Removing of intracoronary thrombus with the balloon of the deployed stent

İntrakoroner trombüsün stent balonu yardımıyla çıkarılması

Pages
52–53
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this report we present a case in which the thrombus that is formed during the interventional procedure was removed out with the balloon of the deployed stent.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Thrombus formation can be encountered during coronary interventions not infrequently.
📊
Key Findings & Data:There are some devices improved in order to remove the thrombus but these methods are generally time consuming and expensive.
💡
Conclusion & Impact:In this report we present a case in which the thrombus that is formed during the interventional procedure was removed out with the balloon of the deployed stent.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Stentler · Tedavi sonucu · Koroner anjiyografi

Abstract

Thrombus formation can be encountered during coronary interventions not infrequently. There are some devices improved in order to remove the thrombus but these methods are generally time consuming and expensive. In this report we present a case in which the thrombus that is formed during the interventional procedure was removed out with the balloon of the deployed stent.

Özet

Koroner girişimler sırasında akut trombüs gelişimi önemli bir sorundur. Oluşan trombüsün çıkarılması için birçok cihaz geliştirilmiştir. Ancak bu cihazlar her zaman elde bulunmamakta, bulunsa da uygulamaları zaman almakta ve maliyeti arttırmaktadır. Bu yazıda kılavuz tel üzerinde oluşan trombüsün stent balonu yardımıyla çıkarıldığı bir olgu sunulmaktadır.

🔖

Cite This Article

KURŞAKLIOĞLU, H., İYİSOY, A., BARÇIN, C., KÖSE, S., DEMİRTAŞ, E. (2002). Removing of intracoronary thrombus with the balloon of the deployed stent. MN Kardiyoloji, Cilt: 9 - Sayı: 1, 52–53. https://ajindex.com/articles/299210

References (1)

  1. DeScheerder I, Sohier J, Wang K et al: Metallic surface treatmer using electrochemical polishing decreases thrombogenicity and neointimal hyperplasia after coronary stent implantation in a porcine model. Eur Heart J 1997; 18 (suppl):153 Hearn JA, Robinson KA, Roubin GS: In-vitro thrombus formation of stent wires: role of metallic composition and heparin coating (abstract). J Am Coll Cardiol 1991; 17 (suppl):302A Baier R: Initial events in interaction of blood with a foreign surface.J Biomed Mat Res1969; 3:191 Chew DP, Bhatt DL, Lincoff AM et al: Defining the optimal activated clotting time during percutaneous intervention: aggregate results from 6 randomized, controlled trials. Circulation 2001; 103:961 Silva JA, Ramee SR: The emergence of mechanical thrombectomy a clot burden reduction approach. Semin Interv Cardiol 2000; 5:137 Brosh D, Rosenchein U: Catheter-based ultrasound thrombolysis a new promising thrombus debulking device for the treatment of intracoronary thrombosis. Semin Interv Cardiol 2000; 5:149 Ischinger T: Thrombectomy with the X-sizer catheter system in thr coronary circulation: initial results from a multicenter study.J Invasive Cardiol 2001; 13:81 Silva JA, Ramee SR, Cohen DJ et al: Rheolytic thrombectomy during percutaneous fevâscularization for acute myocardial infarction: experience with the AngioJet catheter. Am Heart J 2001; 141:3