Journals / Dicle Tıp Dergisi / 2013 / Cilt: 40 - Sayı: 3

Interpretation of automated blood cell counts

Tam kan sayım çıktılarının yorumlanması

Pages
521–528
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Herein the impact of both pre and post analytic variations on the interpretation of the CBC results with case reports are reviewed in the light of the latest literature.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Complete blood count (CBC) tests are rapid, inexpensive and universally available, and often aid primary clinicians with decision making about patients with several disorders.
📊
Key Findings & Data:Thus the rapid availability of the results of CBC could provide considerable advantage for both patients and clinicians.
💡
Conclusion & Impact:Herein the impact of both pre and post analytic variations on the interpretation of the CBC results with case reports are reviewed in the light of the latest literature.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Complete blood count (CBC) tests are rapid, inexpensive and universally available, and often aid primary clinicians with decision making about patients with several disorders. Thus the rapid availability of the results of CBC could provide considerable advantage for both patients and clinicians. Furthermore, physicians can also avoid unnecessary peripheral blood smear examination using CBC parameters. Many hematology analyzers, which enabled us simultaneously, measure several different CBC parameters, are available for early diagnosis. Herein the impact of both pre and post analytic variations on the interpretation of the CBC results with case reports are reviewed in the light of the latest literature.

Özet

Tam kan sayımı (TKS) testleri hızlı, ucuz ve evrensel olarak kullanılmakta ve çeşitli hastalıklara sahip hastalarda karar aşamasında sorumlu hekime sıklıkla yardımcı olmaktadır. Böylece TKS sonuçlarının hızlı tetkik edilmesi hem hekimler hem de hastalar için önemli bir avantaj sağ- lamaktadır. Ayrıca hekimler TKS parametrelerini kullanarak gereksiz periferik yayma incelemesinden de kaçınabilirler. Çoğu hematoloji cihazlarında aynı anda pek çok parametre değerlendirilerek erken tanı için kullanılabilir. Bu yazıda olgu sunumları ile birlikte TKS sonuçlarının yorumları hakkında en son literatür ışığında analiz öncesi ve sonrası değişkenlerin etkisi gözden geçirilmiştir.

🔖

Cite This Article

KAYA, Z. (2013). Interpretation of automated blood cell counts. Dicle Tıp Dergisi, Cilt: 40 - Sayı: 3, 521–528. https://ajindex.com/articles/349045

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Burns C. Automation in Hematology. In: McKenzie SB, ed. Clinical Laboratory Hematology. New Jersey, Pearson Education, 2004:815-857
  2. Bentley SA, Johnson A, Bishop CA. A parallel evaluation of four automated hematology analysers. Am J Clin Pathol 1993;100:626-632
  3. Buttarello M. Quality specification in haematology: the automated blood cell count. Clin Chim Acta 2004;346:45-54
  4. Zandecki M, Genevieve F, Gerard J, Godon A.Spurious counts and spurious results on haematology analysers: a review. Part I: platelets. Int J Lab Hematol 2007;29:4-20
  5. Zandecki M, Genevieve F, Gerard J, Godon A.Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes. Int J Lab Hematol 2007;29:21-41
  6. Papa F, Rongioletti M, Ventura MD, et al. Blood cell counting in neonates: a comparison between a low volume micromethod and the standard laboratory method. Blood Transfus 2011;9:400-406
  7. Van Cott EM, Lewandrowski KB, Patel S, et al. Comparison of glass K3EDTA versus plastic K2EDTA blood drawing tubes for complete blood counts, reticulocyte counts and white blood cell differentials. Lab Hematol 2003;9:10-14
  8. Wood BL, Andrews J, Miller S, Sabath DE. Refrigerated storage improves the stability of the complete blood cell count and automated differential. Am J Clin Pathol 1999;112:687-695
  9. Gulati GL, Hyland LJ, Kocher W, Schwarting R. Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature. Arch Pathol Lab Med 2002;126:336-342
  10. Mannucci L, Redaelli R, Tremoli E. Effects of aggregating agents and of blood cells on the aggregation of whole blood by impedance technique. Thromb Res 1988;52:143-151
  11. Sanzari M, De Toni S, D’Osualdo A, et al. Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500. Panminerva Med 1998;40:116-125
  12. Briggs C, Carter J, Lee HS, et al. International Council for Standardization in Haematology (ICSH) guideline for worldwide point-of-care testing in haematology with special reference to the complete blood count. Int J Lab Hem 2008;30:105-116
  13. Barnes PW, McFadden SL, Machin SJ, Simson E, International consensus group for hematology. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis. Lab Hematol 2005;11:83-90
  14. Kickler TS. Clinical analy