Dergiler / Türk Oftalmoloji Dergisi / 2018 / Cilt: 48 - Sayı: 3

Validity and Reliability of the Glaucoma Knowledge Level Questionnaire

Sayfa
115–121
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

According to factor analysis, the Kaiser-Meyer-Olkin score was0.760 and Bartlett’s test indicated p

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: The present study was conducted to develop an instrument for measuring adults’ glaucoma knowledge levels and toestablish the instrument’s validity and reliability.Materials and Methods: The study group consisted of 811 persons aged 40-80 years who presented to primary health care institutionsand did not have a glaucoma diagnosis.
📊
Temel Bulgular & Veri:A 27-item questionnaire measuring level of glaucoma knowledge was created by the study team.Following expert consultation, it was structurally evaluated.
💡
Sonuç & Katkı:According to factor analysis, the Kaiser-Meyer-Olkin score was0.760 and Bartlett’s test indicated p
🔬Tür:Uygulamalı Anket & Alan Araştırması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objectives: The present study was conducted to develop an instrument for measuring adults’ glaucoma knowledge levels and toestablish the instrument’s validity and reliability.Materials and Methods: The study group consisted of 811 persons aged 40-80 years who presented to primary health care institutionsand did not have a glaucoma diagnosis. A 27-item questionnaire measuring level of glaucoma knowledge was created by the study team.Following expert consultation, it was structurally evaluated. The difficulty index and discrimination index were calculated for each item.Factor analysis was used to determine construct validity, Cronbach’s alpha internal consistency coefficient and item-total correlationswere calculated to determine reliability. Confirmatory factor analysis was used to assess the extent to which the factor structure of thescale fit. We analysed correlation with the National Eye Health Education Program (NEHEP) Eye-Q scale in order to evaluate thevalidity of the scale.Results: The final glaucoma knowledge level questionnaire comprised 10 items in one dimension. The discrimination index anddifficulty index ranged between 0.28 to 0.65 and 33 to 61%, respectively. According to factor analysis, the Kaiser-Meyer-Olkin score was0.760 and Bartlett’s test indicated p

🔖

Bu Makaleye Atıf Yap

ÖNSÜZ, M. F., SOYSAL, A., YILDIRIM, N., METİNTAŞ, S., DEMİRTAŞ, Z., DAĞTEKİN, G. (2022). Validity and Reliability of the Glaucoma Knowledge Level Questionnaire. Türk Oftalmoloji Dergisi, Cilt: 48 - Sayı: 3, 115–121. https://ajindex.com/articles/637785

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Labiris G, Katsanos A, Fanariotis M, et al. A proposed methodology for the assessment of glaucoma awareness in Greece: introduction of the EIT8G scale. Eur J Ophthalmol. 2012;22:95-103.
  2. Saw S, Gazzard G, Friedman D, Foster PJ, Devereux JG, Wong ML, Seah S. Awareness of glaucoma and health beliefs of patients suffering primary acute angle closure. Br J Ophthalmol. 2003;87:446-449.
  3. Hoevenaars JG, Schouten JS, van den Borne B, Beckers HJ, Webers CA. Socioeconomic differences in glaucoma patients’ knowledge, need for information and expectations of treatments. Acta Ophthalmol Scand. 2005;84:84-91.
  4. Gökler ME, Öz F, Metintaş S. Reliability and validity of Medical Profession Value Perception Scale and results in medical students. Turkish Journal of Public Health. 2017;15:26-36.
  5. Rao VS, Peralta EA, Rosdahl JA. Validation of a glaucoma knowledge assessment in glaucoma patients. Clin Ophthalmol. 2016;10:1913-1918.
  6. Skoskiewicz-Malinowska K, Kaczmarek U, Zietek M, Malicka B. Validation of the Polish version of the oral health impact profile-14. Adv Clin Exp Med. 2015;24:129-137.
  7. McCowan RJ, McCowan SC. Item Discrimination. Item Analysis for Criterion-Referenced Tests. New York; Center for Development of Human Services; 1999:20-21.
  8. Erkorkmaz Ü, Etikan İ, Demir O, Özdamar K, Sanisoğlu SY. Doğrulayıcı faktör analizi ve uyum indeksleri. Turkiye Klinikleri J Med Sci. 2013;33:210-223. Kline P. A General Description Of Factor Analysis. An Easy Guide to Factor Analysis. New York; Routledge; 1994;10-11.
  9. Arıkan İ, Metintaş S, Kalyoncu C, Yıldız Z. Kardiyovasküler Hastalıklar Risk Faktörleri Bilgi Düzeyi (KARRİF-BD) Ölçeği’nin geçerlik ve güvenirliği. Türk Kardiyol Dern Araş. 2009;37:35-40.
  10. Doi Y, Minowa M. Factor structure of the 12-item General Health Questionnaire in the Japanese general adult population. Psychiatry Clin Neurosci. 2003;57:379-383. National Eye Health Education Program (NEHEP) Program. Eye-Q Test. https://nei.nih.gov/sites/default/files/nehep-pdfs/EyeQTest_for_ Toolkit.pdf available date:14.03.2017.
  11. Yen MT, Wu CY, Higginbotham EJ. Importance of increasing public awareness regarding glaucoma. Arch Ophthalmol. 1996;114:635. Costa VP, Spaeth GL, Smith M, Uddoh C, Vasconcellos JP, Kara-Jose N. Patient education in glaucoma: what do patients know about glaucoma? Arq Bras Oftalmol 2006;69:923-927.
  12. Adegbehingbe BO, Bisiriyu LA. Knowledge, attitudes and self care practices associated with glaucoma among hispital workers in Ile-Ife, Osun State, Nigeria. Tanzan J Health