthyunjaya, T. S., 1998. Singularity-Free Path Planning for the Stew