Journals / BEYOGLU EYE JOURNAL / 2019 / Cilt: 4 - Sayı: 2

Ciliary Sulcus Implantation of Ahmed Glaucoma Valve in Patients with Corneal Decompensation Risk

Pages
115–119
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This technique may be a good choice in patients with a corneal decompensation risk due to the posterior chamber implantation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The goal of this study was to examine the safety and efficacy of ciliary sulcus implantation of the Ahmed glaucoma valve (AGV; New World Medical, Inc., Rancho Cucamonga, CA, USA) in patients with a risk of corneal decom-pensation.
📊
Key Findings & Data:The success criteria were defined as a postoperative IOP of 5 to 21 mmHg and no loss of light perception.
💡
Conclusion & Impact:This technique may be a good choice in patients with a corneal decompensation risk due to the posterior chamber implantation.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objectives: The goal of this study was to examine the safety and efficacy of ciliary sulcus implantation of the Ahmed glaucoma valve (AGV; New World Medical, Inc., Rancho Cucamonga, CA, USA) in patients with a risk of corneal decom-pensation. Methods: Patients with a corneal decompensation risk who underwent AGV implantation at a single institution were included in this retrospective study. The patients’ preoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), and the number of anti-glaucomatous eye drop medications used was compared with postoperative values. The success criteria were defined as a postoperative IOP of 5 to 21 mmHg and no loss of light perception. Results: Twenty-three eyes of 23 (16 male, 7 female) patients were included in the study. The mean age of the patients was 64.6±14.6 years and the mean follow-up period was 15.8±8.3 months. The preoperative mean IOP was reduced from 33.6±9.1 mmHg to 16.9±5.1 mmHg at the last follow-up (p=0.000). The mean preoperative number of anti-glaucomatous eye drop medications used was 3.5±1.3. Postoperatively the mean was 1.7±1.4 at the last follow-up (p=0.000). The rate of total success was determined to be 78%. The postoperative mean BCVA did not change significantly. One patient lost light perception. A decrease in corneal clarity was observed in only 1 patient (4.3%). The postoperative complications observed were: bleb encapsulation (43%), hyphema (39%), tube occlusion (13%), choroidal detachment (8.7%), decom-pression retinopathy (8.7%), and corneal decompensation (4.3%). Conclusion: Ciliary sulcus implantation of an AGV was effective, both in terms of IOP and the decrease in anti-glauco-matous drug use in the short term. This technique may be a good choice in patients with a corneal decompensation risk due to the posterior chamber implantation.

🔖

Cite This Article

İMAMOĞLU, S., ERÇALIK, N. Y., BEŞER, B. G., ÇELİK, N. B. (2019). Ciliary Sulcus Implantation of Ahmed Glaucoma Valve in Patients with Corneal Decompensation Risk. BEYOGLU EYE JOURNAL, Cilt: 4 - Sayı: 2, 115–119. https://ajindex.com/articles/144276

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Şatana B, Yalvaç I, Kasım R, Duman S. İleri glokom olguların-da Molteno tüp ve Ahmed glokom valv implantının klinik sonuçlarının değerlendirilmesi. T Oft Gaz 2002;32:100–6.
  2. Coleman AL, Hill R, Wilson MR, Choplin N, Kotas-Neumann R, Tam M, et al. Initial clinical experience with the Ahmed Glau-coma Valve implant. Am J Ophthalmol 1995;120:23–31.
  3. Huh KC, Kee CW. A clinical analysis of the Ahmed glaucoma valve implant with or without partial ligation of silicone tube. J Korean Ophthalmol Soc 2000;41:2611–7.
  4. Sidoti PA, Mosny AY, Ritterband DC, Seedor JA. Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. Ophthalmology 2001;108:1050–8.
  5. Kwon YH, Taylor JM, Hong S, Honkanen RA, Zimmerman MB, Alward WL, et al. Long-term results of eyes with penetrating keratoplasty and glaucoma drainage tubeimplant. Ophthalmol-ogy 2001;108:272–8.
  6. Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, et al. Follow-up of the original cohort with the Ahmed glauco-ma valve implant. Am J Ophthalmol 1999;128:198–204.
  7. Kook MS, Yoon J, Kim J, Lee MS. Clinical results of Ahmed glau-coma valve implantation in refractory glaucoma with adjunctive mitomycin C. Ophthalmic Surg Lasers 2000;31:100–6.
  8. Wilson MR, Mendis U, Paliwal A, Haynatzka V. Long-term follow-up of primary glaucoma surgery with Ahmed glauco-ma valve implant versus trabeculectomy. Am J Ophthalmol 2003;136:464–70.
  9. Gedde SJ, Herndon LW, Brandt JD, Budenz DL, Feuer WJ, Schiffman JC. Surgical complications in the Tube Versus Trabe-culectomy Study during the first year of follow-up. Am J Oph-thalmol 2007;143:23–31.
  10. Bayer A, Önol M. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus. Eye (Lond) 2017;31:608–14.
  11. Weiner A, Cohn AD, Balasubramaniam M, Weiner AJ. Glau-coma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation. J Glaucoma 2010;19:405–11.
  12. Lee EK, Yun YJ, Lee JE, Yim JH, Kim CS. Changes in corneal en-dothelial cells after Ahmed glaucoma valve implantation: 2-year follow-up. Am J Ophthalmol 2009;148:361–7.
  13. Eslami Y, Mohammadi M, Fakhraie G, Zarei R, Moghimi S. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes. J Glau-coma 2014;23:115–8.
  14. Souza C, Tran DH, Loman J, Law SK, Coleman AL, Caprioli J. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Op