Journals / Türk Odyoloji ve İşitme Araştırmaları Dergisi / 2026 / Cilt: 3 Sayı: 2

Vestibular function after cochlear implant surgery

Koklear implant cerrahisi sonrası vestibüler fonksiyon

Elif Tuğba Saraç(MUSTAFA KEMAL ÜNİVERSİTESİ)
Hüseyin Deniz(GAZİANTEP ÜNİVERSİTESİ, SAĞLIK BİLİMLERİ FAKÜLTESİ, ODYOLOJİ BÖLÜMÜ)
Pages
1–6
Publication Date
2020-08-29
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Vestibular evaluation in determining the CI side better guides the CI team and can reduce vestibular dysfunction which may occur after surgery.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: Aim of this study is analyzing the effects of cochlear implant (CI)surgery on vestibular function.
📊
Key Findings & Data:Results: Tracking and saccadic tests, when the participants who use cochlear implants and the control group were compared,no statistically significant difference was found between the two groups, except for right saccadic accuracy and saccadic latency parameters.
💡
Conclusion & Impact:Conclusion: Vestibular evaluation in determining the CI side better guides the CI team and can reduce vestibular dysfunction which may occur after surgery.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:koklear implantasyon · vestibüler değerlendirme · videonistagmografi

Abstract

Aim: Aim of this study is analyzing the effects of cochlear implant (CI)surgery on vestibular function. Material and Methods: CI users who had no vertigo complaints pre-op, and who experienced vestibular problems post-op were included in the case group.Healthy individuals who did not have vestibular or hearing problems were included in the control group.The users’ peripheric and central vestibular pathways were evaluated with videonystagmography (VNG). Results: Tracking and saccadic tests, when the participants who use cochlear implants and the control group were compared,no statistically significant difference was found between the two groups, except for right saccadic accuracy and saccadic latency parameters. In the CI and control groups,spontaneous and head shake nystagmus were not observed,it was determined that the two electrodes did not exert a different effect on the VNG test battery. Conclusion: Vestibular evaluation in determining the CI side better guides the CI team and can reduce vestibular dysfunction which may occur after surgery.

Özet

Amaç: Bu çalışmanın amacı koklear implant (CI) cerrahisinin vestibüler fonksiyon üzerindeki etkilerini incelemektir. Gereç ve Yöntemler: Ameliyat öncesi vertigo şikayeti olmayan ve ameliyat sonrası vestibüler problem yaşayan CI kullanıcıları vaka grubuna dahil edildi. Vestibüler veya işitme problemi olmayan sağlıklı bireyler kontrol grubuna dahil edildi. Periferik ve santral vestibüler yolaklar videonistagmografi (VNG) ile değerlendirildi. Bulgular: Tracking ve sakkadik testler, koklear implant kullanan katılımcılar ile kontrol grubu karşılaştırıldığında, sağ sakkadik doğruluk ve sakkadik latans parametreleri dışında iki grup arasında istatistiksel olarak anlamlı bir fark bulunmadı. Vaka ve kontrol gruplarında spontan ve head shake nistagmus gözlenmedi, iki elektrodun VNG test pili üzerinde farklı bir etki oluşturmadığı belirlendi. Sonuç: CI tarafının belirlenmesinde vestibüler değerlendirme, CI ekibine daha iyi rehberlik eder ve ameliyat sonrası ortaya çıkabilecek vestibüler disfonksiyonu azaltabilir

🔖

Cite This Article

Saraç, E. T., Deniz, H., Okuyucu, Ş., Akoğlu, E., Berber, Ö. (2020). Vestibular function after cochlear implant surgery. Türk Odyoloji ve İşitme Araştırmaları Dergisi, Cilt: 3 Sayı: 2, 1–6. https://ajindex.com/articles/1560857

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (36)

