Dergiler / The European Research Journal / 2018 / Cilt: 4 - Sayı: 4

Three-dimensional turbo spin-echo sequence versus conventional two-dimensional turbo spin-echo sequences in the evaluation of lumbar intervertebral discs

Sayfa
366–373
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

This approach can be used in radiology departmentseither alone or combined with routine MRI for lumbar disc hernias as a diagnostic sequence and an approachto overcome problems.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: The aim of this study was to evaluate the efficacy of a three-dimensional (3D) turbo spin-echo(TSE) sequence for determining lumbar disc protrusions, and to compare the findings with those of conventionaltwo-dimensional (2D) TSE sequences and reveal the interobserver and intermethod agreements of bothsequences.Methods: A total of 127 discs from 84 patients were evaluated by three radiologists.
📊
Temel Bulgular & Veri:Conventional 2D TSEimages and 3D TSE images were independently interpreted with regard to disc pathology and herniation zonesand were scored for the degree of spinal stenosis and lumbar neural foraminal stenosis by the three reviewers.To evaluate the lumbar discs, areas of protrusion or extrusion were classified.
💡
Sonuç & Katkı:This approach can be used in radiology departmentseither alone or combined with routine MRI for lumbar disc hernias as a diagnostic sequence and an approachto overcome problems.
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objectives: The aim of this study was to evaluate the efficacy of a three-dimensional (3D) turbo spin-echo(TSE) sequence for determining lumbar disc protrusions, and to compare the findings with those of conventionaltwo-dimensional (2D) TSE sequences and reveal the interobserver and intermethod agreements of bothsequences.Methods: A total of 127 discs from 84 patients were evaluated by three radiologists. Conventional 2D TSEimages and 3D TSE images were independently interpreted with regard to disc pathology and herniation zonesand were scored for the degree of spinal stenosis and lumbar neural foraminal stenosis by the three reviewers.To evaluate the lumbar discs, areas of protrusion or extrusion were classified. Interobserver and intermethodreliabilities were calculated using Krippendorff’s alpha (Kα) test.Results: Lumbar disc pathology identification was similar between the 2D TSE and 3D TSE sequences.Interobserver agreements were better for 3D TSE than 2D TSE in the evaluation of disc hernias (Kα ratio;0.965 vs. 0.944), herniation zones (Kα ratio; 0.894 vs. 0.847), and foraminal narrowing (Kα ratio; 0.965 vs.0.924). Both 2D and 3D TSE had 100% sensitivity for disc pathologies and spinal stenosis, 81% sensitivityfor herniation zones, and 92.5% sensitivity for foraminal stenosis in only operated patients.Conclusions: The 3D TSE sequence was comparable to conventional magnetic resonance imaging (MRI)sequences in the evaluation of lumbar disc herniation. This approach can be used in radiology departmentseither alone or combined with routine MRI for lumbar disc hernias as a diagnostic sequence and an approachto overcome problems.

🔖

Bu Makaleye Atıf Yap

KIZILGÖZ, V., KARAYOL, S. S., MENDERES, U., YILDIRIM, C. H., SİVRİOĞLU, A. K., AYDIN, H. (2022). Three-dimensional turbo spin-echo sequence versus conventional two-dimensional turbo spin-echo sequences in the evaluation of lumbar intervertebral discs. The European Research Journal, Cilt: 4 - Sayı: 4, 366–373. https://ajindex.com/articles/597744

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (9)

  1. Blizzard DJ, Haims AH, Lischuk AW, Arunakul R, Hustedt JW, Grauer JN, et al. 3D-FSE isotropic MRI of the lumber spine novel application of an existing technology. J Spinal Disord Tech 2015;28:152- 7. Tins B, Cassar-Pullicino V, Haddaway M, Nachtrab U. Threedimensional sampling perfection with application-optimised contrasts using a different flip angleevolutions sequence for routine imaging of the spine: preliminary experience. Br J Radiol 2012;85:e480-9. Mahmutyazicioglu K, Ozdemir H, Savranlar A, Ozer T, Erdem O, Erdem Z, et al. Comparison of three-dimensional gradient echo, turbo spin echo and steady-state gradient echo sequences in axial MRI examination of the cervical spine. Tani Girisim Radyol 2003;9:432-8.
  2. Baskaran V, Pereles FS, Russell EJ, Georganos SA, Shaibani A, Spero KA, et al. Myelographic MR imaging of the cervical spine with a 3D true fast imaging with steady-state precession technique: initial experience. Radiology 2003;227:585-92.
  3. Meindl T, Wirth S, Weckbach S, Dietrich O, Reiser M, Schoenberg SO. Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences. Eur Radiol 2009;19:713-21.
  4. Held P, Fründ R, Seitz J, Nitz W, Haffke T, Hees H. Comparison of 2-D turbo spin echo and 3-D gradient echo sequences for the detection of the trigeminal nerve and branches anatomy. Eur J Radiol 2001;37:18- 25. Ramlı N, Cooper A, Jaspan T. High resolution CISS imaging of the spine. Br J Radiol 2001;74:862-73.
  5. Murakami N, Matsushima T, Kuba H, Ikezaki K, Morioka T, Mihara F, et al. Combining steady-state constructive interference and diffusionweighted magnetic resonance imaging in the surgical treatment of epidermoid tumours. Neurosurg Rev 1999;22:159-62.
  6. Yousry I, Camelio S, Schmid UD, Horsfield MA, Wiesmann M, Brückmann H, et al. Visualization of cranial nerves 1-12: Value of 3D CISS and T2W FSE sequences. Eur Radiol 2000;10:1061-7.
  7. Jensen MC, Brant-Zawadzki MN, Obuchowski N, Modic MT, Malkasian D, Ross JS. Magnetic resonance imaging of the lumbar spine in people without back pain. N Engl J Med 1994;331:69-73.
  8. Lee S, Lee JW, Yeom JS, Kim KJ, Kim HJ, Chung SK, et al. A practical MRI grading system for lumbar foraminal stenosis. Am J Roentgenol 2010;194:1095-8.
  9. Aydin H, Kızılgöz V, Hekimoğlu B. Compared with the conventional MR imaging, do the constructive interference steady state sequence and diffusion weighted imaging ai