Journals / Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2021 / Cilt: 14 Sayı: 3

Comparison of the Effective Atomic Numbers of Some Contrast Agents Compounds Used in Medical Imaging

Yusuf Kavun(KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNİVERSİTESİ, KAHRAMANMARAŞ SAĞLIK HİZMETLERİ MESLEK YÜKSEKOKULU)0000-0001-9635-4388
Pages
1055–1065
Publication Date
2021-12-18
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to these results, it was seen that the results were compatible with each other in low energy regions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Contrast agents are frequently used in medical imaging such as computed tomography (CT) and magnetic resonance (MR) to reveal the final state of the body or organs.
📊
Key Findings & Data:In this study, C17H22I3N3O8 (Iopamidol), C11H9I3N2O4 (Diatrizoic acid), BaSO4 (Barium sulfate) and C7H6O2 (Benzoic acid) compounds are examined to calculate effective atomic number (Zeff).
💡
Conclusion & Impact:According to these results, it was seen that the results were compatible with each other in low energy regions.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Iopamidol · Diatrizoic Acid · Barium Sulfate

Abstract

Contrast agents are frequently used in medical imaging such as computed tomography (CT) and magnetic resonance (MR) to reveal the final state of the body or organs. The states of the organs examined are obtained according to the absorption principle of x or gamma rays interacting with contrast agents. In this study, C17H22I3N3O8 (Iopamidol), C11H9I3N2O4 (Diatrizoic acid), BaSO4 (Barium sulfate) and C7H6O2 (Benzoic acid) compounds are examined to calculate effective atomic number (Zeff). Auto-Zeff and Direc-Zeff software have been used for calculation in an energy range from 100 keV to 10 MeV. According to the calculation results obtained have been compared with each other for each compound. According to these results, it was seen that the results were compatible with each other in low energy regions.

🔖

Cite This Article

Kavun, Y., *, Y. K. (2021). Comparison of the Effective Atomic Numbers of Some Contrast Agents Compounds Used in Medical Imaging. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 14 Sayı: 3, 1055–1065. https://doi.org/10.18185/erzifbed.912373

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Çakır, T., 2020. Determining the photon interaction parameters of iodine compounds as contrast agents for use in radiology. J. Radiat. Res. Appl. Sci. https://doi.org/10.1080/16878507.2020.1731065
  2. Krause Werner, 2002. Contrast Agents I, Springer. ed, Topics in Current Chemistry. Springer Berlin Heidelberg, Berlin, Heidelberg. https://doi.org/10.1007/3-540-45733-X
  3. Kurudirek, M., 2014. Radiation shielding and effective atomic number studies in different types of shielding concretes, lead base and non-lead base glass systems for total electron interaction: A comparative study. Nucl. Eng. Des. 280, 440–448. https://doi.org/10.1016/j.nucengdes.2014.09.020
  4. Neutze, J.A., 2020. Introduction to radiology concepts, in: Radiology Fundamentals: Introduction to Imaging & Technology. Springer International Publishing. https://doi.org/10.1007/978-3-030-22173-7_3
  5. Özpolat, Ö.F., Alım, · B, Şakar, · E, Büyükyıldız, · M, Kurudirek, · M, 2020. Phy-X/ZeXTRa: a software for robust calculation of effective atomic numbers for photon, electron, proton, alpha particle, and carbon ion interactions. Radiat. Environ. Biophys. 59, 321–329. https://doi.org/10.1007/s00411-019-00829-7
  6. Sayyed, M.I., 2016. Investigation of shielding parameters for smart polymers. Chinese J. Phys. 54, 408–415. https://doi.org/10.1016/j.cjph.2016.05.002
  7. Sayyed, M.I., El-Mesady, I.A., Abouhaswa, A.S., Askin, A., Rammah, Y.S., 2019. Comprehensive study on the structural, optical, physical and gamma photon shielding features of B2O3-Bi2O3-PbO-TiO2 glasses using WinXCOM and Geant4 code. J. Mol. Struct. 1197, 656–665. https://doi.org/10.1016/j.molstruc.2019.07.100
  8. Singh, H., Neutze, J.A., 2012. Nuclear Medicine, in: Radiology Fundamentals. Springer New York, New York, NY, pp. 31–34. https://doi.org/10.1007/978-1-4614-0944-1_7
  9. Taylor, M.L., Smith, R.L., Dossing, F., Franich, R.D., 2012. Robust calculation of effective atomic numbers: The Auto-Zeff software. Med. Phys. 39, 1769–1778. https://doi.org/10.1118/1.3689810
  10. Thomsen, H.S., Bellin, M.-F., Jakobsen, J.Å., Webb, J.A.W., 2014. Contrast Media Classification and Terminology. pp. 3–11. https://doi.org/10.1007/174_2013_864
  11. Un, A., Caner, T., 2014. The Direct-Zeff software for direct calculation of mass attenuation coefficient, effective atomic number and effective electron number. Ann. Nucl. Energy. https://doi.org/10.1016/j.anucene.2013.10.041
  12. William Herring, 2019. Learning Radiology - 4th Edition, 1st ed. elsevier.