Journals / Retina-Vitreus / 2015 / Cilt: 23 - Sayı: 2

Actual Modern Vitrectomy Machines and Innovations

Güncel Modern Vitrektomi Cihazları ve Yenilikler

Pages
106–114
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This article mentions about actual modern vitrectomy machines and innovations

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Thanks to technological advances in vitrectomy surgery, good results have been obtained for approximately 4 decades with vitreoretinal diseases previously resulting in blindness.
📊
Key Findings & Data:Numerous advances in the technologies and techniques have been made for the establishment and refinement of vitrectomy modality.
💡
Conclusion & Impact:This article mentions about actual modern vitrectomy machines and innovations
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Thanks to technological advances in vitrectomy surgery, good results have been obtained for approximately 4 decades with vitreoretinal diseases previously resulting in blindness. Numerous advances in the technologies and techniques have been made for the establishment and refinement of vitrectomy modality. Development of vitrectomy techniques is the focus in minimal damage to tissues. Of these, enormous advances in minimizing the size of the surgical equipment for carrying out sutureless vitrectomy may be the most remarkable advancement in modern vitrectomy surgery. With the recent advancements, we can now routinely achieve less invasive surgery and consequently have earlier recovery with improved safety. This article mentions about actual modern vitrectomy machines and innovations

Özet

Vitrektomi ameliyatındaki teknolojik gelişmeler sayesinde daha önceleri körlükle sonuçlanan vitreoretinal hastalıklarda yaklaşık 4 dekaddır oldukça iyi sonuçlar alınmaktadır. Teknoloji ve tekniklerdeki birçok ilerlemeler vitrektomi yöntemini yerleştirme ve geliştirme için yapılmaktadır. Vitrektomi tekniklerinin gelişimi dokuya en az hasar üzerine odaklanmaktadır. Sütürsüz vitrektomi yapmak için cerrahi ekipman boyutunu en aza indirmek gibi büyük gelişmeler, modern vitrektomi cerrahisinde en dikkat çekici gelişme olmaktadır. Son gelişmeler sayesinde, artık rutin olarak daha az invaziv cerrahi, daha erken iyileşme ve daha güvenli cerrahiler yapılmaktadır. Bu yazıda güncel modern vitrektomi cihazları ve yeniliklerden bahsedilecektir

🔖

Cite This Article

ÇITIRIK, M., TEKİN, K., CANKURTARAN, V., ŞİMŞEK, M. (2015). Actual Modern Vitrectomy Machines and Innovations. Retina-Vitreus, Cilt: 23 - Sayı: 2, 106–114. https://ajindex.com/articles/308021

References (12)

  1. Mino A, Mitamura Y, Katome T, et al. Case of adult-onset Coats' dise- ase with epiretinal membrane treated with 25-gauge pars plana vitrec- tomy. J Med Invest. 2015;62:85-8.
  2. Oshima Y, Awh CC, Tano Y. Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery. Am J Ophthalmol. 2007;143:166-7.
  3. Çıtırık M, Batman C, Biçer T, ve ark. 23-Gauge transkonjonktival sü- türsüz pars plana vitrektomi. Ret-Vit 2008;16:51-4. 4. Sato T, Emi K, Bando H, et al. Faster recovery after 25-gauge microinci- sion vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy. Clin Ophthalmol. 2012;6:1925-30.
  4. Oshima Y, Wakabayashi T, Sato T, et al. A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy sur- gery. Ophthalmology. 2010;117:93-102.
  5. Gao Q, Mou S, Ge J, et al. A new strategy to replace the natural vitre- ous by a novel capsular artificial vitreous body with pressure-control- valve. Eye (Lond). 2008;22:461-8. Tewari A. The next step in the evolution of vitrectomy surgery techno- logy. Retinal Physician. 2015;12:6-15.
  6. Lima LH, Deboer C, McCormick M, et al. A new dual port cutter system for vitrectomy surgery. Retina. 2010;30:1515-9. Riemann CD. Emerging technology in vitreoretinal surgery. retinal physician. 2014;11:45-52. Teixeira, et al; An experimental protocal of the model to quantify trac- tion applied to the retina by vitreous cutters, IOVS 2010;51:4181-6.
  7. Rossi T, Querzoli G, Angelini G, et al. Introducing new vitreous cutter blade shapes: a fluid dynamics study. Retina. 2014;34:1896-904.
  8. Steel DH, Charles S. Vitrectomy fluidics. Ophthalmologica. 2011;226:27-35.
  9. Hubschman JP, Bourges JL, Tsui I, et al. Effect of cutting pha- ses on flow rate in 20-, 23-, and 25-gauge vitreous cutters. Retina. 2009;29:1289-93.
  10. Diniz B, Ribeiro RM, Fernandes RB, et al. Fluidics in a dual pneu- matic ultra-high-speed vitreous cutter system. Ophthalmologica. 2013;229:15-20. Stalmans P. Enhancing visual acuity. Dev Ophthalmol. 2014;54:23-30. Moshfeghi AA. What's New for Vitrectomy in 2014? A look at 4 state- of-the-art systems and a comparison of features. New Retina MD. 2014:5:15-18. Dugel PU. Proportional reflux hydrodissection. Retina. 2012;32:629-30.
  11. Martinez-Toldos JJ, Hoyos JE. Instrumentation. In Martinez-Toldos JJ, Hoyos JE: Dr Hoyos Step by Step Basic Vitrectomy. New Delhi, India. Jaypee Brothers Medical Publishers. 2006;43-101.
  12. Danis RP, Thompson JT.