Journals / Meandros Medical And Dental Journal / 2019 / Cilt: 20 - Sayı: 1

Farklı Bulk Fill Kompozitlerin Su Emilimi, Çözünürlük ve Yüzey Pürüzlülüklerinin Değerlendirilmesi

Evaluation of Water Sorption-solubility and Surface Roughness of Different Bulk Fill Composite Resins

Pages
28–33
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Üretici önerileri doğrultusunda bulk fill kompozitler klinikte geniş bir kullanım alanına sahiptirler.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Bu çalışmanın amacı dört farklı bulk fill kompozit rezin ile bir adet geleneksel akışkan kompozit ve bir adet geleneksel hibrit kompozitin su emilimi, çözünürlük ve yüzey pürüzlülüğü değerlerini karşılaştırmalı olarak incelemektir.
📊
Key Findings & Data:Gereç ve Yöntemler: Üç adet düşük viskoziteli bulk fill kompozit (SureFil SDR flow, X-tra base, Filtek Bulk Fill flow), bir adet yüksek viskoziteli bulk fill kompozit (Tetric EvoCream Bulk Fill), bir adet geleneksel düşük viskoziteli akışkan kompozit (Filtek Ultimate flow) ve bir adet geleneksel hibrit kompozit (Filtek Z250) kullanılarak disk şeklinde örnekler hazırlanıp distile suda 28 gün bekletilmiştir (n=10).
💡
Conclusion & Impact:Üretici önerileri doğrultusunda bulk fill kompozitler klinikte geniş bir kullanım alanına sahiptirler.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Amaç: Bu çalışmanın amacı dört farklı bulk fill kompozit rezin ile bir adet geleneksel akışkan kompozit ve bir adet geleneksel hibrit kompozitin su emilimi, çözünürlük ve yüzey pürüzlülüğü değerlerini karşılaştırmalı olarak incelemektir. Gereç ve Yöntemler: Üç adet düşük viskoziteli bulk fill kompozit (SureFil SDR flow, X-tra base, Filtek Bulk Fill flow), bir adet yüksek viskoziteli bulk fill kompozit (Tetric EvoCream Bulk Fill), bir adet geleneksel düşük viskoziteli akışkan kompozit (Filtek Ultimate flow) ve bir adet geleneksel hibrit kompozit (Filtek Z250) kullanılarak disk şeklinde örnekler hazırlanıp distile suda 28 gün bekletilmiştir (n=10). Örnekler elektronik bir terazide tartılarak kütle kazanım ve kayıp değerlerine göre su emilimi ve çözünürlük değerleri hesaplanmıştır. Daha sonra yüzey pürüzlülüğü ölçümü için profilometre cihazı kullanılmıştır. Elde edilen veriler tek yönlü ANOVA ve Tukey post-hoc testleri ile analiz edilmiştir (p=0,05). Bulgular: Su emilimi ve çözünürlük değerleri arasında pozitif korelasyon tespit edilmiştir (r=0,612; p<0,001), her iki parametre de materyaller arasında belirgin farklılık göstermiştir. Hem düşük hem de yüksek viskoziteli bulk fill kompozitler geleneksellerine kıyasla daha düşük su emilimi ve çözünürlük değerleri göstermiştir. Yüzey pürüzlülüğü açısından ise hem geleneksel hem de bulk fil akışkan kompozler, yüksek dolduruculara göre belirgin şeklide daha düşük pürüzlülük göstermiştir (p<0,05). Sonuç: Su emilimi, çözünürlük ve yüzey pürüzlülüğü değerleri materyale bağlı özelliklerdir ve rezin matriksin yapısından ve doldurucu oranından önemli derecede etkilenirler. Üretici önerileri doğrultusunda bulk fill kompozitler klinikte geniş bir kullanım alanına sahiptirler.

