Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2006 / Cilt: 21 - Sayı: 2

INVESTIGATION OF SUBCOOLING AND SUPERHEATING EFFECTS IN REFRIGERATION SYSTEMS IN TERMS OF THERMOECONOMICS

BUHAR SIKIŞTIRMALI SOĞUTMA SİSTEMLERİNDE AŞIRI SOĞUTMA VE AŞIRI KIZDIRMA ETKİSİNİN ISIL EKONOMİK AÇIDAN İNCELENMESİ

Pages
387–393
Publication Date
2013-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the present study, optimum conditions for the optimum heat exchanger area and optimum system efficiency are determined.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, subcooling and superheating heat exchangers of vapor compressed refrigeration system were investigated in terms of thermoeconomics for two different refrigerants and optimum working conditions were determined.
📊
Key Findings & Data:Analyses were carried out for refrigerant R22 and alternative of it, refrigerant R407c.
💡
Conclusion & Impact:In the present study, optimum conditions for the optimum heat exchanger area and optimum system efficiency are determined.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Isıl ekonomik en iyileme · yapısal bağ katsayıları · aşırı kızdırma

Abstract

In this study, subcooling and superheating heat exchangers of vapor compressed refrigeration system were investigated in terms of thermoeconomics for two different refrigerants and optimum working conditions were determined. Coefficient of structural bonds was used as thermoeconomic optimization method. Analyses were carried out for refrigerant R22 and alternative of it, refrigerant R407c. As a result, optimum areas of subcooling and superheating heat exchangers are determined in relation to economics and working performance. For a refrigeration system design, decrease of heat exchanger area, affects the system cost as a decrease. However, decrease of heat exchanger area, causes a decrease in efficiency value of system. In the present study, optimum conditions for the optimum heat exchanger area and optimum system efficiency are determined.

Özet

Bu çalışmada, teorik bir buhar sıkıştırmalı soğutma sisteminin aşırı kızdırma ve aşırı soğutma ısı değiştiricilerinin, farklı iki soğutucu akışkan için ısıl ekonomik yönden analizi yapılmış ve sistemin en iyi çalışma şartları belirlenmiştir. Isıl ekonomik en iyileme metodu olarak, yapısal bağ katsayıları metodukullanılmıştır. Analizler, R22 soğutucu akışkanı ve buna alternatif olarak R407c soğutucu akışkanı için yapılmıştır. Sonuç olarak, aşırı kızdırma ve aşırı soğutma ısı değiştiricilerinin ekonomik ve çalışma performansıaçısından en iyi alanları tespit edilmiştir. Bir soğutma sistemi tasarımında, ısı değiştiricisi alanının azalması, sistem maliyetini düşürür. Fakat ısı değiştiricisi alanının düşürülmesi sistem verimini de düşürmektedir. Yapılan çalışmada, ısı değiştiricisi alanının, ve sistem veriminin en iyi olduğu şartlar belirlenmiştir.

🔖

Cite This Article

KIZILKAN, Ö., SELBAŞ, R., ŞENCAN, A. (2013). INVESTIGATION OF SUBCOOLING AND SUPERHEATING EFFECTS IN REFRIGERATION SYSTEMS IN TERMS OF THERMOECONOMICS. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 21 - Sayı: 2, 387–393. https://ajindex.com/articles/21141

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Çengel, A.Y., Boles, A.M, Thermodynamics: An Engineering Approach, McGraw-Hill, New York, A.B.D., 1994.
  2. Ashrae, Fundamentals, American Society of Heating Refrigerating and Air Conditioning Engineers Inc., Atlanta, A.B.D., 1993.
  3. Dossat, R.J., Principles of Refrigeration, Prentice Hall, New Jersey, A.B.D., 1997.
  4. Bejan, A., Advanced Engineering Thermodynamics, John Wiley and Sons, New York, A.B.D., 1997.
  5. Kotas, T.J., The Exergy Method of Thermal Plant Analysis, Butter-Worths, London, England, 1985.
  6. Koçoğlu, A., Thermo-economic Optimization of a Single State Heat Pump, Master Thesis, M.E.T.U. The Graduate School of Natural and Applied Sciences, 1993.
  7. Chen, J., “Thermodynamic and Thermoeconomic Analysis of an Irreversible Combined Carnot Heat Engine System”, International Journal of Energy Research, Cilt 25, 413-426, 2001.
  8. Dingeç, H., Thermoeconomic Optimization of Simple Refrigerators, Master Thesis, M.E.T.U. The Graduate School of Natural and Applied Sciences, 1996.
  9. Sciubba, E., “Beyond Thermoeconomics? The Concept of Extended Exergy Accounting and Its Application to the Analysis and Design of Thermal Systems”, Exergy, An International Journal, Cilt 1, No 2, 68-84, 2001.
  10. Wall, G., “Thermoeconomic Optimization of a Heat Pump System”, Physical Resource Theory Group, Report No: 85-5, Göteborg. Sweden, - Zhang, G.Q., Wang, L., Liu, L., Wang, Z., “Thermoeconomic Optimization of Small Size Central Air Conditioner”, Applied Thermal Engineering, Cilt 24, No 4, 471-485, 2004.
  11. Al-Otaibi, A.D., Dincer, I., Kalyon, M., “Thermoeconomic Optimization of Vapor- Compression Refrigeration Systems”, Int. Comm. Heat Mass Transfer, Cilt 31, No 1, 95-, 2004. D’Accadia, M.D., Fichera, A., Sasso, M., Vidiri, M., “Determining the Optimal Configuration of a Heat Exchanger (With a Two Phase Refrigerant) Using Exergoeconomics”, Applied Energy, Cilt, No 3, 191-203, 2002. D’accadia, M.D., Sasso M., “Exergetic Cost and Exergoeconomic Evaluation of Vapour- Compression Heat Pumps”, Energy, Cilt 23, No, 937-942, 1998. D’Accadia, M.D., Rossi, F., “Thermoeconomic Optimization of a Refrigeration Plant”, Int. J. Refrig., Cilt 21, No 1, 42-54, 1998.
  12. Chen, Q., Prasad, R.C. “Simulation of a Vapour- Compression Refrigeration Cycle using HFC a and CFC12”, Int. Comm. Heat Mass Transfer, 26(4), 513-521, 1999.
  13. Yumrutaş, R., Kunduz, M., Kanoğlu, M. “Exergy Analysis of Vapor Compression Refrigeration Systems”, Exergy, an International Journal, (4), 266-274, 2002.
  14. Kizilkan, Ö. “Examination of Superheatin