  1. Agrawal, Y., Pineault, K. G., & Semenov, Y. R. (2018). Health-related quality of life and economic burden of vestibular loss in older adults. Laryngoscope Investig Otolaryngol, 3(1), 8-15. doi: 10.1002/lio2.129
  2. Batuecas-Caletrio, A., Klumpp, M., Santacruz-Ruiz, S., Benito Gonzalez, F., Gonzalez Sanchez, E., & Arriaga, M. (2015). Vestibular function in cochlear implantation: Correlating objectiveness and subjectiveness. Laryngoscope, 125(10), 2371-2375. doi: 10.1002/lary.25299
  3. Colin, V., Bertholon, P., Roy, S., & Karkas, A. (2018). Impact of cochlear implantation on peripheral vestibular function in adults. Eur Ann Otorhinolaryngol Head Neck Dis, 135(6), 417-420. doi: 10.1016/j.anorl.2018.10.007
  4. Coordes, A., Ernst, A., Brademann, G., & Todt, I. (2013). Round window membrane insertion with perimodiolar cochlear implant electrodes. Otol Neurotol, 34(6), 1027-1032. doi: 10.1097/MAO.0b013e318280da2a
  5. Dagkiran, M., Tuncer, U., Surmelioglu, O., Tarkan, O., Ozdemir, S., Cetik, F., & Kiroglu, M. (2019). How does cochlear implantation affect five vestibular end-organ functions and dizziness? Auris Nasus Larynx, 46(2), 178-185. doi: 10.1016/j.anl.2018.07.004
  6. Devroede, B., Pauwels, I., Le Bon, S. D., Monstrey, J., & Mansbach, A. L. (2016). Interest of vestibular evaluation in sequentially implanted children: Preliminary results. Eur Ann Otorhinolaryngol Head Neck Dis, 133 Suppl 1, S7-s11. doi: 10.1016/j.anorl.2016.04.012
  7. Dobbels, B., Mertens, G., Gilles, A., Claes, A., Moyaert, J., van de Berg, R.,. Van Rompaey, V. (2019). Cognitive Function in Acquired Bilateral Vestibulopathy: A Cross-Sectional Study on Cognition, Hearing, and Vestibular Loss. Front Neurosci, 13, 340. doi: 10.3389/fnins.2019.00340
  8. Farinetti, A., Ben Gharbia, D., Mancini, J., Roman, S., Nicollas, R., & Triglia, J. M. (2014). Cochlear implant complications in 403 patients: comparative study of adults and children and review of the literature. Eur Ann Otorhinolaryngol Head Neck Dis, 131(3), 177-182. doi: 10.1016/j.anorl.2013.05.005
  9. Fina, M., Skinner, M., Goebel, J. A., Piccirillo, J. F., Neely, J. G., & Black, O. (2003). Vestibular dysfunction after cochlear implantation. Otol Neurotol, 24(2), 234-242; discussion 242. doi: 10.1097/00129492-200303000-00018
  10. Frodlund, J., Harder, H., Maki-Torkko, E., & Ledin, T. (2016). Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes. Otol Neurotol, 37(10), 1535-1540. doi: 10.1097/mao.0000000000001229
  11. Gnanasegaram, J. J., Parkes, W. J., Cushing, S. L., McKnight, C. L., Papsin, B. C., & Gordon, K. A. (2016). Stimulation from Cochlear Implant Electrodes Assists with Recovery from Asymmetric Perceptual Tilt: Evidence from the Subjective Visual Vertical Test. Front Integr Neurosci, 10, 32. doi: 10.3389/fnint.2016.00032 https://www.fda.gov/medical-devices. (28.08.2018). cochlear-implants/benefits-and-risks-cochlear-implants. Retrieved 29.11.2019
  12. Ibrahim, I., da Silva, S. D., Segal, B., & Zeitouni, A. (2017). Effect of cochlear implant surgery on vestibular function: meta-analysis study. J Otolaryngol Head Neck Surg, 46(1), 44. doi: 10.1186/s40463-017-0224-0
  13. Jacot, E., Van Den Abbeele, T., Debre, H. R., & Wiener-Vacher, S. R. (2009). Vestibular impairments pre- and post-cochlear implant in children. Int J Pediatr Otorhinolaryngol, 73(2), 209-217. doi: 10.1016/j.ijporl.2008.10.024
  14. Katsiari, E., Balatsouras, D. G., Sengas, J., Riga, M., Korres, G. S., & Xenelis, J. (2013). Influence of cochlear implantation on the vestibular function. Eur Arch Otorhinolaryngol, 270(2), 489-495. doi: 10.1007/s00405-012-1950-6
  15. Khan, S., & Chang, R. (2013). Anatomy of the vestibular system: a review. NeuroRehabilitation, 32(3), 437-443. doi: 10.3233/nre-130866
  16. Kluenter, H. D., Lang-Roth, R., & Guntinas-Lichius, O. (2009). Static and dynamic postural control before and after cochlear implantation in adult patients. Eur Arch Otorhinolaryngol, 266(10), 1521-1525. doi: 10.1007/s00405-009-0936-5
  17. Krause, E., Louza, J. P., Hempel, J. M., Wechtenbruch, J., Rader, T., & Gurkov, R. (2009). Effect of cochlear implantation on horizontal semicircular canal function. Eur Arch Otorhinolaryngol, 266(6), 811-817. doi: 10.1007/s00405-008-0815-5
