Journals / Hacettepe Journal of Biology and Chemistry / 2023 / Cilt: 51 Sayı: 4

E. coli O157:H7 Detection Using Surface Plasmon Resonance Based Biosensor

Pages
359–372
Publication Date
2023-11-07
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results suggest that the SPR based biosensor is a promising tool for the rapid detection of foodborne pathogens in complex food matrices.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The detection of foodborne pathogenic bacteria remains a significant challenge, and the need for fast and sensitive detection methods is becoming increasingly important.
📊
Key Findings & Data:Escherichia coli is a prevalent bacteria associated with foodborne illness, and this study aimed to evaluate the ability of a surface plasmon resonance (SPR) based biosensor to detect E. coli O157:H7 at low levels in pure culture and artificially contaminated bay leaves (Laurus nobilis) using different injection methods.
💡
Conclusion & Impact:The results suggest that the SPR based biosensor is a promising tool for the rapid detection of foodborne pathogens in complex food matrices.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:E.coli O157:H7 · SPR based biosensors · Bacterial detection

Abstract

The detection of foodborne pathogenic bacteria remains a significant challenge, and the need for fast and sensitive detection methods is becoming increasingly important. Escherichia coli is a prevalent bacteria associated with foodborne illness, and this study aimed to evaluate the ability of a surface plasmon resonance (SPR) based biosensor to detect E. coli O157:H7 at low levels in pure culture and artificially contaminated bay leaves (Laurus nobilis) using different injection methods. To develop a biological sensing surface, the sensor surface was functionalized with 3-aminopropyltriethoxysilane (APTES), and polyclonal antibodies were immobilized on the surface for bacteria detection. Bacterial attachment to the antibodies resulted in a change in resonance angle. The biosensor was able to discriminate between cellular concentrations of 103 to 107 CFU/mL and showed potential in detecting different pathogens in various food samples. Before the SPR detection, the sample preparation step was optimized to ensure complex food matrices were suitable for SPR analysis. The results suggest that the SPR based biosensor is a promising tool for the rapid detection of foodborne pathogens in complex food matrices.

🔖

Cite This Article

ESER, E., EKİZ, O. Ö., EKİZ, H. İ. (2023). E. coli O157:H7 Detection Using Surface Plasmon Resonance Based Biosensor. Hacettepe Journal of Biology and Chemistry, Cilt: 51 Sayı: 4, 359–372. https://ajindex.com/articles/1016044

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. J.B. Kaper, J.P. Nataro, H.L.T. Mobley, Pathogenic Escherichia coli, Nature Reviews Microbiology, 2 (2004) 123-140.
  2. J.Y. Lim, J. Yoon, C.J. Hovde, A brief overview of Escherichia coli O157:H7 and its plasmid O157, Journal of microbiology and biotechnology, 20 (2010) 5-14.
  3. I.H. Cho, S. Ku, Current Technical Approaches for the Early Detection of Foodborne Pathogens: Challenges and Opportunities, Int J Mol Sci, 18 (2017).
  4. M. Nemati, A. Hamidi, S. Maleki Dizaj, V. Javaherzadeh, F. Lotfipour, An Overview on Novel Microbial Determination Methods in Pharmaceutical and Food Quality Control, Adv Pharm Bull, 6 (2016) 301-308.
  5. V. Velusamy, K. Arshak, O. Korostynska, K. Oliwa, C. Adley, An overview of foodborne pathogen detection: In the perspective of biosensors, Biotechnology Advances, 28 (2010) 232-254.
  6. A.H. Havelaar, S. Brul, A. de Jong, R. de Jonge, M.H. Zwietering, B.H. ter Kuile, Future challenges to microbial food safety, International Journal of Food Microbiology, 139 (2010) S79-S94. P. Leonard, S. Hearty, J. Brennan, L. Dunne, J. Quinn, T. Chakraborty, R. O’Kennedy, Advances in biosensors for detection of pathogens in food and water, Enzyme and Microbial Technology, 32 (2003) 3-13.
  7. Y. Zeng, R. Hu, L. Wang, D. Gu, J. He, S.-Y. Wu, H.-P. Ho, X. Li, J. Qu, Z. Gao Bruce, Y. Shao, Recent advances in surface plasmon resonance imaging: detection speed, sensitivity, and portability, Nanophotonics, 2017, pp. 1017. J. Kim, J.-H. Jin, H.S. Kim, W. Song, S.-K. Shin, H. Yi, D.-H. Jang, S. Shin, B.Y. Lee, Fully Automated Field-Deployable Bioaerosol Monitoring System Using Carbon Nanotube-Based Biosensors, Environmental Science & Technology, 50 (2016) 5163-5171.
  8. H.H. Nguyen, J. Park, S. Kang, M. Kim, Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications, Sensors (Basel, Switzerland), 15 (2015) 10481-10510.
  9. J. Homola, J. Ctyroky, M. Skalsky, J. Hradilova, P. Kolarova, A surface plasmon resonance based integrated optical sensor, Sensors and Actuators B-Chemical, 39 (1997) 286-290.
  10. Z. Bai, X. Xu, C. Wang, T. Wang, C. Sun, S. Liu, D. Li, A comprehensive review of detection methods for Escherichia coli O157:H7, TrAC Trends in Analytical Chemistry, 152 (2022) 116646. S. Akgönüllü, A. Denizli, Recent advances in optical biosensing approaches for biomarkers detection, Biosensors and Bioelectronics: X, 12 (2022) 100269. A. Philip, A.R. Kumar, The performance enhancement of surface plasmon resonance optical sensors using nanomaterials: A review, Coordination Ch