AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Measured values have been found to be in close range with the manufacturer’s catalog data.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a new method for the measurement of figure of merit, Z, of a thermoelectric module has been introduced.
📊
Key Findings & Data:Then, the realized new test system has been used to measure the Z of a standard thermoelectric module (Melcor CP 1.4-127-10L).
💡
Conclusion & Impact:Measured values have been found to be in close range with the manufacturer’s catalog data.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Termoelektrik modül · Figure of Merit · test sistemi

Abstract

In this study, a new method for the measurement of figure of merit, Z, of a thermoelectric module has been introduced. The new method depends on the measurement of thermoemf, voltage and hot side temperature of the module. A new microcontroller test system has been designed and realized using this new method. Then, the realized new test system has been used to measure the Z of a standard thermoelectric module (Melcor CP 1.4-127-10L). Measured values have been found to be in close range with the manufacturer’s catalog data.

Özet

Bu çalışmada, bir termoelektrik modülün soğutma performansını gösteren kalite faktörü (figure of merit - Z) parametresinin belirlenmesi için termoemk, gerilim ve sıcak yüzeyin sıcaklığının ölçümüne dayalı yeni bir yöntem kullanılmıştır. Bu yönteme göre çalışan yeni bir mikrodenetleyici test sistemi gerçekleştirilmiştir. Yeni test sistemiyle Melcor firmasının ürettiği standart (CP 1.4-127-10L) modülün Z değeri ölçülmüştür. Bu değerler Melcor tarafından verilen Z değerleri ile kıyaslanmıştır. Bu değerler birbirine oldukça yakın çıkmıştır.

🔖

Cite This Article

AHISKA, R., CİYLAN, B., SAVAŞ, Y., GÜLER, İ. (2013). A NEW TEST METHOD AND SYSTEM FOR THE MEASUREMENT OF Z-PARAMETER OF STANDARD PELTIER MODULES. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 19 - Sayı: 4, 467–473. https://ajindex.com/articles/21305

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Heylen, A. E. D., “Figure of Merit determination of Thermo-electric Modules”, Energy Conversion, Cilt 15, pp 65-70, 1975.
  2. Bowley A E, Inst A., Cowles L E J., Williams G J., Goldsmid H J, Inst F, “Measurement of the figure of merit of a thermoelectric material”, Journal of Scientific Instruments, Cilt 38 pp -435, 1961. Harman T. C., “Special Techniques for measurement of thermoelectric properties”, J. Appl. Phys., Cilt 29, pp 1373-1379, 1958. Goldsmid H. J., “A simple technique for determining the Seebeck coefficient of thermoelectric materials”, Journal of Physics E: Scientific Instruments, Cilt 19, pp 921-922, - Buist R. J., “Methodology for testing thermoelectric materials and devices” CRC Handbook of Thermoelectrics Editör: Rowe, D. M., CRC Pres. Inc.,Florida, ABD., 189-209, - Summasekera G. U.,Grigorian L., Eklund P. C., “Low-Temperature thermoelectrical power measurement using analogue subtraction”, Measurement of Science and Technology, Cilt, pp 273-277, 2000. Waclawek W., and Zabkowska M., “Apparatus for the measurement of thermoelectrical properties”, Journal of Physics E: Scientific Instruments, Cilt 14, pp 618-620, 1981.
  3. Huang B. J., Chin C. J., Duang C. L., “A design method of thermoelectric cooler” International Journal of Refrigeration, Cilt 23, pp 208-218, - Min G., Rowe, D. M., “Improved model for calculating the coefficient of performance of a Peltier module”, Energy conversion and management, Cilt 41, pp 163-171, 2000.
  4. Min G., Rowe D. M., “A novel principle allowing rapid and accurate measurement of a dimensionless thermoelectric figure of merit”, Measurement of Science and Technology, Cilt, pp 1261-1262, 2001. http://www.melcor.com homepage of Melcor, USA. Xuan X. C., Ng K. C., Yap C., Chua H. T., “A general model for studying effects of interface layers on thermoelectric devices performance”, International Journal of Heat and Mass Transfer, Cilt 45, pp 5159–5170, 2002. Xuan X. C., “Investigation of thermal contact effect on thermoelectric coolers”, Energy conversion and management, Cilt 44, pp 399-, 2003.
  5. Ioffe A. F., Polucenie holoda Poluprovodnikovıe Termoelementı ed P V Gulteif Moskov Pres., Moskov, Rusia, 1960.