  18. Krause, E., Louza, J. P., Wechtenbruch, J., & Gurkov, R. (2010). Influence of cochlear implantation on peripheral vestibular receptor function. Otolaryngol Head Neck Surg, 142(6), 809-813. doi: 10.1016/j.otohns.2010.01.017
  19. Kuang, H., Haversat, H. H., & Michaelides, E. M. (2015). Impairment of Caloric Function After Cochlear Implantation. J Speech Lang Hear Res, 58(4), 1387-1395. doi: 10.1044/2015_jslhr-h-15-0010
  20. Kubo, T., Yamamoto, K., Iwaki, T., Doi, K., & Tamura, M. (2001). Different forms of dizziness occurring after cochlear implant. Eur Arch Otorhinolaryngol, 258(1), 9-12. doi: 10.1007/pl00007519
  21. Lammers, M. J., van der Heijden, G. J., Pourier, V. E., & Grolman, W. (2014). Bilateral cochlear implantation in children: a systematic review and best-evidence synthesis. Laryngoscope, 124(7), 1694-1699. doi: 10.1002/lary.24582
  22. Limb, C. J., Francis, H. F., Lustig, L. R., Niparko, J. K., & Jammal, H. (2005). Benign positional vertigo after cochlear implantation. Otolaryngol Head Neck Surg, 132(5), 741-745. doi: 10.1016/j.otohns.2005.01.004
  23. Louza, J., Mertes, L., Braun, T., Gurkov, R., & Krause, E. (2015). Influence of insertion depth in cochlear implantation on vertigo symptoms and vestibular function. Am J Otolaryngol, 36(2), 254-258. doi: 10.1016/j.amjoto.2014.11.007
  24. Melvin, T. A., Della Santina, C. C., Carey, J. P., & Migliaccio, A. A. (2009). The effects of cochlear implantation on vestibular function. Otol Neurotol, 30(1), 87-94. doi: 10.1097/mao.0b013e31818d1cba
  25. Nguyen, S., Cloutier, F., Philippon, D., Cote, M., Bussieres, R., & Backous, D. D. (2016). Outcomes review of modern hearing preservation technique in cochlear implant. Auris Nasus Larynx, 43(5), 485-488. doi: 10.1016/j.anl.2016.02.014
  26. Nguyen, T. A., DiGiovanna, J., Cavuscens, S., Ranieri, M., Guinand, N., van de Berg, R.,. Fornos, A. P. (2016). Characterization of pulse amplitude and pulse rate modulation for a human vestibular implant during acute electrical stimulation. J Neural Eng, 13(4), 046023. doi: 10.1088/1741-2560/13/4/046023
  27. Perez-Martin, J., Artaso, M. A., & Diez, F. J. (2017). Cost-effectiveness of pediatric bilateral cochlear implantation in Spain. Laryngoscope, 127(12), 2866-2872. doi: 10.1002/lary.26765
  28. Shoman, N., Ngo, R., Archibald, J., Pijl, S., Chan, S., & Westerberg, B. D. (2008). Prevalence of new-onset vestibular symptoms following cochlear implantation. J Otolaryngol Head Neck Surg, 37(3), 388-394.
  29. Sorkin, D. L. (2013). Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States. Cochlear Implants Int, 14 Suppl 1, S4-12. doi: 10.1179/1467010013z.00000000076
  30. Sosna, M., Tacikowska, G., Pietrasik, K., Skarzynski, H., Lorens, A., & Skarzynski, P. H. (2019). Effect on vestibular function of cochlear implantation by partial deafness treatment-electro acoustic stimulation (PDT-EAS). Eur Arch Otorhinolaryngol, 276(7), 1951-1959. doi: 10.1007/s00405-019-05425-5
  31. Tien, H. C., & Linthicum, F. H., Jr. (2002). Histopathologic changes in the vestibule after cochlear implantation. Otolaryngol Head Neck Surg, 127(4), 260-264. doi: 10.1067/mhn.2002.128555
  32. Todt, I., Basta, D., & Ernst, A. (2008). Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo? Otolaryngol Head Neck Surg, 138(1), 8-12. doi: 10.1016/j.otohns.2007.09.003
  33. Tsukada, K., Moteki, H., Fukuoka, H., Iwasaki, S., & Usami, S. (2013). Effects of EAS cochlear implantation surgery on vestibular function. Acta Otolaryngol, 133(11), 1128-1132. doi: 10.3109/00016489.2013.824110
  34. Yong, M., Young, E., Lea, J., Foggin, H., Zaia, E., Kozak, F. K., & Westerberg, B. D. (2019). Subjective and objective vestibular changes that occur following paediatric cochlear implantation: systematic review and meta-analysis. J Otolaryngol Head Neck Surg, 48(1), 22. doi: 10.1186/s40463-019-0341-z
  35. Dobbels, B., Mertens, G., Gilles, A., Claes, A., Moyaert, J., van de Berg, R.,. Van Rompaey, V. (2019). Cognitive Function in Acquired Bilateral Vestibulopathy: A Cross-Sectional Study on Cognition, Hearing, and Vestibular Loss. Front Neurosci, 13, 340. doi: 10.3389/fnins.2019.00340
  36. Nguyen, T. A., DiGiovanna, J., Cavuscens, S., Ranieri, M., Guinand, N., van de Berg, R.,. Fornos, A. P. (2016). Characterization of pulse amplitude and pulse rate modulation for a human vestibular implant during acute electrical stimulation. J Neural Eng, 13(4), 046023. doi: 10.1088/1741-2560/13/4/046023