Journals / International Journal of Thermodynamics / 2026 / Volume: 13 Issue: 3

Conventional Exergetic and Exergoeconomic Analyses of a Power Plant with Chemical Looping Combustion for CO2 Capture

Pages
—
Publication Date
2010-02-25
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, due to the addition of the CO 2 compression unit, the overall exergetic efficiency of the plant with CLC is lower than that of the reference plant by approximately 5 percentage points.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Normal 0 21 MicrosoftInternetExplorer4 Exergy-based methods can be used as a tool for examining, comparing and assessing thermodynamic systems.
📊
Key Findings & Data:In this paper, an exergoeconomic analysis is used to evaluate a power plant with chemical looping combustion (CLC) for CO 2 capture.
💡
Conclusion & Impact:However, due to the addition of the CO 2 compression unit, the overall exergetic efficiency of the plant with CLC is lower than that of the reference plant by approximately 5 percentage points.
🔬Design:Article
📍Scope:Comprehensive Sample
⚙️Variables:CO2 capture · chemical looping combustion · exergetic analysis

Abstract

Normal 0 21 MicrosoftInternetExplorer4 Exergy-based methods can be used as a tool for examining, comparing and assessing thermodynamic systems. In this paper, an exergoeconomic analysis is used to evaluate a power plant with chemical looping combustion (CLC) for CO 2 capture. This oxy-fuel plant is compared, from an exergetic and an economic perspective, to a conventional, reference power plant without CO 2 capture. The exergetic analysis shows decreased exergy destruction in the CLC reactors, compared to the exergy destruction in the conventional combustion chamber of the reference case; thus, the irreversibilities caused by combustion in the CLC are reduced. However, due to the addition of the CO 2 compression unit, the overall exergetic efficiency of the plant with CLC is lower than that of the reference plant by approximately 5 percentage points. The economic analysis confirms a significant increase in the investment cost of the CO 2 capture plant, due to the addition of the units for CO 2 compression and CLC. Thus, the cost of electricity is 24% higher for this plant in comparison to that of the reference case. Nevertheless, when compared to the reference plant with CO 2 capture with monoethanolamine, the plant with CLC was found to be a more economical option. Since CO 2 abatement must be realized in the future, given expected environmental or tax measures, CLC provides relatively low cost carbon dioxide capture and it, therefore, appears to be a promising option for reducing greenhouse gases emitted by power plants using fossil fuels.

🔖

Cite This Article

Petrakopoulou, F., Tsatsaronis, G., Morosuk, T. (2010). Conventional Exergetic and Exergoeconomic Analyses of a Power Plant with Chemical Looping Combustion for CO2 Capture. International Journal of Thermodynamics, Volume: 13 Issue: 3. https://ajindex.com/articles/1415244

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...