Dynamic cavernosometry in the diagnosis of impotence

İmpotans tanısında dinamik kavernozometrinin yeri

Pages
23–27
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In case of suspect, the treatment should only be planned after the results obtained by CM/CG are supported by other relevant tests.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Dynamic Cavern.osometry in the Diagnosis of Impotence-Torty-five patients with impotence were evaluated.
📊
Key Findings & Data:Venous leakage was diagnosed in 62 % of the cases by CM/CG.
💡
Conclusion & Impact:In case of suspect, the treatment should only be planned after the results obtained by CM/CG are supported by other relevant tests.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Dynamic Cavern.osometry in the Diagnosis of Impotence-Torty-five patients with impotence were evaluated. Nocturnal penile tumescence (NPT), papaverine test (PVT), penile color Doppler ultrasonography (PCDU) and dynamic cavernosometry/cavernosography (CM/CG) examinations were performed in all cases. Venous leakage was diagnosed in 62 % of the cases by CM/CG. A perfect correlation was established between the results of CM/CG and NPT testing when the infusion rates for maintanence of erection were 30 ml/min or higher. Of the patients with normal PVT, 17 % had infusion rates between 5 and 30 ml/min in CM/CG. While 11 % of the cases with venous leakage as diagnosed by CM/CG, presented normal end-diastolic flow rates with PCDU, 20 % of the cases with normal CM/CG showed high end-diastolic values. CM/CG is not always sufficient for diagnosing venous leakage in impotent patients. In case of suspect, the treatment should only be planned after the results obtained by CM/CG are supported by other relevant tests.

Özet

impotans-yakınması olan 45 hasta incelendi. Tüm hastalarda noktümal penil tümesans (NPT), papaverin testi (PVT), penil renkli Doppler ultrasonografi (PR'DU) ve dinamik kavernozometri/kavernozografi (KM/KG) çalışmaları yapıldı. KM/KG ile olguların % 62'sinde venöz kaçak tanısı kondu. Ereksiyonu devam _ ettirmek için gerekli infüzyon hızı 30 ml/dakika'nın üzerinde olan olgularda NPT ile tam uyum sağlandı. Papaverin testi normal olan olguların % 17'sinde KM/KG ile 5 ile 30 ml/dakika arasında değerler elde edildi. KM/KG ile venöz kaçak bulunan olguların % 11'inde PRDU normal diyastol sonu akım hızları verirken, KM/KG'nin normal olduğu olguların % 20'sinde venöz kaçak saptandı. İmpotan hastalardaki venöz kaçak tanısında kavernozometrinin her zaman tek başına yeterli olmayacağı, bazı kuşkulu olgularda kavemozometri-den alınan sonuçların diğer testlerin sonuçları ile birlikte değerlendirildikten sonra tedavi planının yapılmasının gerekli olduğu düşünüldü.

🔖

Cite This Article

AYDOS, K., YAMAN, Ö., AZER, M., SARICA, K., Anafarta, K. (1997). Dynamic cavernosometry in the diagnosis of impotence. Üroloji Bülteni, Cilt: 8 - Sayı: 1, 23–27. https://ajindex.com/articles/338898