Journals / Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi / 2020 / Cilt: 26 - Sayı: 2

Pneumothorax Caused by Airway Extubation Catheter in a Difficult Intubation Case

Zor Entübasyon Olgusunda Hava Yolu Ekstübasyon Kateterinin Yol Açtığı Pnömotoraks

Pages
106–110
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this case, we present our experience with awake fiberoptic nasotracheal intubation, extubation performed with an airway exchange catheter in a patient who subsequently developed pneumothorax.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In the expected cases of difficult intubation, awake fiberoptic nasotracheal intubation and tube-changing catheter are being used.
📊
Key Findings & Data:In this case report, a patient with a mouth opening of 0.2 mm due to retromolar mass underwent awake fiberoptic nasotracheal intubation for biopsy.
💡
Conclusion & Impact:In this case, we present our experience with awake fiberoptic nasotracheal intubation, extubation performed with an airway exchange catheter in a patient who subsequently developed pneumothorax.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In the expected cases of difficult intubation, awake fiberoptic nasotracheal intubation and tube-changing catheter are being used. These practices can be life-saving but can also induce some complications, as well. In this case report, a patient with a mouth opening of 0.2 mm due to retromolar mass underwent awake fiberoptic nasotracheal intubation for biopsy. A tube changer catheter was used on the extubation. Pneumothorax was observed after extubation. In this case, we present our experience with awake fiberoptic nasotracheal intubation, extubation performed with an airway exchange catheter in a patient who subsequently developed pneumothorax.

Özet

Beklenen zor entubasyon olgularında uyanık fiber optik entübasyon ve tüp değiştirici kateter kullanılmaktadır. Bu uygulamalar yaşam kurtarıcı olmasının yanında bazı komplikasyonlara neden olabilir. Bu olguda, retromolar kitleye bağlı ağız açıklığı, 0,2 mm olan hastaya, biyopsi amaçlı uyanık nazal fiberoptik entubasyon yapıldı. Ekstubasyonda tüp değiştirici kateter kulanıldı. Ekstubasyon sonrası pnömotoraks gözlendi. Bu olguda, nazal uyanık fiberoptik entübasyon, tüp değiştirici kateterle yapılan ekstubasyon ve sonrasında gelişen pnömotoraks ile ilgili deneyimimizi sunduk.

🔖

Cite This Article

OKUYUCU, K. A., YURT, E., YILMAZ, M., SARAÇOĞLU, K. T., SELCUK, A. (2020). Pneumothorax Caused by Airway Extubation Catheter in a Difficult Intubation Case. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi, Cilt: 26 - Sayı: 2, 106–110. https://ajindex.com/articles/158087

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
  2. El-Boghdadly K, Onwochei DN, Cuddihy J, Ahmad I. A prospective cohort study of awake fibreoptic intubation practice at a tertiary centre. Anaesthesia 2017;72: 694-703. https://doi.org/10.1111/anae.13844 3.
  3. McLean S, Lanam CR, Benedict W, Kirkpatrick N, Kheterpal S, Ramachandran SK. Airway Exchange failure and complications with the use of the Cook Airway Exchange Catheter®: a single center cohort study of 1177 patients. Anesth Analg. 2013;117:1325-7.
  4. Supkis DE Jr, Dougherty TB, Nguyen DT, Cagle CK. Anesthetic management of the patient undergoing head and neck cancer surgery. Int Anesthesiol Clin. 1998;36:21-9.
  5. Benumof JL. Airway exchange catheters: simple concept, potentially great danger. Anesthesiology. 1999;91: 342-4.
  6. Saracoglu KT, Yilmaz M, Duzyol IY, Turan AZ, Okuyucu KA, Yurt E. Advanced techniques in extubation: Bailey maneuver, tube exchange catheter and staged extubation set. J Clin Anesth. 2018;48:28-9.
  7. Demling RH, Read T, Lind LJ, Flanagan HL: Incidence and morbiditiy of extubation failure in surgical intensive care patients. Crit Care Med. 1988;16:573-7.
  8. Ho CM, Yin IW, Tsou KF, Chow LH, Tsai SK. Gastric rupture after awake fibreoptic intubation in a patient with laryngeal carcinoma. Br J Anaesth. 2005;94:856-8.
  9. Pirlich N, Lohse JA, Noppens RR. Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow. J Vis Exp 2017 Jan 13;(119).
  10. Baraka AS. Tension pneumothorax complicating jet ventilation via a cook airway exchange catheter. Anesthesiology. 1999 Aug;91(2):557-8. https://doi.org/10.1097/00000542-199908000-00031 12. de Almeida JP, Hajjar LA, Fukushima JT, Nakamura RE, Albertini R, Galas FR. Bronchial injury and pneumothorax after reintubation using an airway exchange catheter. Braz J Anesthesiol. 2013;63:107-9.
  11. Hulst AH, Avis HJ, Hollmann MW, Stevens MF. Massive Subcutaneous Emphysema