Dergiler / International Journal of Computational and Experimental Science and Engineering / 2023 / Cilt: 9 Sayı: 3

Method Validation and Measurement Uncertainty for the Determination of Ethanol in Whole Blood

Sayfa
253–257
Yayın Tarihi
2023-09-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The method provides fast, precise, simple, robust and unbiased results.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Alcohol intake is known to significantly affect driving ability and there is a relationship between Blood Alcohol Concentration (BAC) and the risk of road traffic accidents car accidents.
📊
Temel Bulgular & Veri:Alcohol intake is known to significantly affect driving ability.
💡
Sonuç & Katkı:The method provides fast, precise, simple, robust and unbiased results.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Whole Blood · Ethanol · HS-GC/FID

Abstract

Alcohol intake is known to significantly affect driving ability and there is a relationship between Blood Alcohol Concentration (BAC) and the risk of road traffic accidents car accidents. Alcohol intake is known to significantly affect driving ability. Therefore, many countries define and monitor the legal BAC value for drivers. Customers or legal authorities require determining and reporting the measurement uncertainty in blood alcohol analysis from laboratories in recent years. In order to ensure the reliability and safety of the result, the method was validated and the measurement uncertainty was calculated. A rapid, selective and robust gas chromatography coupled with flame ionisation detection method was developed and validated for the quantitative determination of ethanol in whole blood. The method was validated for selectivity, matrix effect, recovery, and linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, repeatability, reproducibility and robustness. The validation procedure was designed to be suitable for ISO 17025 accreditation. Uncertainty measurements were also determined for the validated method. LOD and LOQ were found 3.99 mg/dL and 4.30 mg/dL, respectively. The method showed good linearity in the range of 3.9 to 393.7 mg/dL ethanol with a correlation coefficient (r2 = 0.9999). The method provides fast, precise, simple, robust and unbiased results.

🔖

Bu Makaleye Atıf Yap

ÖZTÜRK, Y. E. (2023). Method Validation and Measurement Uncertainty for the Determination of Ethanol in Whole Blood. International Journal of Computational and Experimental Science and Engineering, Cilt: 9 Sayı: 3, 253–257. https://ajindex.com/articles/964276

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Kugelberg FC, Jones AW. (2007). Interpreting results of ethanol analysis in postmortem specimens: a review of the literature. Forensic Sci Int. 165(1):10-29. doi: 10.1016/j.forsciint.2006.05.004
  2. Sjögren H, Eriksson A, Ahlm K. (2000) Role of alcohol in unnatural deaths: a study of all deaths in Sweden. Alcohol Clin Exp Res. doi:10.1111/j.1530-0277.2000.tb04649.x
  3. NHTSA (National Highway Traffic Safety Administration), (2023, August 1). Alcohol- and Drug-Impaired Driving
  4. WHO (World Health Organization), (2023, August 1). Global status report on alcohol and health, 2018
  5. Fernie G, Christiansen P, Cole JC, Rose AK, Field M. (2012). Effects of 0.4 g/kg alcohol on attentional bias and alcohol-seeking behaviour in heavy and moderate social drinkers. J Psychopharmacol. 26(7):1017-25. doi: 10.1177/0269881111434621
  6. Tiscione NB, Alford I, Yeatman DT, Shan X. (2011). Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection. J Anal Toxicol. 35(7):501-11. doi: 10.1093/anatox/35.7.501. PMID: 21871160
  7. Jones AW. (2000) Medicolegal alcohol determinations – breath- or blood alcohol concentrations?. Forensic Sci. Rev. 12:23–47. [8]Traffic Law and Road Traffic Regulation No:6047, (2023, August 1). Regulation Number:6047
  8. Chun HJ, Poklis JL, Poklis A,Wolf CE. (2016). Development and validation of a method for alcohol analysis in brain tissue by headspace gas chromatography with flame ionization detector. Journal of Analytical Toxicology. 40: 653–658. doi: 10.1093/jat/bkw075
  9. Snow NH, Slack GC. (2002). Head-space analysis in modern gas chromatography. Trends in Analytical Chemistry. 21(9–10): 608–617. doi: 10.1016/S0165-9936(02)00802-6
  10. Nikelly JG, Betz JM (1987). Determination of ethanol in alcoholic beverages by liquid chromatography using the UV detector. Journal of Chromatographic Science. 25(9):391–394.
  11. Yarita T, Nakajima R, Otsuka S, Ihara T, Takatsu A, Shibukawa M. (2002). Determination of ethanol in alcoholic beverages by high- performance liquid chromatography flame ionization detection using pure water as mobile phase. J Chromatogr AJ Chromatogr A. 976(1-2): 387–391. doi: 10.1016/S0021-9673(02)00942-1
  12. Lachenm