Current Developments in Vitrectomy: Hypersonic Vitrectomy and 3-Dimensional (3D) Vitrectomy Surgery

Vitrektomide Güncel Gelişmeler: Hipersonik Vitrektomi ve 3-Boyutlu (3D) Vitrektomi Cerrahisi

Pages
327–332
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Improvements in the imaging and vitrectomy systems have made the operation process more practical and comfortable, and have led to significant success in the postoperative period. 3D imaging systems, which entered into ophthalmology practice in 2008, and hypersonic vitrectomy systems, which started to practice ophthalmology as a new technology in 2017, have gained new perspectives in vitrectomy surgery.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:With the advancing technology in vitrectomy surgery, revolutionary changes have occurred.
📊
Key Findings & Data:With the advancing technology in vitrectomy surgery, revolutionary changes have occurred.
💡
Conclusion & Impact:Improvements in the imaging and vitrectomy systems have made the operation process more practical and comfortable, and have led to significant success in the postoperative period. 3D imaging systems, which entered into ophthalmology practice in 2008, and hypersonic vitrectomy systems, which started to practice ophthalmology as a new technology in 2017, have gained new perspectives in vitrectomy surgery.
🔬Design:Research Article
📍Scope:2008 Verileri
⚙️Variables:Domain Parameters

Abstract

With the advancing technology in vitrectomy surgery, revolutionary changes have occurred. Improvements in the imaging and vitrectomy systems have made the operation process more practical and comfortable, and have led to significant success in the postoperative period. 3D imaging systems, which entered into ophthalmology practice in 2008, and hypersonic vitrectomy systems, which started to practice ophthalmology as a new technology in 2017, have gained new perspectives in vitrectomy surgery.

Özet

Vitrektomi cerrahisinde gelişen teknolojiyle beraber devrimsel değişiklikler yaşanmıştır. Görüntüleme ve vitrektomi sistemlerindeki gelişmeler, ameliyat sürecinin daha pratik ve konforlu olmasını sağlamakla birlikte ameliyat sonrasıda önemli başarılar elde edilmesini sağlamıştır. 2008 yılında oftalmoloji pratiğine giren 3D görüntüleme sistemleri ve 2017 yılında yeni bir teknoloji olarak oftalmoloji pratiğine girmeye başlayan hipersonik vitrektomi sistemleri, vitrektomi cerrahisinde yeni bakış açıları kazandırmıştır.

🔖

Cite This Article

ÇAKMAK, H., YAŞAR, M. (2022). Current Developments in Vitrectomy: Hypersonic Vitrectomy and 3-Dimensional (3D) Vitrectomy Surgery. Güncel Retina Dergisi, Cilt: 5 - Sayı: 4, 327–332. https://ajindex.com/articles/528172

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Dodo T, Okuzawa Y, Baba N. Trans-pupillary resection of vitreous body opacity. Ganka Ophthalmology. 1969;11(1):38. Kasner D, Miller GR, Taylor WH, Sever R, Norton E. Surgical treatment of amyloidosis of the vitreous. Transactions-American Academy of Ophthalmology and Otolaryngology American Academy of Ophthalmology and Otolaryngology. 1968;72(3):410-8.
  2. O'Malley C, Heintz SR. Vitrectomy with an alternative instrument system. Annals of ophthalmology. 1975;7(4):585-8, 91-4.
  3. Machemer R, Hickingbotham D. The three-port microcannular system for closed vitrectomy. American journal of ophthalmology. 1985;100(4):590-2. Fujii GY, de Juan Jr E, Humayun MS, Chang TS, Pieramici DJ, Barnes A, et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology. 2002;109(10):1814-20. Eckardt C. Transconjunctival sutureless 23-gauge vitrectomy. Retina. 2005;25(2):208- 11. Oshima Y, Wakabayashi T, Sato T, Ohji M, Tano Y. A 27–gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery. Ophthalmology. 2010;117(1):93-102. e2. Littmann H. A new surgical microscope. Klinische Monatsblatter fur Augenheilkunde und fur augenarztliche Fortbildung. 1954;124(4):473-6.
  4. Parel J-M, Machemer R, Aumayr W. A New Concept for Vitreous Surgery: 5. An Automated Operating Microscope. American journal of ophthalmology. 1974;77(2):161-8. Machemer R. Vitrectomy, a pars plana approach. Trans Am Acad Ophthaimol. 1971;75:813-20. Charles S. The history of vitrectomy: innovation and evolution. Retina Today. 2008;2008:27-9.
  5. De Oliveira PRC, Berger AR, Chow DR. Vitreoretinal instruments: vitrectomy cutters, endoillumination and wide-angle viewing systems. International journal of retina and vitreous. 2016;2(1):28. Mariotti C, Nicolai M, Saitta A, Orsini E, Viti F, Skrami E, et al. Standard Cut Rate 25-Gauge Vitrectomy Versus Ultrahigh-Speed 25-Gauge System in Core Vitrectomy. Retina. 2016;36(7):1271-4. Pavlidis M. Two-dimensional cutting (TDC) vitrectome: in vitro flow assessment and prospective clinical study evaluating core vitrectomy efficiency versus standard vitrectome. Journal of ophthalmology. 2016;2016: 3849316. Stanga PE, Pastor-Idoate S, Zambrano I, Carlin P, McLeod D. Performance analysis of a new hypersonic vitrector system. PloS one. 2017; 12(6):e0178462. O’Daly BJ, Morris E, Gavin GP, O’Byrne JM, McGuinness GB. High-power low-frequency ultrasound: A review of tissue dissection and ablation in medicine and