Dergiler / Turkish Journal of Chemistry / 1999 / Cilt: 23 - Sayı: 4

A Modified Potentiometric Method for the Estimation of Phenol in Aqueous Systems

Sayfa
415–422
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The lowest detection limit achieved was 50 mg phenol/L and the method is well-suited to direct aqueous phase municipal sewage, home effluents and industrial discharges for phenol determination.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A modified potentiometric titration is proposed for the estimation of phenol in aqueous systems.
📊
Temel Bulgular & Veri:The method incorporates titrants in a concentration range several orders of magnitude greater than that of phenol in the aqueous phase.
💡
Sonuç & Katkı:The lowest detection limit achieved was 50 mg phenol/L and the method is well-suited to direct aqueous phase municipal sewage, home effluents and industrial discharges for phenol determination.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Turk. J. Chem. · (1999) · 415-422. Full text: pdf Other articles published in the same issue: Turk. J. Chem.

Özet

A modified potentiometric titration is proposed for the estimation of phenol in aqueous systems. The method is evolved on the basis of a critical dependence of pH on log V rather than simple V, as used in conventional potentiometric titrations. The method incorporates titrants in a concentration range several orders of magnitude greater than that of phenol in the aqueous phase. Derivative potentiometric curves so obtained provide a clear exposition of the equivalence point and the overall error is found to be between \pm 1.0 and 1.5%. The range of phenol concentration investigated was from 10-2 to 10-3 M. and that of sodium hydroxide used as the titrant from 10-1 to 4.0 M. The maximized titrant concentrations were found to be helpful in controlling the dilution problem during titration. The lowest detection limit achieved was 50 mg phenol/L and the method is well-suited to direct aqueous phase municipal sewage, home effluents and industrial discharges for phenol determination.

Abstract

A modified potentiometric titration is proposed for the estimation of phenol in aqueous systems. The method is evolved on the basis of a critical dependence of pH on log V rather than simple V, as used in conventional potentiometric titrations. The method incorporates titrants in a concentration range several orders of magnitude greater than that of phenol in the aqueous phase. Derivative potentiometric curves so obtained provide a clear exposition of the equivalence point and the overall error is found to be between \pm 1.0 and 1.5%. The range of phenol concentration investigated was from 10-2 to 10-3 M. and that of sodium hydroxide used as the titrant from 10-1 to 4.0 M. The maximized titrant concentrations were found to be helpful in controlling the dilution problem during titration. The lowest detection limit achieved was 50 mg phenol/L and the method is well-suited to direct aqueous phase municipal sewage, home effluents and industrial discharges for phenol determination.

🔖

Bu Makaleye Atıf Yap

HUMA, F., JAFFAR, M., MASUD, K. (2022). A Modified Potentiometric Method for the Estimation of Phenol in Aqueous Systems. Turkish Journal of Chemistry, Cilt: 23 - Sayı: 4, 415–422. https://ajindex.com/articles/602479

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...