Dergiler / Turkish Journal of Chemistry / 2019 / Cilt: 43 - Sayı: 4

A novel silver(I)-selective PVC membrane sensor and its potentiometric applications

Sayfa
1149–1158
Yayın Tarihi
2022-11-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In real water samples prepared by standard addition method, recoveries in the range of 82.30%–95.15% were obtained.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Silver(I)-selective sensors were prepared from a solid-state contact polyvinyl chloride (PVC) membrane.(Z)-2-(2-((3-(2-hydroxyphenyl)-5-(p-tolyl)-1H -pyrrol-2-yl)imino)-5-(p-tolyl)-2H -pyrrol-3-yl)phenol was synthesized as an ionophore molecule and embedded in the silver(I)-selective PVC membrane composition.
📊
Temel Bulgular & Veri:The optimum membrane composition was determined as 2.5% ionophore, 61.7% bis-(2-ethylhexyl)sebacate, 1.0% potassium tetrakis (pchlorophenyl) borate, and 34.8% PVC.
💡
Sonuç & Katkı:In real water samples prepared by standard addition method, recoveries in the range of 82.30%–95.15% were obtained.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Silver(I)-selective sensors were prepared from a solid-state contact polyvinyl chloride (PVC) membrane.(Z)-2-(2-((3-(2-hydroxyphenyl)-5-(p-tolyl)-1H -pyrrol-2-yl)imino)-5-(p-tolyl)-2H -pyrrol-3-yl)phenol was synthesized as an ionophore molecule and embedded in the silver(I)-selective PVC membrane composition. The optimum membrane composition was determined as 2.5% ionophore, 61.7% bis-(2-ethylhexyl)sebacate, 1.0% potassium tetrakis (pchlorophenyl) borate, and 34.8% PVC. The developed sensor exhibited a linear potential change E = 67.42 (–log [Ag + ]) + 1152.9 and R 2 = 0.9960) in the varying concentration range of 1.0 × 10 −1to 1.0 × 10 −5 mol L −1 silver ions. This sensor shows a detection limit of 7.3 × 10 −7 mol L −1. The proposed sensor showed a good potential change with high sensitivity even in a wide range of pH values (2.0–11.0). The proposed sensor had a quick electrochemical response of less than 3 s with good selectivity and repeatability. The sensor was also successfully applied in the analysis of real water samples. In real water samples prepared by standard addition method, recoveries in the range of 82.30%–95.15% were obtained.

🔖

Bu Makaleye Atıf Yap

DELİGÖNÜL, N., IŞILDAK, Ö., ÖZBEK, O. (2022). A novel silver(I)-selective PVC membrane sensor and its potentiometric applications. Turkish Journal of Chemistry, Cilt: 43 - Sayı: 4, 1149–1158. https://ajindex.com/articles/601660

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (25)

  1. Malinowska, E.; Brzozka, Z.; Kasiura, K.; Egberink, R. J. M.; Reinhoudt, D. N. Anal. Chim. Acta 2004, 298, 253-258
  2. Chen, L.; Ju, H.; Zeng, X.; He, X.; Zhang, Z. Anal. Chim. Acta 2001, 437, 191-197
  3. Purcell, T. W.; Peters, J. J. Environ. Toxicol. Chem. 1998, 17, 539-546
  4. Furno, F.; Morley, K. S.; Wong, B.; Sharp, B. L.; Arnold, P. L.; Howdle, S. M.; Bayson, R.; Brown, R.; Winship, P. D.; Reid, H. J. J. Antimicrob. Chemother. 2004, 4, 1019-1024
  5. Farghaly, O. A.; Abdel Hameed, R. S.; Abu-Nawwas, A. H. Int. J. Electrochem. Sci. 2014, 9, 3287-3318
  6. Ardakani, M. M.; Dehghani, H.; Jalayer, M.; Zare, H. R. Anal. Sci. 2004, 20, 1667-1672
  7. Shahrokhian, S.; Taghani, A.; Moattar, F. Electroanalysis 2002, 14, 1621-1628
  8. Antonisse, M. M. G.; Reinhoudt, D. N. Electroanalysis 1999, 11, 1035-1048
  9. Ding, J.; Qin, W. Y.; Zhang, Y.; Wang, X. Biosens. Bioelectron. 2013, 45, 148-151
  10. Reinoso-García, M. M.; Dijkman, A.; Verboom, W.; Reinhoudt, D. N.; Malinowska E.; Wojciechowska, D.; Pietrzak, M.; Selucky, P. Eur. J. Org. Chem. 2005, 10, 2131-2138
  11. Lu, J. Q.; Pang, D. W.; Zeng, X. S.; He, X. W. J. Electroanal. Chem. 2004, 568, 37-43
  12. Kumar, M.; Mahajan, R. K.; Sharma, V.; Sing, H.; Sharma N.; Kaur, I. Tetrahedron Lett. 2001, 42, 5315-5318
  13. Chen, L.; Zeng, X.; He, X.; Zhengzhi; Zhang. Fresenius J. Anal. Chem. 2000, 367, 535-538
  14. Deligonul, N.; Browne, A. R.; Golen, J. A.; Rheingold, A. L.; Gray, T. G. Organometallics 2014, 33, 637-643
  15. Amin, A. N.; El-Khouly, M. E.; Navaneetha K. S.; Zandler, M. E.; Fukuzumi S.; D’Souza, F. Chem. Comm. 2012, 48, 206-208
  16. Deligonul, N.; Gray, T. G. Inor. Chem. 2013, 52, 13048-13057
  17. Teets, T. S.; Partyka, D. V.; Esswein A. J.; Updegraff, J. B.; Zeller, M. A.; Hunter, D.; Gray, T. G. Inorg. Chem. 2007, 46, 6218-6220
  18. Loudet, A.; Bandichhor, R.; Burgess, K.; Palma, A.; McDonnell, S. O.; Hall, M. J.; O’Shea, D. F. Org. Lett. 2008, 10, 4771-4774
  19. IUPAC. Pure Appl. Chem. 1976, 48, 127-132
  20. Buck, P. D.; Lindner, E. Pure Appl. Chem. 1994, 66, 2527-2536
  21. Yolcu, M. PhD, Department of Chemistry, Ondokuz Mayıs University, Turkey, 2008
  22. Topcu, C.; Coldur, F.; Andac, M.; Isildak, I.; Senyüz, N.; Bati, H. Curr. Anal. Chem. 2011, 7, 136-145
  23. Demirel, A.; Dogan, A.; Akkus, G.; Yilmaz, M.; Kilic, E. Electroanalysis 2006, 18, 1019-1027
  24. Shamsipur, M.; Kazemi, S. Y.; Sharghi, H. Sensors 2007, 7, 438-447
  25. Gupta, V. K.; Antonijevic, M. M.; Chandra, S.; Agarwal, S. Sensors 2002,