Dergiler / Journal of Scientific Reports-A / 2023 / Sayı: 052

A KINETIC STUDY OF THERMOCHEMICALLY BORIDED AISI 316L STAINLESS STEEL

Sayfa
279–296
Yayın Tarihi
2023-03-29
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It was also found that surface hardness values of borided materials increased depending on temperature and time of boriding process; surface hardness values of borided materials are approximately 10 times higher than surface hardness values of non-borided AISI316L stainless steel and formation activation energy of boride layer is 149.3 kjmol-1.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Biomaterials are used in different parts of human body as replacement implants in medical applications.
📊
Temel Bulgular & Veri:There are only a few biocompatible implant materials: AISI316L stainless steel is one of the materials used in this type of applications.
💡
Sonuç & Katkı:It was also found that surface hardness values of borided materials increased depending on temperature and time of boriding process; surface hardness values of borided materials are approximately 10 times higher than surface hardness values of non-borided AISI316L stainless steel and formation activation energy of boride layer is 149.3 kjmol-1.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Boriding · AISI 316L Stainless Steel · Diffusion Kinetics

Abstract

Biomaterials are used in different parts of human body as replacement implants in medical applications. An implant material should have high biocompatibility, corrosion and wear resistance, and suitable mechanical properties in terms of safety and long-service period. There are only a few biocompatible implant materials: AISI316L stainless steel is one of the materials used in this type of applications. They have relatively poor wear resistance. Boriding being a thermochemical diffusion treatment is one of the processes to improve their wear resistance. Borides are formed by introducing boron atoms by diffusion onto a substrate surface and they are non-oxide ceramics and could be very brittle. The growth kinetics of boride layer is analyzed by measuring depth of layers as a function of boriding time within a temperature range. In this study, the effects of Ekabor-2 bath on formation mechanism and properties of boride layer in thermochemical diffusion boriding of AISI316L stainless steel were investigated. Different temperatures and durations were applied in boriding operations and hardness, optical microscopy, XRD, EPMA and SEM studies were performed to detect the properties of boride layers. It was found that thickness of boride layer increased with increasing temperature and time; the basic phase in the boride layer formed was Fe2B and FeB phase also formed. It was also found that surface hardness values of borided materials increased depending on temperature and time of boriding process; surface hardness values of borided materials are approximately 10 times higher than surface hardness values of non-borided AISI316L stainless steel and formation activation energy of boride layer is 149.3 kjmol-1.

🔖

Bu Makaleye Atıf Yap

BAŞMAN, G., ARIKAN, M. M., ARISOY, C., ŞEŞEN, K. (2023). A KINETIC STUDY OF THERMOCHEMICALLY BORIDED AISI 316L STAINLESS STEEL. Journal of Scientific Reports-A, Sayı: 052, 279–296. https://ajindex.com/articles/883334

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Güven, Ş.Y., (2014), Biyouyumluluk ve biyomalzemelerin seçimi. Süleyman Demirel University, Journal of Engineering Sciences and Design, 2(3) SI:BioMechanics, 303-311
  2. Güven, Ş.Y. and Delikanli, K., (2006 Nisan), Metalik biyomalzemelerde son gelişmeler. TİMAK-Tasarım İmalat Analiz Kongresi, Balikesir, 26-28
  3. Patel, N.R. and Gohil, P.P., (2012), A review on biomaterials: Scope, applications and human anatomy significance. International Journal of Emerging Technology and Advanced Engineering, 2(4), 91-101
  4. Geetha, M., Singh, A.K., Asokamani, R. and Gogia, A.K., (2009), Ti based biomaterials, the ultimate choice for orthopaedic implants - A review. Progress in Materials Science, 54, 397–425
  5. Paital, S.R. and Dahotre, N.B., (2009), Calcium phosphate coatings for bio-implant applications: Materials, performance factors, and methodologies. Materials Science and Engineering R, 66, 1-70
  6. Talha, M., Behera C.K. and Sinha, O.P., (2013), A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications. Materials Science and Engineering C, 33(7), 3563–3575
  7. Arsiwala, A., Desai, P. and Patravale, V., (2014), Recent advances in micro/nanoscale biomedical implants. Journal of Controlled Release, 189(10), 25–45
  8. Parsapour, A., Khorasani, S.N. and Fathi, M.H., (2012), Effect of surface treatment and metallic coating on corrosion behavior and biocompatibility of surgical 316L stainless steel implant. Journal of Materials Science and Technology, 28(2), 125–131
  9. Rautray, T.R., Narayanan, R. and Kim, K-H., (2011), Ion implantation of titanium based biomaterials. Progress in Materials Science, 56(8), 1137–1177
  10. Chen, Q. and Thouas, G.A., (2015), Metallic implant biomaterials. Materials Science and Engineering R, 87(1), 1–57
  11. Tiwari, S.K., Mishra, T., Gunjan, M.K., Bhattacharyya, A.S., Singh, T.B. and Singh, R., (2007), Development and characterization of sol–gel silica–alumina composite coatings on AISI 316L for implant applications. Surface & Coatings Technology, 201, 7582–7588
  12. Schwab, H., Prashanth, K.G., Löber, L., Kühn, U. and Eckert, J., (2015), Selective laser melting of Ti-45Nb alloy. Metals, 5, 686-694
  13. Lemons, J.E., Misch-Dietsh, F. and McCracken, M.S., (2015), Biomaterials for dental implants, In Dental Implant Prosthetics (pp. 66-94). Elsevier Inc
  14. Öztürk, O., (2009), Microstructural and mechanical characterization of nitrogen ion implanted layer on 316L stainless steel. N