Which approach is better for the protection of vestibular receptors in cochlear implant surgery: Round window or standard cochleostomy?

Sayfa
187–195
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

All of the patients were evaluated with the Dizziness Handicap Inventory (DHI)and a complete vestibular test battery including the video head impulse test (vHIT), cervical vestibular-evoked myogenic potential(cVEMP), and ocular vestibular-evoked myogenic potential (oVEMP) at one week preoperatively and one month postoperatively.Results: Patients in the RWA group had a statistically significantly better protected vestibular functions and fewer subjective vertigosymptoms in the postoperative period (p

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: This study aims to compare electrode insertion techniques in cochlear implantation (CI) as the standard cochleostomyapproach (SCA) versus the round window approach (RWA) on five vestibular end-organ functions and vertigo in the pre- andpostoperative period.Patients and Methods: In total, 51 patients (22 males, 29 females; mean age 38.2 years; range 16 to 70 years) with normal vestibularfunction and operated with single-sided CI were included in this study between January 2015 and December 2019.
📊
Temel Bulgular & Veri:Of the patients,30 were operated with the RWA and 21 with the SCA.
💡
Sonuç & Katkı:All of the patients were evaluated with the Dizziness Handicap Inventory (DHI)and a complete vestibular test battery including the video head impulse test (vHIT), cervical vestibular-evoked myogenic potential(cVEMP), and ocular vestibular-evoked myogenic potential (oVEMP) at one week preoperatively and one month postoperatively.Results: Patients in the RWA group had a statistically significantly better protected vestibular functions and fewer subjective vertigosymptoms in the postoperative period (p
🔬Tür:Araştırma Makalesi
📍Kapsam:2015 Verileri
⚙️Değişkenler:Alan Parametreleri

Abstract

Objectives: This study aims to compare electrode insertion techniques in cochlear implantation (CI) as the standard cochleostomyapproach (SCA) versus the round window approach (RWA) on five vestibular end-organ functions and vertigo in the pre- andpostoperative period.Patients and Methods: In total, 51 patients (22 males, 29 females; mean age 38.2 years; range 16 to 70 years) with normal vestibularfunction and operated with single-sided CI were included in this study between January 2015 and December 2019. Of the patients,30 were operated with the RWA and 21 with the SCA. All of the patients were evaluated with the Dizziness Handicap Inventory (DHI)and a complete vestibular test battery including the video head impulse test (vHIT), cervical vestibular-evoked myogenic potential(cVEMP), and ocular vestibular-evoked myogenic potential (oVEMP) at one week preoperatively and one month postoperatively.Results: Patients in the RWA group had a statistically significantly better protected vestibular functions and fewer subjective vertigosymptoms in the postoperative period (p

🔖

Bu Makaleye Atıf Yap

KIROĞLU, M., TUNCER, Ü., TARKAN, Ö., DAĞKIRAN, M., ÖZDEMİR, S., SÜRMELİOĞLU, Ö., ONAN, E. (2022). Which approach is better for the protection of vestibular receptors in cochlear implant surgery: Round window or standard cochleostomy?. The Turkish Journal of Ear Nose and Throat, Cilt: 29 - Sayı: 4, 187–195. https://ajindex.com/articles/597918

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Fina M, Skinner M, Goebel JA, Piccirillo JF, Neely JG, Black O. Vestibular dysfunction after cochlear implantation. Otol Neurotol 2003;24:234-42
  2. Krause E, Louza JP, Wechtenbruch J, Gürkov R. Influence of cochlear implantation on peripheral vestibular receptor function. Otolaryngol Head Neck Surg 2010;142:809-13
  3. Batuecas-Caletrio A, Klumpp M, Santacruz-Ruiz S, Benito Gonzalez F, Gonzalez Sánchez E, Arriaga M. Vestibular function in cochlear implantation: Correlating objectiveness and subjectiveness. Laryngoscope 2015;125:2371-5
  4. Manrique-Huarte R, Calavia D, Alvarez-Gomez L, Huarte A, Perez-Fernández N, Manrique M. Vestibulocochlear function after cochlear implantation in patients with Meniere’s disease. J Int Adv Otol 2018;14:18-21
  5. Dagkiran M, Tuncer U, Surmelioglu O, Tarkan O, Ozdemir S, Cetik F, et al. How does cochlear implantation affect five vestibular end-organ functions and dizziness? Auris Nasus Larynx 2019;46:178-85
  6. Hänsel T, Gauger U, Bernhard N, Behzadi N, Romo Ventura ME, Hofmann V, et al. Meta-analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation. Laryngoscope 2018;128:2110-23
  7. Enticott JC, Tari S, Koh SM, Dowell RC, O’Leary SJ. Cochlear implant and vestibular function. Otol Neurotol 2006;27:824-30
  8. Schwab B, Durisin M, Kontorinis G. Investigation of balance function using dynamic posturography under electrical-acoustic stimulation in cochlear implant recipients. Int J Otolaryngol 2010;2010:978594
  9. Devroede B, Pauwels I, Le Bon SD, Monstrey J, Mansbach AL. Interest of vestibular evaluation in sequentially implanted children: Preliminary results. Eur Ann Otorhinolaryngol Head Neck Dis 2016;133:S7-S11
  10. Kubo T, Yamamoto K, Iwaki T, Doi K, Tamura M. Different forms of dizziness occurring after cochlear implant. Eur Arch Otorhinolaryngol 2001;258:9-12
  11. Melvin TA, Della Santina CC, Carey JP, Migliaccio AA. The effects of cochlear implantation on vestibular function. Otol Neurotol 2009;30:87-94
  12. Krause E, Louza JP, Hempel JM, Wechtenbruch J, Rader T, Gürkov R. Effect of cochlear implantation on horizontal semicircular canal function. Eur Arch Otorhinolaryngol 2009;266:811-7
  13. O’Leary MJ, Fayad J, House WF, Linthicum FH Jr. Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 1991;100:695-9. 14. van den Broek P, Huygen PL, Mens LH, Admiraal RJ, Spies T. Vestibular function in cochlear implant patients. Acta Otolaryngol 1993;113:263-5