Dergiler / Turkish Journal of Chemistry / 2018 / Cilt: 42 - Sayı: 2

Simultaneous determination of copper(II) and zinc(II) via simple acid-base titrimetry using glass pH electrode

Sayfa
257–263
Yayın Tarihi
2022-11-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Copper(II) and zinc(II) were simultaneously determined with approximately 5 ppm detection limits and the developed method was validated by performing the titration with known sample mixtures and a certificated alloy sample.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The combination of potentiometric methods with multivariate calibration techniques allows complex mixtures to be analyzed.
📊
Temel Bulgular & Veri:Partial least squares 1, one of the multivariate calibration techniques, was used in the analysis of titrimetric data.
💡
Sonuç & Katkı:Copper(II) and zinc(II) were simultaneously determined with approximately 5 ppm detection limits and the developed method was validated by performing the titration with known sample mixtures and a certificated alloy sample.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

The combination of potentiometric methods with multivariate calibration techniques allows complex mixtures to be analyzed. In this study, a new method was developed and reported for simultaneous determination of copper(II) and zinc(II) cations in a mixture by titrimetric methods. The developed method permits simultaneous cation analysis with low detection limits, just by using a pH electrode. This work has achieved the challenging goal of developing a cost-effective and applicable method that can be applied in most laboratories due to independence of any chemical instruments. Partial least squares 1, one of the multivariate calibration techniques, was used in the analysis of titrimetric data. Copper(II) and zinc(II) were simultaneously determined with approximately 5 ppm detection limits and the developed method was validated by performing the titration with known sample mixtures and a certificated alloy sample.

🔖

Bu Makaleye Atıf Yap

KENAR, A., ERGÜN, E. G. C. (2022). Simultaneous determination of copper(II) and zinc(II) via simple acid-base titrimetry using glass pH electrode. Turkish Journal of Chemistry, Cilt: 42 - Sayı: 2, 257–263. https://ajindex.com/articles/601990

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (16)

  1. Abbasi-Tarighat, M.; Nabavi, M.; Mohammadizadeh, M. R. Spectrochim. Acta A 2015, 15, 54-62
  2. Moradi, R.; Jameh-Bozorghi, S.; Niazi, A. APCBEE Procedia 2012, 3, 65-59
  3. Abbasi-Tarighat, M.; Shahbazi, E.; Niknam, K. Food Chem. 2013, 138, 991-997
  4. Ghavami, R.; Najafi, A.; Hemmateenejad, B. Spectrochim. Acta A 2008, 70, 824-834
  5. Pei, J.; Tercier-Waeber, M. L.; Buffle, J. Anal. Chem. 2000, 72, 161-171
  6. Otto, M.; Thomas, J. D. R. Anal. Chem. 1985, 57, 2647-2651
  7. Forster, R.; Regan, F.; Diamond, D. Anal. Chem. 1991, 63, 879-882
  8. Forster, R.; Diamond, D. Anal. Chem. 1992, 64, 1721-1728
  9. Skoog, D. A.; Holler, F. J.; Nieman, T. A. Principles of Instrumental Analysis; Brooks/Cole, Thomson Learning: Belmont, CA, USA, 2007
  10. Lindberg, W.; Kowalski, B. Anal. Chim. Acta 1988, 206, 125-135
  11. Ni, Y. N.; Wu, Y. L. Anal. Chim. Acta 1997, 354, 233-240
  12. Ni, Y. N. Anal. Chim. Acta 1998, 367, 145-152
  13. Ni, Y. N.; Wu, A. G. Anal. Chim. Acta 1999, 390, 117-123
  14. Ni, Y.; Kokot, S. Anal. Chim. Acta 2008, 626, 130-146
  15. Brereton, G. R. Chemometrics: Application of Mathematics and Statistics to Laboratory Systems; Ellis Horwood: Chichester, UK, 1990
  16. Brereton, G. R. Analyst 1997, 122, 1521-1529