Journals / Hacettepe Journal of Biology and Chemistry / 2018 / Cilt: 46 - Sayı: 2

Simultaneous Determination of Three Phenolic Compounds in Water Samples by Pre-column Derivatization Coupled with Reversed-Phase High Performance Liquid Chromatography

Pages
147–157
Publication Date
2018-06-03
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The method was applied to the analysis of phenols in different water samples.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:I n this study, a sensitive and accurate method for simultaneous separation and determination of three phenolic compounds (phenol, m-cresol and resorcinol) in water by revesed-phase high performance liquid chromatography using uv-visible detection has been described.
📊
Key Findings & Data:Pre-column derivatization with 4-aminoantipyrine is used for the seperation and determination phenol, m-cresol and resorcinol in water.
💡
Conclusion & Impact:The method was applied to the analysis of phenols in different water samples.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Phenols · derivatization · reversed-phase liquid chromatography

Abstract

I n this study, a sensitive and accurate method for simultaneous separation and determination of three phenolic compounds (phenol, m-cresol and resorcinol) in water by revesed-phase high performance liquid chromatography using uv-visible detection has been described. Pre-column derivatization with 4-aminoantipyrine is used for the seperation and determination phenol, m-cresol and resorcinol in water. The derivatives formed within 5 min were extracted with chloroform and then analyzed by liquid chromatography with UV-visible detection at 440 nm. Chromatographic separation was performed using a reversed-phase column and acetonitrile-water (45:55%, v/v) as the mobile phase. The three derivatives were elueted in 13 min. The detection limits of phenol, m-cresol and resorcinol in a standard water sample were between 0.07 and 0.09 μg.L-1 for 100 mL respectively. The recoveries of the derivatives from pure water were betweeen 97.1-102.3% within relative standard deviations of 2.3-4.7%. The method was applied to the analysis of phenols in different water samples.

🔖

Cite This Article

ASAN, A., KONANÇ, M., AKMEŞE, B. (2018). Simultaneous Determination of Three Phenolic Compounds in Water Samples by Pre-column Derivatization Coupled with Reversed-Phase High Performance Liquid Chromatography. Hacettepe Journal of Biology and Chemistry, Cilt: 46 - Sayı: 2, 147–157. https://ajindex.com/articles/255646

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. M.L. Soto, A. Moure, H. Domínguez, J.C. Parajó, Recovery, concentration and purification of phenolic compounds by adsorption: a review, J. Food Eng., 105 (2011) 1-27.
  2. A. Penalver, E. Pocurrull, F. Borrull, R.M. Marce, Solidphase microextraction coupled to high-performance liguid chromatography to determine phenolic compounds in water samples, J. Chromatogr. A, 953 (2002) 79-87.
  3. H. Xu, Y. Liao, J. Yao, Development of a novel ultrasound-assisted head-space liquid-phase microextraction and its application to the analysis of chlorophenols in real aqueous samples, J. Chromatogr. A, 1167 (2007) 1-8. EPA. Methad 604, Phenols, Part VIII, 40 CFR part 136. US Environmental Protection Agecy, 26 july 2014.
  4. M. L. Barrico, C. Nabais, M.J. Martins, H. Freitas, Sources of phenolic compounds in two catchments of southern Potugal-effect of season, land use and soil type, Chemosphere, 65 (2006) 482-488.
  5. A.R. Sousa, M.A. Trancoso, Validation of an environmental friendly segmented flow method for the determination of phenol index in waters as alternative to the conventional one, Talanta, 79 (2009) 769-803.
  6. S. Lacorte, A. Latorre, D. Barcelo, A. Rigol, A. Malmiqvist, T. Welander, Organic compounds in papwer-mill process waters and effluents, Trends Anal. Chem., 22 (2003) 725-737.
  7. J. Michalowich, W. Duda, Phenols-sources and toxicity, Pol. J. Environ. Stud., 16 (2007) 347-362.
  8. K.O. Lupetti, F.R.P. Rocha, O. Fatibello-Filho, An immproved flow system for phenols determination explieting multicommutation and long pathlength spectrophotometry, Talanta, 62 (2004) 463-469.
  9. A. Asan, I. Isildak, Determination of major phenolic compounds in water by reversed-phase liquid chromatography after pre-column derivatization with benzoyl chloride. J. Chromatogr. A, 988 (2003) 145- 149. L. Zhao, K.H. Lee, Determination of phenols in water using.Liquid phase microextraction with back extraction combined with high-prformance liquid chromatography, J. Chromatogr. A, 931 (2001) 95-105.
  10. H. Bagheri, A. Mohammadi, A. Salemi, On-line trace enrichment of phenolic compounds from water using a pyrrole-based polymer as the solid-phase extraction sorbent coupled with high-performance liquid chromatography, Anal. Chim. Acta, 513 (2004) 445-449.
  11. G. Marrubini, E. Calleri, T. Coccini, A.F. Castoldi, L. Manzo, Direct analysis of phenol, catechol and hydroquinone in human urine by coupled-column HPLC with fluorimetric detection, Chromatographia, 62 (2005) 25-31.
  12. N. Sharma, A. Jain, V. Kumari Singh, K.K. Verma, Soli