Journals / Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi / 2014 / Cilt: 9 - Sayı: 2

LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi

Pages
177–185
Publication Date
2014-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In previous studies with the results obtained have been compared with the values obtained in this study

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”.
📊
Key Findings & Data:It’s analyzes must be done by determining different dosimetric characteristics and specialty of TL the material.
💡
Conclusion & Impact:In previous studies with the results obtained have been compared with the values obtained in this study
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:LiF · Monte Carlo · foton

Abstract

Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It’s analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It’s possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study

Özet

Özet: Birçok Termolüminesanas (TL) dozimetreleri “personel doz eşdeğerini” ölçmek için farklı alanlarda kullanılmaktadır. TL malzemelerin değişik dozimetrik özelliklerinin ve karakteristiklerinin belirlenerek analizlerinin yapılması gerekmektedir. TL malzemeleri için dedektör cevap fonksiyonlarının enerjiye bağlılığını veren verileri elde etmek, deneysel yöntemler kullanıldığında oldukça güçtür ve büyük hata değerleriyle birlikte ölçülebilmektedir. Bu dedektörler, bilgisayar ortamında modellendiğinde ayrıntılı bilgi almak mümkün olabilmektedir. Bu çalışmada, Mg, Cu, Na ve Si ile katkılanmış TLD olarak kullanılan LiF malzemeleri modellenmiştir. TL dozimetrelerin dedektör cevap fonksiyonlarının enerjiye bağlılığı MCNP Monte Carlo simülasyon yöntemi ile bulunmuştur. Önceden yapılmış çalışmalardan elde edilen sonuçlar ile bu çalışmada elde edilen değerler karşılaştırılmıştır. Anahtar kelimeler: LiF, Monte Carlo, TL, foton The Investigation of The Detector Response Function of The LiF:MgCuNaSi Thermoluminescence Detector Against The Photons In Different Energies By Using Monte Carlo Method Abstract: Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It's analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It's possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study. Key words: LiF, Monte Carlo, TL, photon

🔖

Cite This Article

AYDIN, B., KUMRU, M. N., YEĞİN, G., AYDIN, M. M. (2014). LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi. Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi, Cilt: 9 - Sayı: 2, 177–185. https://ajindex.com/articles/260974

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Tsoulfanidis N., 1983. Measurement and Detection of Radiation, Hemisphere Publishing Corporation, New York, p. 571. Moscovitch M., St. John T.J., Cassata J.R., Blake P.K., Rotunda J.E., Ramlo M., Velbeck K.J., Luo Z., 2006. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: Current status and future directions, Radiation Protection Dosimetry, 119(1-4):248-254.
  2. Freire L., Calado A., Cardoso J.V., Santos L.M., Alves J.G., 2008. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring, Radiation Measurements, 43: 646–650.
  3. Şarer B., Hançerlioğulları A., Übeyli M., 2003. Nükleer Hesaplamalarda Monte Carlo Yönteminin Kullanımı, 8. Ulusal Nükleer Bilimler ve Teknolojiler Kongresi, Ekim 2003,
  4. Kayseri. Briesmeister, J.F., Editor, 2000. MCNP- A General Monte Carlo N-Particle Transport Code System. LA-12625-M, Version C Horowits Y.S., 1981. Thetheorical and microdosimetric basis of thermolüminescence and applications to dosimetry, Physical Medical Biology, 26, 4, 765-824.
  5. Das R.K., Li Z., Perera H., Williamson J.F., 1996.Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts, Physical Medical Biology, 41: 995-1006.
  6. Jung, H., Lee, K.J., and Kim, J.L., 2003. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon Şelds, Applied Radiation and Isotopes, 59: 87–93.
  7. Hranitzky C., Stadtmann H., Olko P., 2006. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for x-rays and their application to Monte Carlo simulations of dosimeter response, Radiation Protection Dosimetry, 119(1–4): 483–486. Mehmet N. Kumru e-posta: [email protected] Gültekin Yeğin e-posta: [email protected] M. Mustafa Aydın e-posta: [email protected]