⚡ TL;DR(Too Long; Didn't Read)

Results: The error rates were found to be 77.8%, 19.26% and 2.92% in preanalytical, analytical and postanalytical phases retrospectively.It has been evaluated that, hemolysed samples were found to be the most frequent error between 2006 and 2014

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: Preanalytical errors constitute more than 70% of all errors occured in clinical laboratories.
📊
Key Findings & Data:Most of the pre-analytical errors occur during patient preparation, sample collection, sample transportation and preparation and sample storage.Methods:Laboratory error recorded between 2006-2014 were analyzed retrospectively.
💡
Conclusion & Impact:Results: The error rates were found to be 77.8%, 19.26% and 2.92% in preanalytical, analytical and postanalytical phases retrospectively.It has been evaluated that, hemolysed samples were found to be the most frequent error between 2006 and 2014
🔬Design:Makale
📍Scope:2006-2014 Verileri
⚙️Variables:Pareto · Hata · ISO 15189

Abstract

Purpose: Preanalytical errors constitute more than 70% of all errors occured in clinical laboratories. Most of the pre-analytical errors occur during patient preparation, sample collection, sample transportation and preparation and sample storage.Methods:Laboratory error recorded between 2006-2014 were analyzed retrospectively. Pre-analytic, analytic and post-analytic errors were evaluated after Pareto analysis. Results: The error rates were found to be 77.8%, 19.26% and 2.92% in preanalytical, analytical and postanalytical phases retrospectively.It has been evaluated that, hemolysed samples were found to be the most frequent error between 2006 and 2014

Özet

Amaç: Tıbbi laboratuvar hatalarının %70’inden fazlasını pre-analitik hatalar oluşturmaktadır. Preanalitik hataların çoğu; hastaların hazırlanması, örneklerin toplanması, transportu, hazırlanması ve saklanması süreçlerinde olmaktadır. Yöntem: Retrospektif olarak 2006-2014 yıları arasında kayıt edilen laboratuvar hataları incelenmiştir. Pareto analizi ile pre-analitik, analitik ve post-analitik hatalar değerlendirilmiştir. Bulgular ve Sonuç: Pre-analitik, analitik ve post-analitik süreçler için hata oranları sırasıyla; %77.8, %19.26 ve %2.92 olarak bulunmuştur. 2006-2014 yılları arasındaki en sık laboratuvar hatasını hemolizli örnek olduğu tespit edilmiştir.

🔖