Dergiler / Turkish Journal of Chemistry / 2022 / Cilt: 46 - Sayı: 2

Schiff base functionalized silica gel for simultaneous separation and preconcentration of Cu(II), Ni(II), and Cd(II) in pharmaceuticals and water samples

Sayfa
459–474
Yayın Tarihi
2022-11-03
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The method was successfully applied to eye drop, anesthetic, serum, tap water, mineral water, and spring water samples.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A method for separation and preconcentration of Cu(II), Ni(II), and Cd(II) using N-N’-bis(5-methoxsalicylidene)-2-hydroxy1,3-propanediamine modified silica gel was improved for aqueous samples and pharmaceuticals.
📊
Temel Bulgular & Veri:The experimental conditions including pH value, sample volume, eluent type and volume, sorbent mass, sample, and eluent flow rates were optimized with univariate and multivariate optimization tools.
💡
Sonuç & Katkı:The method was successfully applied to eye drop, anesthetic, serum, tap water, mineral water, and spring water samples.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

A method for separation and preconcentration of Cu(II), Ni(II), and Cd(II) using N-N’-bis(5-methoxsalicylidene)-2-hydroxy1,3-propanediamine modified silica gel was improved for aqueous samples and pharmaceuticals. Determination of the analytes was achieved by inductively coupled plasma optic emission spectrometry. The experimental conditions including pH value, sample volume, eluent type and volume, sorbent mass, sample, and eluent flow rates were optimized with univariate and multivariate optimization tools. The relative standard deviations of the method were 2.9% for Cu(II), 3.0% for Ni(II), and 3.3% for Cd(II) with recovery values between 98.8 ± 3.2–101.5 ± 3.0%. The limits of detection were found to be 62.4, 39.5, and 28.2 ng $L^{–1$} for Cu(II), Ni(II), and Cd(II), respectively. The accuracy of the suggested procedure was tested with the certified reference material (Certipur ICP multi-element standard solution IV) and addition-recovery experiments. The method was successfully applied to eye drop, anesthetic, serum, tap water, mineral water, and spring water samples.

🔖

Bu Makaleye Atıf Yap

BAĞDAT, S., TOKAY, F. (2022). Schiff base functionalized silica gel for simultaneous separation and preconcentration of Cu(II), Ni(II), and Cd(II) in pharmaceuticals and water samples. Turkish Journal of Chemistry, Cilt: 46 - Sayı: 2, 459–474. https://ajindex.com/articles/601351

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Speich M, Pineau A, Ballereau F. Minerals, trace elements and related biological variables in athletes and during physical activity. Clinica Chimica Acta 2001
  2. doi: 10.1016/S0009-8981(01)00598-8 2. Tokay F, Bağdat S. Solid phase extraction and preconcentration of some metal ions using Schiff base immobilised silica gel followed by ICPOES. International Journal of Environmental Analytical Chemistry 2019
  3. 99 (15): 1528-1539. doi: 10.1080/03067319.2019.1625341 3. Bozorgzadeh E, Pasdaran A, Ebrahimi-Najafabadi H. Determination of toxic heavy metals in fish samples using dispersive micro solid phase extraction combined with inductively coupled plasma optical emission spectroscopy. Food Chemistry 2021
  4. doi: 10.1016/j. foodchem.2020.128916 4. Topuz B. Simultaneous spectrometric determination of Cu(II), Co(II), and Ni(II) in pharmaceutical and environmental samples with XAD 4/DMMDTC solid-phase extraction system. Biological Trace Element Research 2020
  5. doi: 10.1007/s12011-019-01930-0 5. Tuzen M, Soylak M, Citak D, Ferreira HS, Korn MGA et al. A preconcentration system for determination of copper and nickel in water and food samples employing flame atomic absorption spectrometry. Journal of Hazardous Materials 2009
  6. 162 (2-3): 1041-1045. doi: 10.1016/j. jhazmat.2008.05.154 6. Tokay F, Bağdat S. Preconcentration of Cu(II), Co(II), and Ni(II) using an optimized enrichment procedure: useful and alternative methodology for flame atomic absorption spectrometry. Applied Spectroscopy 2016
  7. 70 (3): 543-551. doi: 10.1177/0003702815626684 7. Chen H, Du P, Chen J, Hu S, Li S et al. Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid–liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometry. Talanta 2010
  8. 81 (1-2): 176-179. doi: 10.1016/j.talanta.2009.11.054 8. Beltran B, Leal LO, Ferrer L, Cerda V. Determination of lead by atomic fluorescence spectrometry using an automated extraction/ preconcentration flow system. Journal of Analytical Atomic Spectrometry 2015
  9. doi: 10.1039/c4ja00456f 9. Krishna BMV, Ranjit M, Chandrasekaran K, Venkateswarlu G, Karunasagar D. On-line preconcentration and recovery of palladium from waters using polyaniline (PANI) loaded in mini-column and determination by ICP-MS
  10. elimination of spectral interferences. Talanta 2009
  11. doi: 10.1016/j.talanta.2009.06.008 10. Hagarova I,