Dergiler / The European Research Journal / 2022 / Cilt: 8 - Sayı: 6

Contribution of bronchoscopic lavage to the diagnosis of smear negative pulmonary tuberculosis

Sayfa
845–850
Yayın Tarihi
2022-11-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusions: Performing Xpert examinations on bronchoscopic materials of patients with negative sputum examinations significantly increase the rate of early diagnosis.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: Sputum acid-fact bacilli (AFB) and Xpert examinations are the most commonly used methods in early diagnosis for pulmonary tuberculosis.
📊
Temel Bulgular & Veri:Waiting for culture results for diagnosis causes delay in treatment and increases the risk of disease transmission.
💡
Sonuç & Katkı:Conclusions: Performing Xpert examinations on bronchoscopic materials of patients with negative sputum examinations significantly increase the rate of early diagnosis.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Sputum · smear negative · pulmonary tuberculosis

Abstract

Objectives: Sputum acid-fact bacilli (AFB) and Xpert examinations are the most commonly used methods in early diagnosis for pulmonary tuberculosis. It becomes difficult for the clinician to initiate treatment in patients with negative sputum smear and Xpert examinations at the stage of diagnosis. Waiting for culture results for diagnosis causes delay in treatment and increases the risk of disease transmission. We aimed to investigate the contribution of bronchoscopic lavage (BL) obtained with flexible fiberoptic bronchoscopy (FOB) to the diagnosis of tuberculosis. Methods: The BL results of 36 patients hospitalized in the tuberculosis clinic who were clinically suspected of tuberculosis, but whose sputum AFB and Xpert results were negative, and whose bronchoscopic lavages were taken by FOB, were retrospectively evaluated. Results: BL Xpert examination was the method that made the most contribution to the diagnosis with a rate of 27.7%. BL smear AFB results did not contribute to the diagnosis statistically. Sputum and BL tuberculosis culture results were found to be close to each other. In total, the diagnosis of 50% of the patients was confirmed. Conclusions: Performing Xpert examinations on bronchoscopic materials of patients with negative sputum examinations significantly increase the rate of early diagnosis.

🔖

Bu Makaleye Atıf Yap

ŞAHİN, M. E., BULUT, S. (2022). Contribution of bronchoscopic lavage to the diagnosis of smear negative pulmonary tuberculosis. The European Research Journal, Cilt: 8 - Sayı: 6, 845–850. https://ajindex.com/articles/703920

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Global Tuberculosis Report 2019. https://www.who.int/tb/global-report-2019. Accessed 27 Jun 2020
  2. Toman K. How many bacilli are present in a sputum specimen found positive by smear microscopy? In: Frieden T. editors. Toman’s Tuberculosis Case detection, treatment, and monitoring – questions and answers, Geneva: World Health Organization; 2004, p. 11
  3. Siddiqi K, Lambert M-L, Walley J. Clinical diagnosis of smear-negative pulmonary tuberculosis in low-income countries: the current evidence. Lancet Infect Dis 2003;3:288-96
  4. Barnard DA, Irusen EM, Bruwer JW, Plekker D, Whitelaw AC, Deetlefs JC, et al. The utility of Xpert MTB/RIF performed on bronchial washings obtained in patients with suspected pulmonary tuberculosis in a high prevalence setting. BMC Pulm Med 2015;15:103
  5. Bachh A, Gupta R, Haq I, Varudkar HG. Diagnosing sputum/smear-negative pulmonary tuberculosis: Does fibre-optic bronchoscopy play a significant role? Lung India 2010;27:58
  6. Kacar N, Bıcer B, Tuksavul F, Guclu SZ. [Diagnostic value of bronchial lavage, bronchoalveolar lavage and postbronchoscopic sputum in smear negative pulmonary tuberculosis]. Turkiye Klinikleri Arch Lung 2004;5:200-2. [Article in Turkish] 7. Balbay OA, Calışır HC, Erturk A, Ogretensoy M. [The diagnostic value of bronchial lavage, bronchial biopsy and postbronchoscopic sputum in smear-negative pulmonary tuberculosis]. Tüberküloz ve Toraks Dergisi 2001;49:124-8. [Article in Turkish] 8. Alp AI, Karlikaya C, Hatipoglu ON, Caglar T, Otkun M. [Diagnostic value of fiberoptic bronchoscopy in sputum smear negative pulmonary tuberculosis]. Tüberküloz ve Toraks Dergisi 2002;50:278-87. [Article in Turkish] 9. Willcox PA, Benatar SR, Potgieter PD. Use of the flexible fibreoptic bronchoscope in diagnosis of sputum-negative pulmonary tuberculosis. Thorax 1982;37:598-601
  7. Charoenratanakul S, Dejsomritrutai W, Chaiprasert A. Diagnostic role of fiberoptic bronchoscopy in suspected smear negative pulmonary tuberculosis. Respir Med 1995;89:621-3
  8. Pathakumari B, Prabhavathi M, Anbarasu D, Paramanandhan P, Raja A. Dynamic IgG antibody response to immunodominant antigens of M. tuberculosis for active TB diagnosis in high endemic settings. Clin Chim Acta 2016;461: 25-33
  9. Helb D, Jones M, Story E, Boehme C, Wallace E, Ho K, et al. Rapid detection of mycobacterium tuberculosis and rifampin resistance by use of on-demand, near-patient technology. J Clin Microbiol 2010;48:229-37
  10. World Health Organization. Automated