Journals / Journal of Turkish Spinal Surgery / 2015 / Cilt: 26 - Sayı: 1

ERİŞKİN TÜRK TOPLUMUNDA ODONTOİD VİDA UZUNLUĞU: MORFOMETRİK BİR ÇALIŞMA

LENGTH OF THE TRAJECTORY OF ANTERIOR ODONTOID SCREW IN ADULT TURKISH POPULATION: MORPHOMETRIC STUDY

Pages
3–5
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Overall average length is 3.52±0.81 cm.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Anterior placement of a screw for fixation of an odontoid fracture is performed to maintain axial rotation at the C1, C2 level.
📊
Key Findings & Data:Measurement of the trajectory length was performed on midsagittal T1-W sequence of MRI.
💡
Conclusion & Impact:Overall average length is 3.52±0.81 cm.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Anterior placement of a screw for fixation of an odontoid fracture is performed to maintain axial rotation at the C1, C2 level. This morphometric study was performed to determine the length of anterior odontoid screw trajectory in adult Turkish population. Measurement of the trajectory length was performed on midsagittal T1-W sequence of MRI. Overall average length is 3.52±0.81 cm. Commonly used 35 mm screws are suitable for approximately half of the population

Özet

C1, C2 düzeyinde yapılacak sabitlemede aksiyal rotasyonu korumak için anterior odontoid vidası kullanılmaktadır. Bu morfometrik çalışma erişkin Türk toplumunda uygun anterior odontoid vidası boyunu belirlemektir. Vida yolu ölçümleri T1-A midsagittal MRG üzerinde yapılmıştır. Vida yolunun ortalama uzunluğu 3.52±0.81 cm. dir. Sıklıkla kullanılan 35 mm. vidalar toplumun yarısı ıçın uygun olduğu belirlenmiştir

🔖

Cite This Article

ER, U., BENLİ, İ. T. (2015). ERİŞKİN TÜRK TOPLUMUNDA ODONTOİD VİDA UZUNLUĞU: MORFOMETRİK BİR ÇALIŞMA. Journal of Turkish Spinal Surgery, Cilt: 26 - Sayı: 1, 3–5. https://ajindex.com/articles/208764

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Anderson LD, D' Alonzo RT. Fractures of the odontoid process of the axis. J Bone Joint Surg 1974; 56-A: 1663-1674
  2. Bohler J. Anterior stabilization for acute fractures and nonunions of the dens. J Bone Joint Surg 1982; 62-A: 18-27
  3. Chang KW, Liu YW, Cheng PG, Suen KL, Chung WL, Chen UL, Liang PL. One Herbert double-threaded compression screw fixation of displaced type II odontoid fractures. J Spin Disord 1994; 7; 62-69
  4. Esses SI, Bednar DA. Screw fixation of odontoid fractures and nonunions. Spine 1991; 16(Suppl 10): S483-485.5- Feng G, Wendlandt R, Spuck S, Schulz AP. One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures. Clin Ortop Relat Res 2012; 470: 2021-2028 6- Husby J, Sorensen KH. Fracture of the odontoid process of the axis. Acta Orthop Scand 1974; 45: 182-192
  5. Jenkins JD, Coric D, Branch CL. A clinical com-parison of one and two screw odontoid fixation. J Neuro-surg 1998; 89: 366-370
  6. Kulkarni AG, Shah SM, Marvah RA, Hanagandi PB, Talwar IR. CT based evaluation of odontoid mor-phology in the Indian population. Indian J Ortop 2013; 47(3): 250-254 9- Maak TG, Grauer JN. The contemporary treat-ment of odontoid injuries. Spine 2006; 31(11 Suppl): S53-60
  7. Nakanishi T, Sasaki T, Tokita N, Hirabayashi K. Internal fixation for the odontoid fracture. Orthop Trans1982; 6: 176 11- Sasso R, Doherty BJ, Crawford MJ, Heggeness MH. Biomechanics of odontoid fracture fixation. Spine1993; 18: 1950-1953
  8. Vaccaro AR, Cotler JM. Upper cervical spine injuries in the adult. In: An S Howard (ed.) Principles and techniques of spine surgery. Baltimore, Williams and Wilkins. 1998; pp: 331-358