Journals / Güncel Retina Dergisi / 2017 / Cilt: 1 - Sayı: 1

Adaptive Optics In Retinal Imaging

Retinal Görüntülemede Adaptif Optiks

Pages
85–90
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

These studies indicate that AO will begin to be used more widely in retina clinics in the near future

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Adaptive Optics (AO) is a new instrument that provides high resolution imaging of retinal microstructures by correcting the aberrations.
📊
Key Findings & Data:AO has been used to integrate with the different retinal imaging systems such as, fundus camera, scanning laser ophthalmoscopy, fundus angiography and optic coherence tomography.
💡
Conclusion & Impact:These studies indicate that AO will begin to be used more widely in retina clinics in the near future
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Adaptive Optics (AO) is a new instrument that provides high resolution imaging of retinal microstructures by correcting the aberrations. AO has been used to integrate with the different retinal imaging systems such as, fundus camera, scanning laser ophthalmoscopy, fundus angiography and optic coherence tomography. As a result, retinal images with nearly diffraction-limited resolution that allows the exploration of the cellular details of the retina. AO is still at early stages in ophthalmology and has some limitations. However recent times there are a lot of studies evaluating the clinical applications and advantages of AO. These studies indicate that AO will begin to be used more widely in retina clinics in the near future

Özet

Adaptif Optiks (AO), aberasyonları düzelterek retinal mikro yapıların yüksek çözünürlükte görüntülenebilmesine imkân veren yeni bir cihazdır. AO, fundus kamera, taramalı lazer oftalmoskop, fundus anjiyografi ve optik koherens tomografi gibi farklı retinal görüntüleme sistemlerine entegre edilerek kullanılabilir. Sonuçta, retinanın hücresel düzeyde incelenmesine imkân verebilecek, difraksiyon limiti sınırlarında retinal görüntü alınabilmesi mümkün olabilmektedir. AO uygulamaları oftalmolojide halen erken evrelerdedir ve bazı kısıtlılıkları mevcuttur. Bunun yanında son dönemlerde, AO uygulamalarının avantajlarını ve kliniğe uygulama alanlarını irdeleyen çok sayıda çalışma yayınlanmaktadır. Bu çalışmalar AO uygulamalarının yakın bir gelecekte retina kliniklerinde çok daha yaygın bir şekilde kullanılmaya başlayacağını göstermektedir

🔖

Cite This Article

UĞURLU, N., TAŞLIPINAR, A. G., ŞENGÜN, A. (2017). Adaptive Optics In Retinal Imaging. Güncel Retina Dergisi, Cilt: 1 - Sayı: 1, 85–90. https://ajindex.com/articles/224237

References (18)

  1. Jackman WT and Webster JD. On photographing the retina of the living human eye. The Philadelphia Photographer. 1886; 23: 340–341
  2. Jackman W, Webster J. photographing the retina of the living human eye. Photogr News. 1886; 23: 340–341
  3. Novotny HR, Alvis DL. A method of photographing fluorescence in circulating blood in the human retina. Circulation. 1961; 24: 82–6
  4. Roorda A. Adaptive optics ophthalmoscopy. J Refract Surg. 2000; 16(5):S602–S607
  5. Cole ED, Novais EA, Louzada RN, Waheed NK. Contemporary retinal imaging techniques in diabetic retinopathy: a review. Clin Exp Ophthalmol. 2016; 44: 289–299
  6. Morgan JIW. The fundus photo has met its match: optical coherence tomography and adaptive optics ophthalmoscopy are here to stay. Ophthalmic Physiol Opt. 2016; 36: 218–239
  7. Babcock HW. The possibility of compensating astronomical seeing. Publ Astron Soc Pac. 1953; 65: 229–236
  8. Booth M, Andrade D, Burke D and et al. Aberrations and adaptive optics in super-resolution microscopy. Microscopy. 2015: 64(4); 251–261
  9. Battu R, Dabir S, Khanna A, Kumar AK, Roy AS. Adaptive optics imaging of the retina. Indian J Ophthalmol. 2014 Jan; 62(1): 60–65
  10. Jonnal RS, Kocaoglu OP, Zawadzki RJ, et al. A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future. Invest Ophthalmol Vis Sci. 2016; 57(9): OCT51-68
  11. Plat BC, Shack R. History and principles of Shack-Hartmann wave front sensing. J. Ref. Surg. 2001; 17(5): 573–577
  12. Iglesias I, Ragazzoni R, Julien Y, Artal P. Extended source pyramid wave front sensor for human eye. Optics Express. 2002; 10(9):419–428
  13. Shirai T. Liquid-crystal adaptive optics based on feedback interferometry for high-resolution retinal image. Appl. Opt. 2002; 41(19):403–423
  14. Liang J, Williams DR, Miller D. Supernormal vision and high-resolution retinal imaging through adaptive optics. J Opt Soc Am A. 1997; 14: 2884–2892
  15. Bedggood P, Metha A. Variability in bleach kinetics and amount of photo pigment between individual foveal cones. Invest Ophth Vis Sci. 2012; 53:3673–3681
  16. Roorda A, Romero-Borja F, Donnelly WJ, Queener H, Hebert TJ, Campbell MCW. Adaptive optics scanning laser ophthalmoscopy. Opt Express. 2002; 10: 405–412
  17. Dubra A, Sulai Y. Reflective afocal broadband adaptive optics scanning ophthalmoscope. Biomed Opt Express. 2011; 2:1757–1768
  18. Chui TYP, Mo S, Krawitz B, et al. Human retinal microvascular imaging using adaptive optics sc