The proposed method enablessimple, rapid, and in situ determination of total tocopherol content of serum by taking advantage of optical sensors.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Lipid-soluble endogenous antioxidants, such as tocopherols, protect biological structures from oxidativedamage through their chain-breaking ability and thus the development of a simple method for tocopherol determinationis important.
📊
Temel Bulgular & Veri:The proposed method is based on the use of acopper(II)-neocuproine complex (Cu(II)-Nc) reagent immobilized onto a Nafion membrane, and the absorbance changesassociated with the formation of Cu(I)-Nc chelate on the membrane strip as a result of reaction with serum tocopherolswere measured at 450 nm.
💡
Sonuç & Katkı:The proposed method enablessimple, rapid, and in situ determination of total tocopherol content of serum by taking advantage of optical sensors.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Lipid-soluble endogenous antioxidants, such as tocopherols, protect biological structures from oxidativedamage through their chain-breaking ability and thus the development of a simple method for tocopherol determinationis important. In this study, a novel optical sensor-based method was proposed for determining total tocopherol content(TTC) of serum, with selectivity for α-tocopherol over β -carotene. The proposed method is based on the use of acopper(II)-neocuproine complex (Cu(II)-Nc) reagent immobilized onto a Nafion membrane, and the absorbance changesassociated with the formation of Cu(I)-Nc chelate on the membrane strip as a result of reaction with serum tocopherolswere measured at 450 nm. The calibration graph of α-tocopherol was linear with a slope of 1.96 × 10 4 L mol −1cm −1.The limit of detection and limit of quantification for tocopherol in the proposed method were found as 0.50 and 1.67 µM,respectively. The TTC value of synthetic serum samples was determined with the use of the proposed method, and theobtained results were comparable to those of the CUPRAC spectrophotometric method. The proposed method enablessimple, rapid, and in situ determination of total tocopherol content of serum by taking advantage of optical sensors.

🔖

Bu Makaleye Atıf Yap

BENER, M., APAK, R. (2022). Novel optical sensor-based method for determining total tocopherol content in serum. Turkish Journal of Chemistry, Cilt: 42 - Sayı: 6, 1687–1694. https://ajindex.com/articles/601837

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (28)

  1. Valko, M.; Rhodes, C.; Moncol, J.; Izakovic, M. M.; Mazur, M. Chem.-Biol. Interact. 2006, 160, 1-40
  2. Gülçin, İ. Arch. Toxicol. 2012, 86, 345-391
  3. Patterson, R. E.; White, E.; Kristal, A. R.; Neuhouser, M. L.; Potter, J. D. Cancer Cause. Control 1997, 8, 786-802
  4. Moushumi, L.; Sumati, B. Phytother. Res. 1994, 8, 237-240
  5. Ching, L. S.; Mohamed, S. J. Agric. Food Chem. 2001, 49, 3101-3105
  6. Jiang, Q.; Christen, S.; Shigenaga, M. K.; Ames, B. N. Am. J. Cln. Nutr. 2001, 74, 714-722
  7. Curran, F. J. M.; Sattar, N.; Talwar, D.; Baxter, J. N.; Imrie, C. W. Brit. J. Surg. 2000, 87, 301-305
  8. Palan, P. R.; Mikhail, M. S.; Goldberg, G. L.; Basu, J.; Runowicz, C. D.; Romney, S. L. Clin. Cancer Res. 1996, 2, 181-185
  9. Rimm, E. B.; Stampfer, M. J.; Ascherio, A.; Giovannucci, E.; Colditz, G. A.; Willett, W. C. New Engl. J. Med. 1993, 328, 1450-1456
  10. Tanyel, M. C.; Mancano, L. D. Am. Fam. Physician 1997, 55, 197-201
  11. Handelman, G. J. Nutr. Rev. 1997, 55, 369-370
  12. Kappus, H.; Diplock, A. T. Free Radical Bio. Med. 1992, 13, 55-74
  13. Leppälä, J. M.; Virtamo, J.; Fogelholm, R.; Huttunen, J. K.; Albanes, D.; Taylor, P. R.; Heinonen, O. P. Arterioscl. Throm. Vas. 2000, 20, 230-235
  14. Kock, R.; Seitz, S.; Delvoux, B.; Greiling, H. Clin. Chem. Lab. Med. 1997, 35, 371-378
  15. Melchert, H. U.; Pabel, E. J. Chromatogr. A 2000, 896, 209-215
  16. Gimeno, E.; Castellote, A. I.; Lamuela-Raventos, R. M.; de La Torre-Boronat, M. C.; Lopez-Sabater, M. C. J. Chromatogr-Biomed. 2001, 758, 315-322
  17. Nirungsan, K.; Thongnopnua, P. Biomed. Chromatogr. 2006, 20, 774-781
  18. Emmerie, A.; Engel, C. Recl. Trav. Chim. Pay-B 1938, 57, 1351-1355
  19. Natelson S. Microtechniques of Clinical Chemistry for the Routine Laboratory; C.C. Thomas: Springfield, IL, USA, 1957
  20. Martinek, R. G. Clin. Chem. 1964, 10, 1078-1086
  21. Tsen, C. C. Anal. Chem. 1961, 33, 849-851
  22. Fabianek, J.; DeFilippi, J.; Rickards, T.; Herp, A. Clin. Chem. 1968, 14, 456-462
  23. Kayden, H. J.; Chow, C. K.; Bjornson, L. K. J. Lipid. Res. 1973, 14, 533-540
  24. Taylor, S. L.; Lamden, M. P.; Tappel, A. L. Lipids 1976, 530-538
  25. Apak, R.; Güçlü, K.; Özyürek, M.; Karademir, S. E.; Altun, M. Free Radical Res. 2005, 39, 949-961
  26. Zhao, S.; Zhang, K.; Bai, Y.; Yang, W.; Sun, C. Bioelectrochemistry 2006, 69, 158-163
  27. Boonsiri, P.; Pooart, J.; Tangrassameeprasert, R.; Hongsprabhas, P. Asia Pac. J. Clin. Nutr. 2007, 16, 47-51
  28. Aebischer, C. P.; Schierle, J.; Schüep, W. Method. Enz