Journals / Osmaniye Korkut Ata Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2026 / Cilt: 5 Sayı: 2

Theoretical Investigation of Some Radiation Shielding Parameters of Radiodiagnostic Agents

Bazı Radyodiagnostik Ajanların Radyasyon Koruyucu Parametrelerinin Teorik İncelenmesi

Yusuf Kavun(KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNİVERSİTESİ, KAHRAMANMARAŞ SAĞLIK HİZMETLERİ MESLEK YÜKSEKOKULU)0000-0001-9635-4388
Eyyup Tel(OSMANIYE KORKUT ATA UNIVERSITY)
Pages
829–839
Publication Date
2022-07-18
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to the data obtained, it was seen that the data scattered up to 100 keV were compatible with each other after this energy value.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The impact of medical imaging in health services is increasing day by day.
📊
Key Findings & Data:As the use of medical imaging goes beyond diagnosis and reaches the areas of disease prevention and treatment, the costs of healthcare services on a global scale are also significantly reduced.
💡
Conclusion & Impact:According to the data obtained, it was seen that the data scattered up to 100 keV were compatible with each other after this energy value.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Phy-X yazılımı · Radyasyon zırhlama · Gadoxetic asit

Abstract

The impact of medical imaging in health services is increasing day by day. In this way, diseases can be diagnosed earlier and treatments can be carried out more effectively. As the use of medical imaging goes beyond diagnosis and reaches the areas of disease prevention and treatment, the costs of healthcare services on a global scale are also significantly reduced. In this study, radiation shielding properties of drugs such as C23H30GdN3O11 (Gadoxetic acid), C28H54GdN5O20 (Gadopentetic acid) and C20H12O5 (Fluorescein) used in imaging have been investigated. These radiation parameters include linear and mass attenuation coefficients (LAC, MAC), half and tenth value layers (HVL, TVL), mean free path (MFP), effective atomic number and electron density (Zeff, Neff) and effective conductivity (Ceff) energy by using Phy-X software. These data have been generated for 1 keV to 2 MeV energy region. According to the data obtained, it was seen that the data scattered up to 100 keV were compatible with each other after this energy value.

Özet

Tıbbi görüntülemenin sağlık hizmetlerindeki etkisi her geçen gün artmaktadır. Bu sayede hastalıklar daha erken teşhis edilebilir ve tedaviler daha etkin bir şekilde yürütülebilir. Tıbbi görüntülemenin kullanımı teşhisin ötesine geçerek hastalık önleme ve tedavi alanlarına ulaştığından, küresel ölçekte sağlık hizmetlerinin maliyetleri de önemli ölçüde azalmaktadır. Bu çalışmada, görüntülemede kullanılan C23H30GdN3O11 (Gadoxetic asit), C28H54GdN5O20 (Gadopentetik asit) ve C20H12O5 (Fluorescein) gibi ilaçların radyasyon koruyucu özellikleri araştırılmıştır. Bu radyasyon parametreleri, lineer ve kütle zayıflama katsayılarını (LAC, MAC), yarım ve onuncu değer katmanlarını (HVL, TVL), ortalama serbest yolu (MFP), etkin atom numarası ve elektron yoğunluğunu (Zeff, Neff) ve etkin iletkenliği (Ceff) içerir. Phy-X yazılımını kullanarak enerji. Bu veriler 1 keV ile 2 MeV enerji bölgesi aralığı için üretilmiştir. Elde edilen verilere göre bu enerji değerinden sonra 100 keV'a kadar saçılan verilerin birbiriyle uyumlu olduğu görülmüştür.

🔖

Cite This Article

Kavun, Y., Tel, E. (2022). Theoretical Investigation of Some Radiation Shielding Parameters of Radiodiagnostic Agents. Osmaniye Korkut Ata Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 5 Sayı: 2, 829–839. https://doi.org/10.47495/okufbed.992797

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (22)

