Journals / Turkish Journal of Physics / 2017 / Cilt: 41 - Sayı: 6

Deconvolution analysis of thermoluminescent glow curves in various commercial dosimeters using two different approaches in the framework of the one-trap, one-recombination model

Pages
477–490
Publication Date
2017-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to the results of this study, the activation energies of the main dosimetric peaks are estimated as 2.05 $\pm $ 0.11, eV, 1.23 $\pm $ 0.05 eV, and 1.11 $\pm $ 0.06 eV for LiF based dosimeters (TLD100, TLD600, TLD700), Al$_{2}$O$_{3}$:C (TLD500), and BeO dosimeters, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper reports kinetic analysis on the thermoluminescence (TL) glow peaks of various widespread luminescence dosimeters.
📊
Key Findings & Data:According to the results of this study, the activation energies of the main dosimetric peaks are estimated as 2.05 $\pm $ 0.11, eV, 1.23 $\pm $ 0.05 eV, and 1.11 $\pm $ 0.06 eV for LiF based dosimeters (TLD100, TLD600, TLD700), Al$_{2}$O$_{3}$:C (TLD500), and BeO dosimeters, respectively.
💡
Conclusion & Impact:The results of this study suggest that the Lambert W-function is promising in revealing the physical meaning of trap-charge and recombination mechanisms for the characterization of materials throughout physical-based sciences.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Deconvolution · thermoluminescence (TL) · general order kinetic (GOK)

Abstract

This paper reports kinetic analysis on the thermoluminescence (TL) glow peaks of various widespread luminescence dosimeters. A common general order kinetic (GOK) approximation and a relatively recently suggested Lambert W-function equation were used. The activation energies and the order of kinetic parameters are the main subjects of the present study. According to the results of this study, the activation energies of the main dosimetric peaks are estimated as 2.05 $\pm $ 0.11, eV, 1.23 $\pm $ 0.05 eV, and 1.11 $\pm $ 0.06 eV for LiF based dosimeters (TLD100, TLD600, TLD700), Al$_{2}$O$_{3}$:C (TLD500), and BeO dosimeters, respectively. Moreover, a number of other peaks were deconvolved and investigated in terms of kinetic parameters and frequency factors. Additionally, the advantages of the Lambert equation, being completely analytical, are reported and compared to those of the GOK method while deconvolving TL glow curves. The results of this study suggest that the Lambert W-function is promising in revealing the physical meaning of trap-charge and recombination mechanisms for the characterization of materials throughout physical-based sciences.

🔖

Cite This Article

ŞAHİNER, E. (2017). Deconvolution analysis of thermoluminescent glow curves in various commercial dosimeters using two different approaches in the framework of the one-trap, one-recombination model. Turkish Journal of Physics, Cilt: 41 - Sayı: 6, 477–490. https://ajindex.com/articles/723901

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...