Özet

Objective: This study aimed to investigate and compare the water sorption (WS), solubility (SO) and surface roughness (SR) of four bulk fill resin-based composites (RBCs), a conventional flowable RBC and a conventional hybrid RBC. Materials and Methods: Disc-shaped specimens of 3 low-viscosity bulk fill RBCs (SureFil SDR flow, X-tra base, Filtek Bulk Fill flow), 1 high-viscosity bulk fill RBC (Tetric EvoCream Bulk Fill), 1 conventional low-viscosity flowable RBC (Filtek Ultimate flow) and 1 conventional hybrid RBC (Filtek Z250) (n=10) were prepared and immersed in distilled water for 28 days. Upon removal, specimens were weighed using an electronic scale to determine WS and SO based on weight gain/loss, and surface profilometry was performed to determine SR. Data were analyzed using one-way ANOVA and Tukey’s post-hoc tests (p=0.05). Results: WS and SO showed significant, positive correlations (r=0.612; p<0.001), and both varied significantly among the materials, with WS and SO values of both high-filled and low-filled bulk fill RBCs lower than their conventional counterparts. Moreover, SR values of both bulk and conventional flowable low-fill RBCs were significantly lower in comparison to the high-fill RBCs (p<0.05). Conclusion: WS, SO and SR of RBCs are material-dependent and highly affected by filler loading and resin matrix composition. Bulk fill RBCs can be used in a large variety of clinical situations in line with the manufacturers’ recommendations.

🔖

Cite This Article

GÖNÜLO, N., TUNÇ, E. Ş., ÖZER, S., YILDIZLI, K. (2019). Farklı Bulk Fill Kompozitlerin Su Emilimi, Çözünürlük ve Yüzey Pürüzlülüklerinin Değerlendirilmesi. Meandros Medical And Dental Journal, Cilt: 20 - Sayı: 1, 28–33. https://ajindex.com/articles/282780

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig 2013; 17: 227-35
  2. Dentsply (2011) SDR Scientific Compendium. Retrieved online August 1, 2016 from: http://www.dentsply.de/bausteine. net/f/8883/SCSDRDeTrey110815E.pdf?fd=2
  3. Ivoclar Vivadent (2013) Tetric EvoCeram Bulk Fill Scientific Documentation. Retrieved online August 1, 2016 from: http:// www.ivoclarvivadent.us/en-us/composites/restorativematerials/tetric-evoceram-bulk fill
  4. Ilie N, Bucuta S, Draenert M. Bulk fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013; 38: 618-25
  5. VOCO GmbH (2013) x-tra base. Retrieved online August 1, 2016 from http://www.voco.com/en/product/x-tra_base/index.html. 6. 3M ESPE (2012) Filtek Bulk Fill Flowable Restorative Technical Product Profile. Retrieved online August 1, 2016 from:http:// multimedia.3m.com/mws/media/792321O/filtek-bulk fillflowable-restorative-technical-product-profile.pdf
  6. Söderholm KJ, Mukherjee R, Longmate J. Filler leachability of composites stored in distilled water or artificial saliva. J Dent Res 1996; 75: 1692-9
  7. Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater 1997; 13: 258-69
  8. Sideridou I, Tserki V, Papanastasiou G. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylatebased dental resins. Biomaterials 2003; 24: 655-65
  9. Kwon Y, Ferracane J, Lee IB. Effect of layering methods, composite type, and flowable liner on the polymerization shrinkage stress of light cured composites. Dent Mater 2012; 28: 801-9
  10. Abbas G, Fleming GJP, Harrington E, Shortall AC, Burke FJ. Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments. J Dent 2003; 31: 437-44
  11. Sarrett DC. Clinical challenges and the relevance of materials testing for posterior composite restorations. Dent Mater 2005; 21: 9-20
  12. Al-Ahdal K, Ilie N, Silikas N, Watts DC. Polymerization kinetics and impact of post polymerization on the degree of conversion of bulk fill resin-composite at clinically relevant depth. Dent Mater 2015; 31: 1207-13
  13. Han SH, Sadr A, Tagami J, Park SH. Internal adaptation of resin composites at two configurations: Influence of polymerization shrinkage and stress. Dent Mate