Dergiler / Turkish Journal of Physics / 2017 / Cilt: 41 - Sayı: 6

Deconvolution analysis of thermoluminescent glow curves in various commercial dosimeters using two different approaches in the framework of the one-trap, one-recombination model

Sayfa
477–490
Yayın Tarihi
2017-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The results of this study suggest that the Lambert W-function is promising in revealing the physical meaning of trap-charge and recombination mechanisms for the characterization of materials throughout physical-based sciences.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This paper reports kinetic analysis on the thermoluminescence (TL) glow peaks of various widespread luminescence dosimeters.
📊
Temel Bulgular & Veri:According to the results of this study, the activation energies of the main dosimetric peaks are estimated as 2.05 $\pm $ 0.11, eV, 1.23 $\pm $ 0.05 eV, and 1.11 $\pm $ 0.06 eV for LiF based dosimeters (TLD100, TLD600, TLD700), Al$_{2}$O$_{3}$:C (TLD500), and BeO dosimeters, respectively.
💡
Sonuç & Katkı:The results of this study suggest that the Lambert W-function is promising in revealing the physical meaning of trap-charge and recombination mechanisms for the characterization of materials throughout physical-based sciences.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Deconvolution · thermoluminescence (TL) · general order kinetic (GOK)

Abstract

This paper reports kinetic analysis on the thermoluminescence (TL) glow peaks of various widespread luminescence dosimeters. A common general order kinetic (GOK) approximation and a relatively recently suggested Lambert W-function equation were used. The activation energies and the order of kinetic parameters are the main subjects of the present study. According to the results of this study, the activation energies of the main dosimetric peaks are estimated as 2.05 $\pm $ 0.11, eV, 1.23 $\pm $ 0.05 eV, and 1.11 $\pm $ 0.06 eV for LiF based dosimeters (TLD100, TLD600, TLD700), Al$_{2}$O$_{3}$:C (TLD500), and BeO dosimeters, respectively. Moreover, a number of other peaks were deconvolved and investigated in terms of kinetic parameters and frequency factors. Additionally, the advantages of the Lambert equation, being completely analytical, are reported and compared to those of the GOK method while deconvolving TL glow curves. The results of this study suggest that the Lambert W-function is promising in revealing the physical meaning of trap-charge and recombination mechanisms for the characterization of materials throughout physical-based sciences.

🔖

Bu Makaleye Atıf Yap

ŞAHİNER, E. (2017). Deconvolution analysis of thermoluminescent glow curves in various commercial dosimeters using two different approaches in the framework of the one-trap, one-recombination model. Turkish Journal of Physics, Cilt: 41 - Sayı: 6, 477–490. https://ajindex.com/articles/723901

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...