Dergiler / Turkish Journal of Analytical Chemistry / 2022 / Cilt: 4 - Sayı: 2

A Simple and High Throughput Methodology for Simultaneous Determination of Levodopa and Carbidopa

Sayfa
52–58
Yayın Tarihi
2022-12-29
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The sensitivity of the method was found comparable to other methods depending on the sophisticated electrode modifications and the limits of detection were calculated as sub micromolar levels.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Parkinson's disease (PD) is a degenerative disorder of the central nervous system.
📊
Temel Bulgular & Veri:The motor symptoms of PD disease result from the death of dopamine-generating cells in a region of the mid brain and the dopamine precursor levodopa (L-Dopa) is used for the treatment.
💡
Sonuç & Katkı:The sensitivity of the method was found comparable to other methods depending on the sophisticated electrode modifications and the limits of detection were calculated as sub micromolar levels.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:L-Dopa · Carbidopa · pencil graphite electrode

Abstract

Parkinson's disease (PD) is a degenerative disorder of the central nervous system. The motor symptoms of PD disease result from the death of dopamine-generating cells in a region of the mid brain and the dopamine precursor levodopa (L-Dopa) is used for the treatment. Carbidopa (Car) is administered in association with L-Dopa in pharmaceutical formulation as an inhibitor on the decarboxylase activity. Thus, their simultaneous determination is of great importance because of their co-existence in pharmaceutical preparations. Present study deals with a simple method development for simultaneous voltammetric determination of L-Dopa and Car at a pencil graphite electrode (PGE) via monitoring the reduction peak of L-Dopa and the second oxidation peak of Car. The sensitivity of the method was found comparable to other methods depending on the sophisticated electrode modifications and the limits of detection were calculated as sub micromolar levels.

🔖

Bu Makaleye Atıf Yap

KIRLANGIÇ, İ., ÖZDOKUR, K. V., ERTAS, F. N. (2022). A Simple and High Throughput Methodology for Simultaneous Determination of Levodopa and Carbidopa. Turkish Journal of Analytical Chemistry, Cilt: 4 - Sayı: 2, 52–58. https://ajindex.com/articles/870919

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (3)

  1. Siddiqui MR, Al Othman ZA, Rahman N. Analytical techniques in pharmaceutical analysis: A review. Arabian Journal of Chemistry 2017; 10: 1409–1421. Doi: 10.1016/j.arabjc.2013. 04.016 Lee MS and Kerns EH. LC/MS applications in drug development, Mass Spectrometry Reviews, 1999; 18: 187- 279. Doi: 10.1002/(SICI)1098-2787
  2. Ge L, Li SP, Lisak G, Advanced sensing technologies of phenolic compounds for pharmaceutical and biomedical analysis. Journal of Pharmaceutical and Biomedical Analysis, 2020; 1795: Article 112913. Doi: 10.1016/j.jpba.2019.112913 Özkan SA, Uslu B, Aboul-Enein HY. Analysis of pharmaceuticals and biological fluids using modern electroanalytical techniques. Critical Reviews in Analytical Chemistry, 2003; 33(3):155–181. Doi: 10.1080/713609162 Uslu B, Ozkan SA, Electroanalytical Application of Carbon Based Electrodes to the Pharmaceuticals. Anal. Lett. 2006; 40: 817-853. Doi: 10.1080/00032710701242121 Gupta VK, Jain R, Radhapyari K, Jadon N, Agarwal, S. Voltammetric Techniques for the Assay of Pharmaceuticals--A Review. Anal. Biochemistry; 2011. 408: 179-196 DOI: 10.1016/j.ab.2010.09.027 Antonini A, Yegin A, Preda C, Bergmann L, Poewe W. Global long-term study on motor and non-motor symptoms and safety of levodopa-carbidopa intestinal gel in routine care of advanced Parkinson's disease patients; 12-month interim outcomes. Parkinsonism & Related Disorders 2014. 21 (3):231–35. http://dx.doi.org/10.1016/j.parkreldis. 2014. 12.012 Ardakani MM, Khoshroo A. Nano composite system based on coumarin derivative–titanium dioxide nanoparticles and ionic liquid: Determination of levodopa and carbidopa in human serum and pharmaceutical formulations. Analytica Chimica Acta 2013; 798: 25–32. http://dx.doi.org/10.1016/j.aca.2013.08.045
  3. Bugamelli F, Marcheselli C, Barba E, Raggi MA. Determination of L-Dopa, carbidopa, 3-O-methyldopa and entacapone in human plasma by HPLC–ED. Journal of Pharmaceutical and Biomedical Analysis, 2011; 54: 562–567. Doi:10.1016/j.jpba.2010.09.042 Ozdokur KV, Engin E, Yengin C, Ertas H, Ertas, FN. Determination of Carbidopa, Levodopa, and Droxidopa by High-Performance Liquid Chromatography-Tandem Mass Spectrometry. Analytical Letters, 2017; 51(1-2): 73-82. Doi: 10.1080/00032719.2017.1316283 Ardakani M, Taleat Z, Khoshroo A, Beitollahi H, Dehghani H. Electrocatalytic oxidation and voltammetric determination of levodopa in the presence of carbidopa at the surface of a nanostructure based electrochemical sensor. Biosensors and Bioelectronics,