  1. Abbott Northwestern Hospital, 2009. MRI SHIELDING ARCHITECTURAL SITE PLANNING GUIDE. ETS-Lindgren 307–7571.
  2. Agar, O., 2018. Study on gamma ray shielding performance of concretes doped with natural sepiolite mineral. Radiochim. Acta. https://doi.org/10.1515/ract-2018-2981
  3. Bisgard-Frantzen, H., Svendsen, A., 2000. (30) Foreign Application Priority Data.
  4. Bormann, R.L., Rocha, E.L. da, Kierzenbaum, M.L., Pedrassa, B.C., Torres, L.R., D’Ippolito, G., 2015. The role of gadoxetic acid as a paramagnetic contrast medium in thecharacterization and detection of focal liver lesions: a review. Radiol. Bras. 48, 43. https://doi.org/10.1590/0100-3984.2013.1794
  5. Duvall, B., Kershner, R.M., 2006. Ophthalmic medications and pharmacology 130.
  6. Gessner, T., 2000. “Triarylmethane and Diarylmethane Dyes,” in: Ullmann’s Encyclopedia of Industrial Chemistry. Ullmann’s Encycl. Ind. Chem. https://doi.org/10.1002/14356007.a27_179
  7. H. Eskalen, Y. Kavun, S. Kerli, S. Eken, 2020. An investigation of radiation shielding properties of boron doped ZnO thin films. Opt. Mater. (Amst). 105. https://doi.org/10.1016/j.optmat.2020.109871
  8. James E. Martin and Tanır G, 2013. Radyasyon ve radyasyondan korunma fiziği: sağlık fiziği uygulamalı, 2020th ed. Palme Yayıncılık.
  9. Kadıyoran C., 2010. Gastrointestinal Maligniteli Hastalarda Karaciğer Metastazlarının Manyetik Rezonans İle Saptanmasında Gadoksetik Asit Ve Gadopentate Dđmegluminin Etkinliğinin Karsılastırılması. SELÇUK ÜNİVERSİTESİ MERAM TIP FAKÜLTESİ.
  10. Kavun, Y., Eskalen, H., Kerli̇, S., Kavgaci, M., 2021. Fabrication and characterization of GdxFe2O3(100-x) /PVA (x=0, 5, 10, 20) composite films for radiation shielding. Appl. Radiat. Isot. 177, 109918. https://doi.org/10.1016/J.APRADISO.2021.109918
  11. Kavun, Y., TEL, E., ŞAHAN, M., SALAN, A., 2019a. Nükleer Tıpta Kullanılan Bazı Radyofarmasötiklerin Üretim Reaksiyon Tesir Kesitlerinin Yoğunluğa Bağlı Yeni Parametrelerle Hesaplanması. Süleyman Demirel Üniversitesi Fen Edeb. Fakültesi Fen Derg. 57–61. https://doi.org/10.29233/sdufeffd.477539
  12. Kavun, Y., Uruş, S., Tutuş, A., Eken, S., Özbek, R., 2019b. Investigation of Radiation Absorption Properties of Tungstate and Molibdate Doped Wallpapers. Cumhur. Sci. J. 40, 846–853. https://doi.org/10.17776/csj.600967
  13. Knoll, G.F., Kraner, H.W., 1981. Radiation Detection and Measurement. Proc. IEEE. https://doi.org/10.1109/PROC.1981.12016
  14. Krane, K.S., Lynch, W.G., 1989. Introductory Nuclear Physics. Phys. Today. https://doi.org/10.1063/1.2810884
  15. Murphy1, K.J., Brunberg, J.A., Cohan1, R.H., 1996. Adverse Reactions to Gadolinium Contrast Media: A Review of 36 Cases. AJR 167.
  16. Şakar, E., Özpolat, Ö.F., Alım, B., Sayyed, M.I., Kurudirek, M., 2020. Phy-X / PSD: Development of a user friendly online software for calculation of parameters relevant to radiation shielding and dosimetry. Radiat. Phys. Chem. 166, 108496. https://doi.org/10.1016/J.RADPHYSCHEM.2019.108496
  17. Seunghoon, H., MJ, H., WW, R., LT, M., O, N., 2010. Development of a new RF coil and gamma-ray radiation shielding assembly for improved MR image quality in SPECT/MRI. Phys. Med. Biol. 55, 2495–2504. https://doi.org/10.1088/0031-9155/55/9/005
  18. Sim, S., Jeon, D., Kim, D.H., Yum, W. sung, Yoon, S., Oh, J.E., 2021. Incorporation of copper slag in cement brick production as a radiation shielding material. Appl. Radiat. Isot. 176, 109851. https://doi.org/10.1016/J.APRADISO.2021.109851
  19. Un, A., Caner, T., 2014. The Direct-Zeff software for direct calculation of mass attenuation coefficient, effective atomic number and effective electron number. Ann. Nucl. Energy. https://doi.org/10.1016/j.anucene.2013.10.041
  20. Weibler, J., 1993. Properties of metals used for RF shielding. EMC Test Des.
  21. James E. Martin and Tanır G, 2013. Radyasyon ve radyasyondan korunma fiziği: sağlık fiziği uygulamalı, 2020th ed. Palme Yayıncılık.
  22. Krane, K.S., Lynch, W.G., 1989. Introductory Nuclear Physics. Phys. Today. https://doi.org/10.1063/1.2810884